PubMed Health⌕ Search

Biomedical subjects

E Y Hwang

Publications and source records attributed to E Y Hwang.

3 recordsLinked to original sources

Reliability of intraoperative transesophageal echocardiography during Tetralogy of Fallot repair.

UNLABELLED: There is limited information available concerning the accuracy of intraoperative transesophageal echocardiography (TEE) in predicting the extent of residual abnormalities after recovery from surgical repair of tetralogy of Fallot. Therefore, we investigated differences between the results of final postbypass TEE and those of postrecovery (mean, 6 days after surgery) transthoracic echocardiography in a total of 28 consecutive pediatric patients who underwent repair of tetralogy of Fallot with biplane or multiplane TEE. Both postbypass and postrecovery echocardiographic examinations included measurements of the right ventricle (RV)-main pulmonary artery (PA) and the main PA-branch PA peak instantaneous gradients, the degree of pulmonary valvar insufficiency, and color Doppler interrogation of the ventricular septum for residual defects. The RV-main PA gradient did not change significantly: 15 +/- 13 vs 18 +/- 14 mmHg (postbypass versus postrecovery, mean +/- SD). None of the patients had a decrease of > or = 10 mmHg; and only one patient had an increase of > or = 15 mmHg. There also was no change in the degree of pulmonary insufficiency (3.0 +/- 1.2 versus 3.1 +/- 1.1, using a scale of 0 to 4). Only one of the seven very small (< or = 2 mm) residual ventricular septal defects was not discovered during postbypass TEE. However, postrecovery transthoracic echocardiography detected significant branch PA stenosis (peak gradient, > or = 15 mmHg) in five patients (18%) that was not detected during postbypass TEE (P < 0.03). Of the branch PA stenoses that were not detected during TEE, four were left and one was right. CONCLUSIONS: Postbypass TEE after tetralogy of Fallot repair reliably predicts residual postrecovery hemodynamic abnormalities, except for branch PA stenosis.

Adolescent↗

Variables controlling contrast generation in a urinary bladder model.

An ultrasound system has been developed to generate microbubbles in vivo for use as ultrasound contrast agent. Possible application include diagnosis of reflux in the urinary tract. In experiments designed to elucidate the contrast microbubble generation process, acoustic bursts (at 1.8 MHz, 125 ms) were propagated through a latex rubber balloon, modeled after a rabbit urinary bladder, containing fluids of various air and carbon dioxide saturations and concentrations of cavitation nuclei (0.198-micron-diam polystyrene particles). The peak rarefactional pressure threshold for contrast microbubble generation, as visualized with a diagnostic ultrasound system, decreased approximately a factor of 2 for increasing particle concentration from 10(8) to 10(10) particles/cc, with the lowest threshold of 5.24 MPa. For samples with gas saturations below 50% and 10(10) particles/cc, the average thresholds were at least twice as high as those of more saturated fluids (with mean threshold for saturated fluids of 6.45 MPa), and samples containing CO2 had considerably lower thresholds than respective under-saturations in air. At a fixed pressure amplitude, echogenicity tended to increase with both increasing particle concentration and gas saturation; this was more favorable for samples containing CO2. Even in a restricted-nuclei environment such as the urinary bladder, generation of vaporous cavitation should be possible; however, subsequently, abundant gas is needed to grow vaporous bubbles to persistent and imageable sizes, to assist in the diagnosis of urinary reflux.

Animals↗