PubMed Health⌕ Search

Biomedical subjects

Eduard E de Lange

Publications and source records attributed to Eduard E de Lange.

At least 19 recordsLinked to original sources

Evaluation of emphysema severity and progression in a rabbit model: comparison of hyperpolarized 3He and 129Xe diffusion MRI with lung morphometry.

The apparent diffusion coefficients (ADCs) of hyperpolarized (3)He and (129)Xe gases were measured in the lungs of rabbits with elastase-induced emphysema and correlated against the mean chord length from lung histology. In vivo measurements were performed at baseline and 2, 4, 6, and 8 wk after instillation of elastase (mild and moderate emphysema groups) or saline (control group). ADCs were determined from acquisitions that used two b values. To investigate the effect of b value on the results, b-value pairs of 0 and 1.6 s/cm(2) and 0 and 4.0 s/cm(2) were used for (3)He, and b-value pairs of 0 and 5.0 s/cm(2) and 0 and 10.0 s/cm(2) were used for (129)Xe. At 8 wk after instillation, the rabbits were euthanized, and the lungs were analyzed histologically and morphometrically. ADCs for the rabbits in the control group did not change significantly from baseline to week 8, whereas ADCs for the rabbits in the emphysema groups increased significantly (P < 0.05) for all gas and b-value combinations except (129)Xe with the b-value pair of 0 and 5.0 s/cm(2). The largest percent change in mean ADC from baseline to week 8 (15.3%) occurred with (3)He and the b-value pair of 0 and 1.6 s/cm(2) for rabbits in the moderate emphysema group. ADCs (all b values) were strongly correlated (r = 0.62-0.80, P < 0.001) with mean chord lengths from histology. These results further support the ability of diffusion-weighted MRI with hyperpolarized gases to detect regional and global structural changes of emphysema within the lung.

Animals↗

Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging.

PURPOSE: To determine whether hyperpolarized helium-3 (HHe) diffusion MR can detect the expected enlargement of alveoli that occurs with lung growth during childhood. MATERIALS AND METHODS: A total of 29 normal subjects aged four to 30 years underwent HHe diffusion MR imaging with the b-value pair 0, 1.6 second/cm(2). A second acquisition during a separate breathhold was performed using the b-value pair 0, 4 second/cm(2) to evaluate the dependence on b-value. The mean apparent diffusion coefficient (ADC) and lung volume for each acquisition and each subject was determined. RESULTS: Subjects as young as four years of age were able to cooperate with the imaging procedure. The mean ADC increased with increasing subject age (r = 0.8; P < 0.001), with a 55% increase in mean ADC from the youngest to oldest subject. Lung volumes measured on MR were highly repeatable for the two HHe MR acquisitions (r = 0.980, P < 0.001). The mean ADC values measured with the two different b-value pairs were highly correlated (r = 0.975; P < 0.001), but the higher b-value pair resulted in slightly lower mean ADCs (P < 0.001). CONCLUSION: HHe diffusion MR appears to detect the expected increase in alveolar size during childhood, and thus HHe MR may be a noninvasive method to assess development of the lung microstructure.

Adolescent↗

Time dependence of 3He diffusion in the human lung: measurement in the long-time regime using stimulated echoes.

A stimulated-echo-based technique was developed to measure the long-time-scale apparent diffusion coefficient (ADC) of hyperpolarized 3He during a single breath-hold acquisition. Computer simulations were used to evaluate the performance of the technique and guide the selection of appropriate parameter values for obtaining accurate ADC values. The technique was used in 10 healthy subjects and two subjects with chronic obstructive pulmonary disease (COPD) to measure the global ADC for diffusion times between a few tenths of a second and several seconds, and to acquire spatial maps of the ADC for a diffusion time of 1.5 s. The reproducibility of the technique and its sensitivity to the direction of diffusion sensitization were also investigated. In healthy subjects, global ADC values decreased by severalfold over the range of diffusion times measured (mean values = 0.039 and 0.023 cm2/s at diffusion times of 0.61 and 1.54 s, respectively). ADC maps were generally uniform, with mean values similar to the corresponding global values. For the two COPD subjects, global ADC values were substantially greater than those of every healthy subject at all diffusion times measured. In addition, regional elevations of ADC values were far more conspicuous on long-time-scale ADC maps than on short-time-scale ADC maps.

Adult↗

Science to practice: what is new about detecting emphysema?

Through the use of diffusion-weighted 3He MR imaging, Fain et al in this issue of Radiology demonstrated the potential for detection of early emphysema in the lungs of healthy smokers. The technique possibly could become an important tool for understanding the pulmonary processes that occur with emphysema, for implementing treatment before clinical symptoms occur, and for monitoring the effect of treatment.

Diffusion Magnetic Resonance Imaging↗

Evaluation of asthma with hyperpolarized helium-3 MRI: correlation with clinical severity and spirometry.

BACKGROUND: Accurate characterization of asthma severity is difficult due to the variability of symptoms. Hyperpolarized helium-3 MRI (H(3)HeMR) is a new technique in which the airspaces are visualized, depicting regions with airflow obstruction as "ventilation defects." The objective of this study was to compare the extent of H(3)HeMR ventilation defects with measures of asthma severity and spirometry. METHODS: Patients with a physician diagnosis of asthma and normal control subjects underwent H(3)HeMR. For each person, the number and size of ventilation defects were scored and the average number of ventilation defects per slice (VDS) was calculated. The correlations of the imaging findings with measures of asthma severity and spirometry were determined. RESULTS: There were 58 patients with asthma (mild-intermittent, n = 13; mild-persistent, n = 13; moderate-persistent, n = 20; and severe-persistent, n = 12) and 18 control subjects. Mean +/- SE VDS for asthmatics was significantly greater than for control subjects (0.99 +/- 0.15 vs 0.26 +/- 0.22, p = 0.004). Among asthmatics, VDS was significantly higher for the group with moderate-persistent and severe-persistent disease than for the group with mild-intermittent and mild-persistent disease (1.37 +/- 0.24 vs 0.53 +/- 0.12, p < 0.001). VDS correlated significantly with FEV(1)/FVC (r = - 0.51, p = 0.002), forced expiratory flow between 25% and 75% from the beginning of FVC (FEF(25-75%)) percentage of predicted for height, sex, and race (%predicted) [r = - 0.50, p = 0.001], and FEV(1) %predicted (r = - 0.40, p = 0.002), but not with FVC %predicted (r = - 0.26, p = 0.057) and peak expiratory flow %predicted (r = - 0.16, p = 0.231). Many asthmatics had an elevated VDS, but their spirometric indexes, except FEF(25%-75%), were normal. Most ventilation defects were < 3 cm in size for all asthmatics. In the group of patients with moderate-to-severe persistent asthma, there were more defects > or =3 cm than in the group with mild-intermittent and mild-persistent disease (p = 0.021). CONCLUSIONS: Regional changes of airflow obstruction in asthmatics depicted by H(3)HeMR correlate with measures of asthma severity and spirometry.

Adolescent↗

Hyperpolarized 3He lung imaging at 0.5 and 1.5 Tesla: a study of susceptibility-induced effects.

Hyperpolarized (3)He MRI of the human lung was performed at 0.54 and 1.5 T using identical software and hardware (except for RF coils) at both field strengths. The T(*) (2) of (3)He gas in the lung was measured, and the effects of magnetic-susceptibility-induced field inhomogeneities on the appearance of interleaved-spiral and interleaved-echo-planar lung images at 1.5 T were compared to those at 0.54 T. Mean T(*) (2) values for (3)He gas in the healthy human lung were 26.8 +/- 1.5 ms and 67.9 +/- 1.3 ms at 1.5 and 0.54 T, respectively. At 0.54 T, interleaved-spiral images showed markedly less blurring due to susceptibility effects compared to images acquired at 1.5 T. At both 0.54 and 1.5 T, interleaved-echo-planar images appeared essentially identical to corresponding GRE images, even though the data-sampling period per echo and echo time were substantially longer for the interleaved-echo-planar images acquired at 0.54 T.

Echo-Planar Imaging↗

Hyperpolarized HHe 3 MRI of the lung in cystic fibrosis: assessment at baseline and after bronchodilator and airway clearance treatment.

RATIONALE AND OBJECTIVES: The purpose of this study is to determine hyperpolarized helium 3 (HHe) magnetic resonance (MR) findings of the lung in patients with cystic fibrosis (CF) compared with healthy subjects and determine whether HHe MR can detect changes after bronchodilator therapy or mechanical airway mucus clearance treatment. MATERIALS AND METHODS: Thirty-one subjects, 16 healthy volunteers and 15 patients with CF, underwent HHe lung ventilation MR imaging and spirometry at baseline. Eight patients with CF then were treated with nebulized albuterol, after which a follow-up HHe MR scan was obtained. Subsequently, recombinant human deoxyribonuclease (DNase) treatment and chest physical therapy were performed in these eight subjects, followed by a third HHe MR scan. For each MR study, the number of ventilation defects was scored by a human reader. RESULTS: Patients with CF had significantly more HHe MR ventilation defects per image than healthy subjects (mean, 8.2 defects in patients with CF vs 1.6 defects in healthy subjects; P < .05). Even the four subjects with CF with a normal forced expiratory volume in 1 second had significantly more ventilation defects than healthy subjects (mean, 6.5 defects in these patients with CF; P = .0002). After treatment with albuterol, there was a small, but statistically significant, decrease in number of ventilation defects (mean, 9.6-8.0 defects; P = .025). After DNase and chest physical therapy, there was a trend toward increasing ventilation defects (mean, 8.3 defects; P = .096), but with a residual net improvement relative to baseline. CONCLUSION: In patients with CF, HHe MR ventilation defects correlate with spirometry, change with treatment, and are elevated in number in patients with CF with normal spirometry results. Thus, HHe MR appears to possess many of the characteristics required of a biomarker for pulmonary CF and may be useful in the evaluation of CF pulmonary disease severity or progression.

Administration, Inhalation↗

Functional MRI of the lung using hyperpolarized 3-helium gas.

Lung imaging has traditionally relied on x-ray methods, since proton MRI is limited to some extent by low proton density in the lung parenchyma and static field inhomogeneities in the chest. The relatively recent introduction of MRI of hyperpolarized noble gases has led to a rapidly evolving field of pulmonary MRI, revealing functional information of the lungs, which were hitherto unattainable. This review article briefly describes the physical background of the technology, and subsequently focuses on its clinical applications. Four different techniques that have been used in various human investigations are discussed: ventilation distribution, ventilation dynamics, and small airway evaluation using diffusion imaging and oxygen uptake assessment.

Administration, Inhalation↗

Rapid hyperpolarized 3He diffusion MRI of healthy and emphysematous human lungs using an optimized interleaved-spiral pulse sequence.

PURPOSE: To develop and validate an interleaved-spiral diffusion pulse sequence capable of hyperpolarized (3)He MR imaging of the whole lung in less than 10 seconds. MATERIALS AND METHODS: Hyperpolarized (3)He diffusion measurements were performed in seven healthy volunteers and five patients with emphysema using an interleaved-spiral pulse sequence that provided 11 contiguous 15-mm thick coronal ADC maps, with an in-plane resolution of 3.9 mm, covering the whole lung in 5.5 seconds. The resulting means and SDs of ADC values were compared statistically to those from a gradient-echo pulse sequence with identical resolution and diffusion-weighting gradients that acquired five ADC maps in 10.5 seconds. RESULTS: High-quality diffusion-weighted interleaved-spiral images covering the whole lung were obtained, and showed no significant susceptibility-induced image degradation compared to corresponding gradient-echo images. On a subject-by-subject basis, the means and SDs of ADC values for the interleaved-spiral technique were not statistically different from those for the gradient-echo technique. The mean ADC values from the two techniques were highly correlated on a section-by-section basis (R = 0.99). CONCLUSION: The interleaved-spiral diffusion pulse sequence permits rapid acquisition of contiguous ADC maps covering the whole lung during a short breath-hold period, and provides ADC values that are statistically equivalent to those from standard gradient-echo techniques.

Adult↗

Imaging the lungs in asthmatic patients by using hyperpolarized helium-3 magnetic resonance: assessment of response to methacholine and exercise challenge.

BACKGROUND: Imaging of gas distribution in the lungs of patients with asthma has been restricted because of the lack of a suitable gaseous contrast agent. Hyperpolarized helium-3 (HHe3) provides a new technique for magnetic resonance imaging of lung diseases. OBJECTIVE: We sought to investigate the use of HHe3 gas to image the lungs of patients with moderate or severe asthma and to assess changes in gas distribution after methacholine and exercise challenge. METHODS: Magnetic resonance imaging was performed in asthmatic patients immediately after inhalation of HHe3 gas. In addition, images were obtained before and after methacholine challenge and a standard exercise test. RESULTS: Areas of the lung with no signal or sharply reduced HHe3 signal (ventilation defects) are common in patients with asthma, and the number of defects was inversely related to the percent predicted FEV(1) (r = 0.71, P <.002). After methacholine challenge (n = 3), the number of defects increased. Similarly, imaging of the lungs after exercise (n = 6) showed increased ventilation defects in parallel with decreases in FEV(1). The increase in defects after challenge in these 9 asthmatic patients was significant both for the number (P <.02) and extent (P <.02) of the defects. The variability and speed of changes in ventilation and the complete lack of signal in many areas is in keeping with a model in which the defects result from airway closure. CONCLUSION: HHe3 magnetic resonance provides a new technique for imaging the distribution of inhaled air in the lungs. The technique is suitable for following responses to treatment of asthma and changes after methacholine or exercise challenge.

Adolescent↗

Applications of hyperpolarized helium-3 gas magnetic resonance imaging in pediatric lung disease.

Hyperpolarized gas magnetic resonance imaging (MRI) of the lung provides high temporal and spatial resolution images of the air spaces of the lung and can be used to elucidate both lung ventilation and morphology. Because no ionizing radiation is involved, hyperpolarized gas MRI is ideal for the evaluation of pediatric lung diseases. In the article, we describe briefly the basic principles of hyperpolarized gas MRI, review the literature of hyperpolarized gas MRI in two pediatric lung diseases (asthma and cystic fibrosis), and discuss possible future clinical applications of hyperpolarized gas imaging in pediatric lung disease.

Asthma↗

Merging parametric active contours within homogeneous image regions for MRI-based lung segmentation.

Inhaled hyperpolarized helium-3 (3He) gas is a new magnetic resonance (MR) contrast agent that is being used to study lung functionality. To evaluate the total lung ventilation from the hyperpolarized 3He MR images, it is necessary to segment the lung cavities. This is difficult to accomplish using only the hyperpolarized 3He MR images, so traditional proton (1H) MR images are frequently obtained concurrent with the hyperpolarized 3He MR examination. Segmentation of the lung cavities from traditional proton (1H) MRI is a necessary first step in the analysis of hyperpolarized 3He MR images. In this paper, we develop an active contour model that provides a smooth boundary and accurately captures the high curvature features of the lung cavities from the 1H MR images. This segmentation method is the first parametric active contour model that facilitates straightforward merging of multiple contours. The proposed method of merging computes an external force field that is based on the solution of partial differential equations with boundary condition defined by the initial positions of the evolving contours. A theoretical connection with fluid flow in porous media and the proposed force field is established. Then by using the properties of fluid flow we prove that the proposed method indeed achieves merging and the contours stop at the object boundary as well. Experimental results involving merging in synthetic images are provided. The segmentation technique has been employed in lung 1H MR imaging for segmenting the total lung air space. This technology plays a key role in computing the functional air space from MR images that use hyperpolarized 3He gas as a contrast agent.

Administration, Inhalation↗

Hepatic MR imaging with ferumoxides: multicenter study of safety and effectiveness of direct injection protocol.

PURPOSE: To compare the safety and effectiveness of an undiluted direct injection of ferumoxides with those of a diluted slow infusion of ferumoxides during 30 minutes in patients with known liver lesions or in those suspected of having them. MATERIALS AND METHODS: Two hundred thirty-three patients at 16 institutions were randomized to receive either an undiluted direct injection of 0.56 mg of iron per kilogram of body weight of ferumoxides administered during 2 minutes (2 mL/min) or a diluted slow infusion administered during 30 minutes. Safety was assessed with monitoring for adverse events and laboratory tests. For sensitivity, specificity, and accuracy analysis, two independent blinded observers identified and classified lesions as benign or malignant with precontrast images and with pre- and postcontrast images combined. RESULTS: There was no statistically significant difference in adverse events in the group with direct injection compared with those in the group with infusion (21 [18%] of 114 patients vs 19 [17%] of 112 patients, respectively). No serious adverse events were observed. The most common adverse events in the group with direct injection versus the group with infusion were headache (five [4%] of 114 vs three [3%] of 112, respectively) and back pain (five [4%] of 114 vs three [3%] of 112, respectively). Overall, in 68 (62%) of 109 patients with direct injection and 71 (66%) of 108 patients with infusion, additional magnetic resonance (MR) imaging information was obtained after ferumoxides administration (P =.67). Sensitivity, specificity, and accuracy for the diagnosis of malignancy were significantly improved by adding images obtained after ferumoxides administration to the images obtained before contrast agent administration (P <.05 for all comparisons). CONCLUSION: Direct injection of ferumoxides has safety and effectiveness profiles similar to those of slow infusion of the agent. Further findings indicate that the addition of ferumoxides increases the sensitivity and specificity of hepatic MR evaluation when compared with unenhanced MR imaging.

Adult↗

MRI of the lungs using hyperpolarized noble gases.

The nuclear spin polarization of the noble gas isotopes (3)He and (129)Xe can be increased using optical pumping methods by four to five orders of magnitude. This extraordinary gain in polarization translates directly into a gain in signal strength for MRI. The new technology of hyperpolarized (HP) gas MRI holds enormous potential for enhancing sensitivity and contrast in pulmonary imaging. This review outlines the physics underlying the optical pumping process, imaging strategies coping with the nonequilibrium polarization, and effects of the alveolar microstructure on relaxation and diffusion of the noble gases. It presents recent progress in HP gas MRI and applications ranging from MR microscopy of airspaces to imaging pulmonary function in patients and suggests potential directions for future developments.

Animals↗

MR angiography of the mesenteric vasculature.

MRA has evolved from a research tool to a robust clinical diagnostic modality. In many centers worldwide, it is the technique of choice for evaluating patients with suspected CMI, assessing operability of patients with pancreatic cancer, and investigating the portal system. Evolving indications include the assessment of liver transplant patients before and after transplant and of living related liver transplant donors. The search for the bleeding source in patients with gastrointestinal hemorrhage may be an indication in the future, once intravascular contrast agents become available.

Contrast Media↗

Overuse and sports-related injuries of the ankle and hind foot: MR imaging findings.

Professional and recreational sporting activities have increased substantially in recent years and have led to a rise in the number of sports-related and overuse injuries. Magnetic resonance (MR) imaging has become an important tool for evaluating the lower leg for providing the necessary information for patient management and rehabilitation following this injury. The purpose of this essay is to give an overview of the MR findings of common overuse injuries and sports-related injuries to the bones and soft-tissue structures of the hind foot and ankle.

Ankle Injuries↗

Bone marrow ill-defined hyperintensities with tarsal coalition: MR imaging findings.

INTRODUCTION: To report the occurrence and pattern of ill-defined subchondral hyperintensities on Magnetic Resonance (MR) imaging in patients with talocalcaneal coalition (TCC). METHODS AND MATERIAL: MR imaging of both feet was performed in 10 consecutive patients with 14 TCCs. There were eight males and two females with ages ranging from 9-52 years (mean 25 years). Twelve of the 14 TCCs were symptomatic. MR imaging sequences included T1- and T2-weighted as well as STIR images. The images were evaluated for the presence, extent and location of ill-defined subchondral hyperintensities on MR images in the hindfoot. RESULTS: Ill-defined subchondral hyperintensities on MR imaging were present in 12 (86%) of the 14 hindfeet with TCCs. Two of these were without symptoms. No abnormalities were seen in two symptomatic hindfeet. DISCUSSION AND CONCLUSION: In our series hyperintensities located in the subchondral bone adjacent to the coalition was relatively common in TCC. The presence of this specific pattern in the subchondral bone adjacent to the coalition may be indicative of tarsal coalition.

Adult↗

Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes--initial experience.

PURPOSE: To quantitatively evaluate hyperpolarized helium 3 ((3)He) diffusion magnetic resonance (MR) images of the lung in patients with emphysema and to determine whether apparent diffusion coefficients (ADCs) measured with MR imaging correlate with spirometric indexes. MATERIALS AND METHODS: Hyperpolarized (3)He diffusion MR imaging was performed in 16 healthy volunteers and 11 patients. Coronal diffusion-sensitized MR images were obtained during suspended respiration after inhalation of laser-polarized (3)He gas, and images of the ADC were calculated. Spirometry was performed immediately before imaging. The mean and SD of the ADCs were compared between subject groups and were correlated with spirometric indexes. RESULTS: ADC images were homogeneous in volunteers, but demonstrated regional variations in patients. The mean and SD of the ADCs for patients were significantly larger (P <.002) than those for volunteers. The mean ADCs for all subjects correlated with the percentage of predicted forced expiratory volume in 1 second, or FEV(1), (r = -0.797, P <.001) and the ratio of FEV(1) to forced vital capacity, or FVC, (r = -0.930, P <.001). ADC images in patients demonstrated a significant increase (P <.001) in the ADCs in the upper regions compared with the lower regions of the lung. CONCLUSION: Hyperpolarized (3)He diffusion MR imaging demonstrated potential for use in evaluating the global and regional severity of emphysema.

Adult↗