PubMed Health⌕ Search

Biomedical subjects

E da Cruz

Publications and source records attributed to E da Cruz.

5 recordsLinked to original sources

Successful use of a new Amplatzer Vascular plug for percutaneous closure of a large aortopulmonary collateral artery in a pulmonary atresia with ventricular septal defect prior to complete repair.

We report the case of a 14 year-old girl with a pulmonary atresia with VSD and multiple aortopulmonary collaterals who underwent a successful complementary occlusion of a large collateral vessel using an Amplatzer vascular plug after a previously failed attempt of occlusion with a coil. The percutaneous procedure, performed from the femoral artery before the complete surgical repair, provided an immediate closure of the vessel. This new device is safe and effective for the occlusion of aortopulmonary collaterals, specifically if of large dimensions.

Adolescent↗

A "friendly" system for pericardial drainage.

We describe an alternative to the water-seal system, suitable for drainage of pericardial and eventually pleural effusions, which has been shown to be safe, effective, not painful, and rather "friendly", providing patients with a smoother clinical course.

Cardiac Catheterization↗

[Closure of patent ductus arteriosus by video thoracoscopy in 282 children].

Closure of patent ductus arteriosus by video thoracoscopy is a standardised procedure. The authors report their experience of closure of patent ductus arteriosus by video-thoracoscopy from May 1991 to December 1995. The series included 282 patients divided into 3 groups according to age: under 6 months (78 patients, 27.6%), from 6 months to 4 years (135 patients, 42.88%) and over 4 years of age (69 patients, 24.6%) with an average weight of 12.6 kg (range: 1.2 to 65 kg). Symptomatic pulmonary hypertension was observed in 39 cases and 9 children had associated intracardiac malformations (ostium secundum: 3; ventricular septal defect: 5; abnormal pulmonary venous drainage: 1) which were not corrected. The technique consisted of placing two titanium clips in position under video-thoracoscopy to close the ductus. An echo performed immediately afterwards confirmed closure of the ductus. The main complications were: persistence of a shunt (4 cases) at the beginning of our experience requiring immediate reoperation by video-thoracoscopy in 3 cases and by thoracotomy in one case; left recurrent laryngeal nerve palsy in 6 cases (2.1%) with regression in 5 and persistence in one case; one case of postoperative chylothorax which regressed rapidly. There were no fatalities or haemorrhages and no blood transfusions were required in this series. The average operating time was 20 +/- 15 minutes and the duration of hospital stay around 48 hours when the patients were over 6 months old and 72 hours when less than 6 months of age. Video-thoracoscopic closure of patent ductus arteriosus is rapid, safe, economical, it provides excellent results and may be used in children of all ages.

Age Factors↗