PubMed Health⌕ Search

Biomedical subjects

Eberhard Grube

Publications and source records attributed to Eberhard Grube.

At least 19 recordsLinked to original sources

Predictors of restenosis after treatment of bifurcational lesions with paclitaxel eluting stents: a multicenter prospective registry of 150 consecutive patients.

OBJECTIVES: The aim of the study was the assessment of the clinical, angiographic and procedural characteristics correlated with freedom from adverse events at 1 year in a real life setting of consecutive bifurcation lesions. BACKGROUND: Even if stent implantation has shown to be superior to conventional balloon angioplasty in most coronary lesions, bifurcation treatment with stent implantation both in main and in side branch (SB) still raises controversy. METHODS: We reviewed the results obtained in a prospective multicenter registry of 150 patients with 158 bifurcation lesions involving a SB of sufficient diameter to be treated, if necessary, with a polymer based paclitaxel eluting stent (PES, TAXUS). Two stents were used in 118 lesions (74.7%). Final kissing balloon inflation was performed in 87/118 lesions (73.7%) and in 30/40 lesions (75.0%) of the 2 and 1 stent group respectively. RESULTS: At 1-year clinical follow-up we observed 4 stent thromboses, all involving the SBs of the 2 stents group (2.7%). Unlike previous reports, revascularization involved the main vessel in the majority of patients (21/150, 14.0%). After an exploratory multivariable analysis the only parameter predictive of target lesion revascularization (TLR) (HR 0.52; CI 95% 0.11-0.86; p = 0.02) and target vessel revascularization (TVR) (HR 0.47; CI 95% 0.14-0.90; p = 0.03) was postprocedural main branch minimal lumen diameter (MB-MLD). CONCLUSIONS: In a real life setting of consecutive bifurcation lesions, thrombosis rate, concentrated in the SB and the 2-stents group, and need for target lesion revascularization remain higher than in less complex lesion subgroups treated with PES. No differences in immediate success and TLR were observed between 2 stents and 1 stent groups. The frequently observed suboptimal stent expansion and final MB-MLD predict 1 year revascularization.

Aged↗

Network analysis of human in-stent restenosis.

BACKGROUND: Recent successes in the treatment of in-stent restenosis (ISR) by drug-eluting stents belie the challenges still faced in certain lesions and patient groups. We analyzed human coronary atheroma in de novo and restenotic disease to identify targets of therapy that might avoid these limitations. METHODS AND RESULTS: We recruited 89 patients who underwent coronary atherectomy for de novo atherosclerosis (n=55) or in-stent restenosis (ISR) of a bare metal stent (n=34). Samples were fixed for histology, and gene expression was assessed with a dual-dye 22,000 oligonucleotide microarray. Histological analysis revealed significantly greater cellularity and significantly fewer inflammatory infiltrates and lipid pools in the ISR group. Gene ontology analysis demonstrated the prominence of cell proliferation programs in ISR and inflammation/immune programs in de novo restenosis. Network analysis, which combines semantic mining of the published literature with the expression signature of ISR, revealed gene expression modules suggested as candidates for selective inhibition of restenotic disease. Two modules are presented in more detail, the procollagen type 1 alpha2 gene and the ADAM17/tumor necrosis factor-alpha converting enzyme gene. We tested our contention that this method is capable of identifying successful targets of therapy by comparing mean significance scores for networks generated from subsets of the published literature containing the terms "sirolimus" or "paclitaxel." In addition, we generated 2 large networks with sirolimus and paclitaxel at their centers. Both analyses revealed higher mean values for sirolimus, suggesting that this agent has a broader suppressive action against ISR than paclitaxel. CONCLUSIONS: Comprehensive histological and gene network analysis of human ISR reveals potential targets for directed abrogation of restenotic disease and recapitulates the results of clinical trials of existing agents.

ADAM Proteins↗

Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study.

BACKGROUND: The morbidity and mortality of surgical aortic valve replacement are increased in elderly patients with multiple high-risk comorbid conditions. Therefore, a prospective, single-center, nonrandomized study was performed in high-risk patients with aortic valve disease to evaluate the feasibility and safety of percutaneous implantation of a novel self-expanding aortic valve bioprosthesis (CoreValve). METHODS AND RESULTS: Symptomatic high-risk patients with an aortic valve area <1 cm2 were considered for enrollment. CoreValve implantation was performed under general anesthesia with extracorporeal support using the retrograde approach. Clinical follow-up and transthoracic echocardiography were performed after the procedure and at days 15 and 30 after device implantation to evaluate short-term patient and device outcomes. A total of 25 patients with symptomatic aortic valve stenosis (mean gradient before implantation, 44.2+/-10.8 mm Hg) and multiple comorbidities (median logistic EuroScore, 11.0%) were enrolled. Device success and procedural success were achieved in 22 (88%) and 21 (84%) patients, respectively. Successful device implantation resulted in a marked reduction in the aortic valve gradients (mean gradient after implantation, 12.4+/-3.0 mm Hg; P<0.0001). The mean aortic regurgitation grade was unchanged. Major in-hospital cardiovascular and cerebral events occurred in 8 patients (32%), including mortality in 5 patients (20%). Among 18 patients with device success surviving to discharge, no adverse events occurred within 30 days after leaving the hospital. CONCLUSIONS: Percutaneous implantation of the self-expanding CoreValve aortic valve prosthesis in high-risk patients with aortic stenosis with or without aortic regurgitation is feasible and, when successful, results in marked hemodynamic and clinical improvement.

Aged↗

Testing prospectively the effectiveness and safety of paclitaxel-eluting stents in over 1000 very high-risk patients: design, baseline characteristics, procedural data and in-hospital outcomes of the multicenter Taxus in Real-life Usage Evaluation (TRUE) Study.

BACKGROUND: Paclitaxel-eluting stents (PES) have been proved effective in randomized trials enrolling highly selected patients. Yet, given the uncertainty concerning results of PES implantation in very high-risk patients and lesions, we designed a prospective multicenter registry, the Taxus in Real-life Usage Evaluation (TRUE) Study. STUDY DESIGN, PATIENT CHARACTERISTICS AND IN-HOSPITAL OUTCOMES: Consecutive patients undergoing PES implantation were enrolled provided that the target lesion treated with PES was an unprotected left main (ULM), a true bifurcation, a chronic total occlusion (CTO), a long lesion (>28 mm), located in a small vessel (<2.75 mm), or the patient had diabetes mellitus. Clinical events will be adjudicated at 1, 7 and 12 months, with 4- to 8-month angiographic follow-up. The primary end-point will be the 7-month occurrence of major adverse cardiovascular events (MACE, i.e. the composite of cardiac death, non-fatal myocardial infarction [MI], coronary artery bypass grafting [CABG] and percutaneous target vessel revascularization [TVR]). To date, patient enrollment has been completed reaching the target of 1065 subjects. These included 322 (30.2%) diabetics, 115 (10.8%) subjects undergoing PES implantation for ULM, 229 (21.5%) in a bifurcation, 191 (17.9%) in a CTO, 430 (40.4%) in a small vessel, and 289 (27.1%) in a long lesion. An average of 1.5+/-0.6 vessels and 2.0+/-1.0 lesions were treated per patient, with 2.0+/-1.2 PES implanted per patient, and a 46+/-30 mm total PES length per patient. In-hospital MACE occurred in 39 (3.7%) patients, with 2 (0.2%) cardiac deaths, 32 (3.0%) MI, 5 (0.5%) TVR, no CABG, and 4 (0.4%) acute stent thromboses. IMPLICATIONS: Despite the availability of randomized trials, only carefully designed and prospective registries can provide timely and accurate assessment of the risk-benefit profile of PES in very high-risk patients. Indeed, the TRUE Study, including as much as 115 ULM and 229 bifurcation interventions, should give important insights into the outcome of PES in such an unprecedented and challenging context.

Combined Modality Therapy↗

Angiographic results of the first human experience with the Biolimus A9 drug-eluting stent for de novo coronary lesions.

This report describes angiographic findings of the first-in-human evaluation of the Biolimus A9 drug-eluting stent (Biolimus stent) in the treatment of noncomplex coronary lesions. In total, 120 patients with 122 de novo coronary lesions (2.75- to 4.00-mm vessels, < or = 24-mm lesion length) were prospectively randomized in a 2:1 ratio to receive the Biolimus stent (n = 80, 82 lesions) or the control uncoated stent (n = 40). Baseline lesion and angiographic characteristics were similar between groups. At 6-month follow-up, late lumen loss was significantly decreased with the Biolimus stent in the stent (0.26 +/- 0.43 vs 0.74 +/- 0.45 mm, p < 0.001) and in the segment (0.14 +/- 0.45 vs 0.40 +/- 0.41 mm, p = 0.004). In-stent restenosis was 3.9% in the Biolimus stent group versus 7.7% in the control group (p = 0.40). There was no exaggerated hyperplasia at the proximal and/or distal edge of the stent.

Blood Vessel Prosthesis Implantation↗

Effect of everolimus-eluting stents in different vessel sizes (from the pooled FUTURE I and II trials).

The everolimus-eluting stent (EES) has been shown to significantly decrease neointimal proliferation at 6 months compared with the bare metal stent (BMS) in patients with de novo coronary lesions. We report mid-term outcomes based on different vessel sizes in the combined FUTURE I and II trials. In the prospective, randomized, FUTURE I trial (single center) and expanded FUTURE II trial (multicenter), 106 patients (107 lesions) were randomized to EESs (n = 49 lesions) or BMSs (n = 58 lesions). Patients were categorized into 3 groups based on preprocedure reference diameter as assessed by quantitative coronary angiography (small vessel < 2.75 mm, medium vessel 2.75 to 3.25 mm, and large vessel > 3.25 mm). At 6-month follow-up, EESs decreased in-stent late lumen loss (decreased rate range of 78% to 94%), resulting in significantly larger minimum lumen area as assessed by intravascular ultrasound (increased range of 34% to 42%) compared with the BMS across all vessel sizes. There were no cases of in-stent restenosis with EESs at any vessel size but 8 cases with BMSs (5 in small vessels). No stent thrombosis, aneurysm formation, or late stent incomplete apposition was observed in any group. The EES appears to be effective for treatment of de novo coronary lesions in decreasing neointimal proliferation at 6-month follow-up compared with BMSs, regardless of vessel size.

Aged↗

Drug-eluting stents in the treatment of intermediate lesions: pooled analysis from four randomized trials.

OBJECTIVES: To address the safety and efficacy of drug-eluting stents (DES) in the treatment of intermediate lesions, we performed a pooled analysis of four randomized DES versus bare-metal stent (BMS) trials and assessed outcomes among patients with intermediate lesions. BACKGROUND: Before the introduction of DES, intermediate coronary lesions were commonly managed based on physiologic or anatomic assessment of lesion severity. The DES may challenge this paradigm. METHODS: The study population involved 167 of 2,478 randomized patients (6.7%) with intermediate lesions (diameter stenosis <50% [mean 44%] by quantitative coronary angiography) from the Sirolimus-coated Bx Velocity Balloon Expandable Stent in the Treatment of Patients with De Novo Coronary Artery Lesions (SIRIUS), TAXUS-IV, and the First and Second First Use to Underscore Restenosis Reduction with Everolimus (FUTURE-I and -II) trials. End points examined included early (in-hospital and 30-day) and late (1-year) major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), stent thrombosis, and follow-up angiographic restenosis. RESULTS: Patients with intermediate lesions randomized to DES versus BMS had low rates of 30-day MACE (1.1% vs. 4.0% respectively; p = 0.22). At one-year follow-up, patients treated with DES versus BMS had similar rates of cardiac death (0% vs. 2.7%, respectively; p = 0.11) and MI (3.4% vs. 5.4%; p = 0.49) but markedly lower rates of TVR (3.4% vs. 20.3%; p = 0.0004), MACE (5.6% vs. 25.4%; p = 0.0003), and binary angiographic restenosis (1.8% vs. 34.0%; p < 0.0001). No patient in either group developed stent thrombosis. CONCLUSIONS: Compared with BMS, treatment of intermediate lesions with DES appears safe and results in a marked reduction in clinical and angiographic restenosis. The efficacy of DES may require a reevaluation of current treatment paradigms for intermediate lesions.

Coronary Restenosis↗

Comparison of ticlopidine vs. clopidogrel in addition to aspirin after paclitaxel-eluting stent implantation: insights from the TRUE (Taxusin Real-life Usage Evaluation) Study.

Thienopyridines and aspirin are beneficial in patients undergoing bare-metal stent implantation, and aspirin and clopidogrel treatment have also been proved effective after drug-eluting stent (DES) implantation. However, despite the common substitution of clopidogrel with ticlopidine because of cost or patient intolerance, there are no data on the comparison of ticlopidine vs. clopidogrel after DES implantation. We hereby compare ticlopidine vs. clopidogrel after paclitaxel-eluting stent implantation in subjects enrolled in the prospective multicenter Taxus in Real-life Usage Evaluation (TRUE) Study. Across the 505 analyzed patients (112 treated with ticlopidine and 393 with clopidogrel), similar rates of early and mid-term (7 months) adverse thrombotic events were found with either antiplatelet regimen, with the notable exception of 2 cases of late stent thrombosis in patients who had prematurely withdrawn ticlopidine treatment just 3 months after the procedure. These findings thus support the overall safety and effectiveness of ticlopidine after DES implantation, and also confirm the increased risk of late thrombosis when premature withdrawal of thienopyridines occurs.

Aspirin↗

Acute and long-term outcomes of the novel side access (SLK-View) stent for bifurcation coronary lesions: a multicenter nonrandomized feasibility study.

OBJECTIVE: To evaluate technical feasibility and procedural safety of SLK-View stent for treating bifurcation lesions. BACKGROUND: Percutaneous treatment of coronary bifurcation lesions represents a technical challenge. Several stenting techniques and dedicated devices have proven unsuccessful, with high rates of side branch occlusion at index procedure and follow-up. METHODS: Eighty one patients with 84 de novo coronary artery lesions involving a major side branch underwent SLK-View (Advanced Stent Technologies, Inc., Pleasanton, CA) stent implantation with subsequent kissing balloon post dilatation. SLK-View stent is a new scaffolding device incorporating a side aperture that allows access to the side-branch of a bifurcation after deployment of the stent in main vessel. All patients underwent angiographic follow-up at 6 months. Procedural, in-hospital, and 6-month follow-up outcomes were examined. RESULTS: The lesions were located in left main (n = 11), left anterior descending (n = 50), left circumflex (n = 8), right coronary artery (n = 7), and 1 ramus intermedius. The most frequent lesions (44.1%) were true bifurcations. Successful stent delivery to bifurcation was accomplished in 82/84 of the cases (97.6%). Technical success was obtained in 99 and 94% of main vessel and side branches, respectively. Stenting in side-branch was performed in 21 lesions (25%). Side-branches were accessed effectively in 100% of bifurcations postprocedurally. Binary restenosis rate at 6-month follow-up was 28.3% and 37.7% for main vessel and side-branch, respectively. TLR rate at 6-month follow-up was 21% and CABG rate of 6%. CONCLUSION: In this consecutive multicenter series of patients with coronary bifurcation lesions, this novel side-branch access stent proved feasible, with a high procedural success rate, while maintaining side-branch access.

Angioplasty, Balloon↗

Influence of plaque calcium on neointimal hyperplasia following bare metal and drug-eluting stent implantation.

OBJECTIVES: To examine the influence of vessel wall calcium on neointimal hyperplasia (NIH) following bare metal stent (BMS) and drug-eluting stent (DES) implantation. BACKGROUND: While procedural complications with coronary stenting in calcified lesions are well reported, little is known about subsequent NIH on plaque calcium following either BMS or DES implantation. METHODS: In the Study to COmpare REstenosis Rate between QueST and QuaDDS-QP2 (SCORE) trial, 6 months follow-up volumetric intravascular ultrasound data were available for 41 lesions (BMS, 19; DES, 22). NIH thicknesses on superficial, deep, and noncalcified plaque were calculated at every 0.5 mm intervals over the stented segment. Calcified and less-calcified cross-sections were defined as those containing arcs of plaque calcium > or = 90 degrees and < 90 degrees , respectively. RESULTS: In BMS, mean NIH thickness on both superficial (0.24 +/- 0.23 mm) and deep calcium (0.25 +/- 0.21 mm) was significantly smaller than that of noncalcified plaque (0.31 +/- 0.22 mm) (P < 0.0005). NIH area was significantly smaller in calcified cross-sections compared to less-calcified cross-sections (2.1 +/- 1.2 mm2 vs. 3.1 +/- 1.9 mm2, P < 0.0001). While in contrast, in DES, mean NIH thickness was similar, irrespective of the presence or location of calcium (0.03 +/- 0.05 mm vs. 0.03 +/- 0.06 mm vs. 0.03 +/- 0.05 mm, superficial vs. deep vs. noncalcified plaque, P = NS). NIH area was also similar between calcified and less-calcified cross-sections (0.3 +/- 0.6 mm2 vs. 0.3 +/- 0.6 mm2, P = NS). CONCLUSIONS: These results suggest that while plaque calcium may influence NIH following BMS implantation, NIH suppression using DES does not appear to be affected by the presence or location of calcium.

Bridged-Ring Compounds↗

Use of Taxus polymer-coated paclitaxel-eluting stents for treatment of in-stent restenosis in real world patients: results of clinical and angiographic follow-up at six months in a single-center registry.

OBJECTIVE: To evaluate the safety and efficacy of Taxus paclitaxel-eluting stents in a real world group of unselected patients with coronary in-stent restenosis (ISR) lesions. METHODS: This is a prospective single-center registry of a consecutive series of 94 patients with 104 ISR lesions, without previous brachytherapy, over a period of 1 year. Quantitative coronary angiographic analyses were performed at baseline and at 6-month angiographic follow-up. Clinical follow-up were obtained at 6 months. RESULTS: Pre-intervention mean reference vessel diameter was 2.62 +/- 0.50 mm and mean lesion length was 13.95 +/- 6.78 mm. Baseline ISR patterns were mostly either Type I focal (32.7%) or Type II diffuse intrastent (48.1%). At 6-month angiographic follow-up, the in-stent and in-segment binary restenosis was 3.8% (4/105) and 7.6% (8/105) respectively, and the in-stent and in-segment late loss was 0.30 +/- 0.50 mm and 0.57 +/- 0.54 mm, respectively. Seven of these eight restenosed lesions had a diffuse or proliferative ISR pattern prior to intervention. Lesions that restenosed had longer mean stent length per lesion (37.3 mm vs. 22.5 mm in nonrestenosed group; P = 0.001) and more likely to have had a pattern of total occlusion pre-intervention (25.0% vs. 3.1% in nonrestenosed group; P = 0.046). At 6-month clinical follow-up, the MACE rate was 8.5% and target lesion revascularization rate was 7.4%. There was no death but subacute stent thrombosis occurred in 1 patient (1.1%) at 3 days after intervention. CONCLUSIONS: Paclitaxel-eluting Taxus stent for the treatment of ISR effectively suppresses recurrent neointimal proliferation, and was safe and efficacious at 6-month follow-up.

Aged↗

[Percutaneous aortic valve replacement].

Surgical aortic valve replacement has been the gold standard for treatment of symptomatic aortic valve disease. However, the success of this approach depends on various patient- and situation-specific risk predictors; thus, the perioperative mortality can reach up to 50%. Percutaneous valve replacement might offer a new less invasive alternative. Since 2002, a balloon-expandable valve prosthesis is under evaluation in symptomatic high-risk patients with aortic valve stenosis. After modifications of both the implantation technique as well as the design of the prosthesis, procedural success rates of > 75% and adverse event rates of < 20% at 30-day follow-up have been reported. A new alternative to this approach is the self-expanding valve prosthesis. The recently reported First-in-Man Study demonstrated the feasibility of this technique. However, the strict inclusion criteria for both procedures limit the number of potential candidates. New devices are currently under development, which will allow for a broader use of percutaneous valve replacement in the near future.

Angiography↗

Mechanisms of lumen narrowing of saphenous vein bypass grafts 12 months after implantation: an intravascular ultrasound study.

BACKGROUND: Previous long-term (>1 year) studies have suggested that saphenous vein bypass grafts (SVGs) undergo vascular remodeling similar to native coronary arteries. However, early morphologic stages of SVG remodeling have not been characterized in vivo. METHODS: Thirty SVGs were studied 12 months after implantation using an intravascular ultrasound automated pullback system. Intravascular ultrasound images were analyzed between 10 and 60 mm from the tip of the guide. Lumen area (LA), intima area (IA), and vessel area (VA, defined as the area within the outer border of a hypoechoic intimal layer) were computed at 3 cross sections: the minimum LA (MLA) site and the proximal and distal reference sites. Area changes (Delta) were calculated as the MLA site minus the average of the reference sites. RESULTS: In this cohort, 70% of the MLA sites had a smaller VA than the average references. On average, MLA sites had significantly smaller VA (9.7 +/- 2.9 vs 10.7 +/- 3.2 mm2, P < .01) and larger IA (2.5 +/- 2.1 vs 1.2 +/- 1.3 mm2, P < .01) than at the reference sites. The relative contribution of DeltaVA (-1.0 +/- 1.4 mm2) and DeltaIA (1.3 +/- 1.3 mm2) to lumen compromise (-2.3 +/- 1.4 mm2) were 43% and 57%, respectively. On the other hand, simple linear regression analysis revealed a significant positive correlation between DeltaIA and DeltaVA (y = -1.7 + 0.52x, r = 0.50, P < .01). CONCLUSIONS: Within the first year, the mechanism of lumen compromise in SVG is a combination of negative remodeling and intimal hyperplasia. Positive remodeling is seen in a minority of cases. However, the direction and extent of remodeling correlated with change in intimal thickness.

Aged↗

FX MiniRAIL catheter usage for treatment of de novo complex coronary lesions: results from the "OFFAR".

INTRODUCTION: Gradual prolonged balloon angioplasty may cause less arterial trauma, higher success rates, and fewer complications than conventional angioplasty (POBA). The OFFAR aimed to determine the safety and effectiveness of the FX MiniRAIL (FX) catheter, used with a slow, stepwise inflation protocol. METHODS AND RESULTS: From June to December 2003, 181 consecutive patients (age 61.9 +/- 10.6 years) with de novo coronary artery lesions (n = 217) were treated by FX and stent implantation in 11 European centers. Fifty-one patients (28.2%) had diabetes, and 70 (38.7%) had prior MI; 73 patients (40.3%) presented with stable angina and 85 (47.0%) with unstable angina. Fifty-five lesions (25.3%) were in small vessels (<2.5 mm), 40 (18.6%) were highly calcific, and 133 (62%) were long lesions (>18 mm). Stenosis resolution pressure was 7.17 +/- 4.2 atm; inflation time was 116.5 +/- 54.6 seconds. FX technical success (residual stenosis <50% post-FX) was obtained in 191 lesions (88.0%), and FX optimal success (residual stenosis <20% post-FX) in 117 (54.9%). Dissection was observed in 34 lesions (15.9%), 27 (79.3%) of which were type A or B. No coronary ruptures occurred. Nine (5.0%) in-hospital events occurred, all non-Q-wave MI. During 6-month follow-up, major adverse clinical events occurred in 14.4% of cases (n = 26; 3 cardiac deaths, 1 Q-wave MI, 2 non-Q-wave MI, 3 CABG, and 17 re-PTCA). CONCLUSION: The results of the OFFAR suggest that FX utilization for treatment of de novo complex coronary lesions is safe and effective.

Angioplasty, Balloon, Coronary↗

An overview of the TAXUS Express, paclitaxel-eluting stent clinical trial program.

Restenosis remains a problem following percutaneous coronary intervention in patients with coronary artery disease. Drug-eluting stents (DES), which combine mechanical and pharmacologic properties, have been shown to prevent or reduce neointimal growth after deployment. This review describes the TAXUS paclitaxel-eluting stent clinical trial expansion program (TAXUS Express, Boston Scientific, Natick, MA). This program comprises the largest data set of randomized controlled trials (RCTs) of DES to date, with over 6,200 patients enrolled since 2000. The program includes treatment of de novo lesions, as well as higher-risk lesion and patient populations. In this review, we discuss the results from the TAXUS family of randomized clinical trials, and compare the findings with data from TAXUS registries. The data from the randomized clinical trials suggest that the paclitaxel-eluting stent provides consistent and durable benefits across multiple lesion and patient types. Evidence from peri-and post-approval registries, where patient populations are more heterogeneous than those eligible and included in the RCTs, corroborate these findings, with overall low rates of cardiac events, including reinterventions.

Angioplasty, Balloon, Coronary↗

High-frequency mechanical vibration to recanalize chronic total occlusions after failure to cross with conventional guidewires.

BACKGROUND: Crossing chronic total occlusions (CTO) of coronary arteries continues to challenge interventional cardiologists. A clinical study was undertaken in four European centers to examine the feasibility of using the new CROSSER system that utilizes high-frequency mechanical vibration to penetrate atherosclerotic plaque material to cross CTOs in patients where conventional guidewire techniques had failed. The objective of the study was to determine whether the CROSSER system could safely cross such CTOs. PATIENTS AND METHODS: A total of 55 CTO lesions in 53 patients were treated in two clinical phases: (1) Phase 1 feasibility study (30 CTOs), with a primary focus on device safety; and (2) Phase 2 pivotal study (25 CTOs) using an improved version of the device, with a primary focus on effectiveness. RESULTS: The primary endpoint of device efficacy and the secondary endpoint of clinical success were both 76% (19 of 25) in the pivotal study phase. No major adverse cardiac events of death, Q-wave myocardial infarction or target lesion revascularization (by either coronary artery bypass graft surgery or percutaneous coronary intervention) were observed through 30-day follow up. No coronary perforation or pericardial tamponade occurred. CONCLUSIONS: The CROSSER system is a safe device that can cross many occlusions after a conventional guidewire failure. With additional refinement and improvements to the device, this success rate could be further increased.

Adult↗

Evaluation of a new polymer-coated paclitaxel-eluting stent for treatment of de novo lesions: six-month clinical and angiographic follow-up results of the APPLAUSE trial.

BACKGROUND: This trial assesses the safety and efficacy of the PicoElite stent (amg International GmbH, Raesfeld-Erle, Germany), a new paclitaxel-eluting polymer-based stent. METHODS: This is a first-in-man, single-center pilot trial that randomized 30 patients with 35 de novo coronary lesions in a 2:1 proportion to either the paclitaxel-eluting PicoElite stent (PES group: 20 patients with 24 lesions) or the bare metal ArthosPico stent (BMS group: 10 patients with 11 lesions). RESULTS: Baseline characteristics were similar in both groups, apart from younger patients in the PES group (mean age 63.5 years vs. 71.7 years in the BMS group; p = 0.032) and shorter lesion length in the PES group (9.56 mm vs. 14.25 mm in the BMS group; p = 0.02). In both groups, there was no difference in the primary endpoint of major adverse cardiac events (MACE) at 30-day follow up. There was a nonsignificant trend towards lower 6-month MACE and target lesion revascularization (TLR) rates in the PES group (10.5% PES vs. 40.0% in the BMS group for both; p = 0.143), and no stent thrombosis in the PES group. At 6-month angiographic follow up, the PES group demonstrated a significantly reduced in-stent binary restenosis rate (5.0% vs. 40.0%; p = 0.031), in-stent late loss (0.47 mm vs. 1.10 mm; p = 0.004), and in-segment late loss (0.72 mm vs. 1.16 mm; p = 0.016) as compared to the BMS group. CONCLUSIONS: The 6-month results of the APPLAUSE study demonstrate the safety and efficacy of the paclitaxel-eluting PicoElite stent for de novo lesions, with a significant reduction in late loss and a trend towards less TLR compared to a bare metal control.

Adult↗

Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial: support for the use of drug-eluting stents in contemporary clinical practice.

BACKGROUND: Intracoronary polymer-based stent delivery of paclitaxel has been shown to be effective in reducing restenosis in simple coronary lesions, but the evidence base for contemporary use in longer, more complex coronary stenoses is lacking. METHODS AND RESULTS: TAXUS VI is a prospective, multicenter, double-blind, randomized trial assessing clinical and angiographic outcomes of the TAXUS Moderate Release paclitaxel-eluting stent in the treatment of long, complex coronary artery lesions. Four hundred forty-eight patients at 44 sites were randomized (1:1) between a drug-eluting TAXUS Express2 and an uncoated Express2 control stent. Per protocol, the 9-month follow-up included an angiographic reevaluation in all patients. The primary end point was the rate of target-vessel revascularization 9 months after the study procedure; secondary end points included the rate of target-lesion revascularization and binary restenosis at follow-up. Mean lesion length in the study was 20.6 mm, with a mean stent-covered length of 33.4 mm. Of all lesions, 55.6% were classified as complex lesions (type C of the AHA/ACC classification). At 9 months, target-vessel revascularization was 9.1% in the TAXUS group and 19.4% in the control group (P=0.0027; relative reduction, 53%). Target-lesion revascularization was reduced from 18.9% to 6.8%, respectively (P=0.0001). The incidence of major adverse cardiac events was similar in the 2 groups, 16.4% and 22.5% in TAXUS and control, respectively (P=0.12), including comparable rates for acute myocardial infarction. Binary restenosis in the stented area was reduced from 32.9% in the control group to 9.1% in the TAXUS patients (P<0.0001). CONCLUSIONS: The finding that the TAXUS Moderate Release stent system is safe and effective in the treatment of long, complex coronary artery lesions provides the evidence base for the more widespread use of drug-eluting stents in contemporary clinical practice.

Adult↗