Ablation of left ventricular epicardial outflow tract tachycardia from the distal great cardiac vein.

OBJECTIVES: The purpose of this study was to examine the feasibility and safety of ablation of idiopathic outflow tract ventricular tachycardia (OTVT) from the distal ramifications of the coronary sinus (CS). BACKGROUND: A significant minority of patients presenting with idiopathic OTVT have an epicardial focus, the standard approach to which involves ablation from within one of the aortic valve cusps (AVCs). We describe the successful ablation of idiopathic epicardial OTVT from within the CS in the distal great cardiac vein (GCV). METHODS: Ablation from the distal GCV was performed in 5 patients with idiopathic OTVT who had unfavorable mapping, in some cases unsuccessful ablation from various endocardial and epicardial sites including the AVCs, and in 1 patient via the direct epicardial approach. An electroanatomic mapping system (Carto) was used in 3 patients, and conventional mapping was performed in 2 patients, and in 3 patients cryothermal ablation was performed. RESULTS: In all patients, the first ablation lesion in the GCV successfully eliminated the arrhythmia. All patients have remained free of VT after a mean follow-up of 24 (7 to 44) months. There were no immediate or long-term complications. CONCLUSIONS: Idiopathic epicardial OTVT can be successfully ablated from the distal GCV, and should be seen as an alternative to ablation from the aortic valve cusps.

Adult↗

Implantation of bilateral carotid artery filters to allow safe removal of left atrial thrombus during ablation of atrial fibrillation.

Left atrial clot formation is a feared complication of catheter ablation for atrial fibrillation. We report a case of left atrial thrombus that formed around the circular mapping catheter before the delivery of RF. Successful retrieval of the clot was obtained by withdrawing the catheters while protecting the anterior cerebral circulation by positioning temporary carotid artery filters.

Atrial Fibrillation↗

Embolic events and char formation during pulmonary vein isolation in patients with atrial fibrillation: impact of different anticoagulation regimens and importance of intracardiac echo imaging.

UNLABELLED: Thromboembolic events are important complications of pulmonary vein isolation (PVI) procedures, occurring in up to 2.8% of patients. In this study, we report the incidence of char formation and embolic events with different anticoagulation protocols prospectively changed to reduce such complication. METHODS: A total of 785 patients (mean age: 54 years, 83.5% male) underwent catheter-based PVI for treatment of drug refractory, symptomatic atrial fibrillation (AF). PVI was performed utilizing different strategies including radiofrequency (RF) using temperature control energy delivery and RF using intracardiac echocardiography (ICE)-guided power titration. Patients were divided based on the anticoagulation protocol into three groups: in group 1 (194 patients), activation coagulation time (ACT) was maintained between 250 and 300 seconds; in group 2 (180 patients), ACT was maintained between 300 and 350 seconds plus the IV infusion of eptifibatide (135 microg/kg bolus + 0.5 microg/kg/min); and in group 3 (411 patients), ACT was maintained between 350 and 400 seconds. RESULTS: Char formation was detected in 69 patients of group 1, 5 of group 2, and 8 of group 3. An embolic event was observed in 7 patients of group 1, 3 of group 2, and 2 of group 3 (P = 0.01; group 1 vs group 3). Higher degree of anticoagulation with heparin was associated with a reduced incidence of embolic events even after removing the patients undergoing ICE-guided ablation (P = 0.04). CONCLUSION: More aggressive anticoagulation with heparin reduced periprocedural embolic events. The use of platelet inhibition does not have incremental beneficial effect. None of the anticoagulation protocol abolished char formation.

Anticoagulants↗

Impact of age on the outcome of pulmonary vein isolation for atrial fibrillation using circular mapping technique and cooled-tip ablation catheter:.

INTRODUCTION: A retrospective analysis was performed to define the impact of age on the outcomes and complications in patients undergoing pulmonary vein isolation (PVI). PVI is an evolving technique for the management of atrial fibrillation (AF). The impact of age on the risks, outcomes, and complications of PVI has not been well defined. METHODS AND RESULTS: A total of 323 patients (259 men and 64 women; age 18-79 years) underwent PVI for treatment of drug-refractory symptomatic AF. An ostial isolation of the pulmonary veins was done using a cooled-tip ablation catheter guided by circular mapping. The patients were divided into three groups based on age (group I: <50 years, group II: 51-60 years, group III: >60 years) and the results were compared. There were 106 patients in group I, 114 patients in group II, and 103 patients in group III (mean age 41.3 +/- 7.8 years, 55.4 +/- 2.75 years, and 66.6 +/- 4.18 years, respectively) who underwent PVI for paroxysmal (53.8%), persistent (10.8%), or permanent (35.3%) AF. Baseline characteristics were similar except for a higher prevalence of hypertension and/or structural heart disease in groups II and III (58% and 63% vs 33% in group I, respectively). The procedural variables were similar in all age groups. The overall risk of complications was similar in the three groups, except that the risk of stroke was significantly higher in patients >60 years of age (3% vs 0%; P < 0.05). The recurrence rates of AF were similar in the three age groups (15.1%, 16.7%, and 18.4%, respectively; P > 0.05). The risk of severe pulmonary vein stenosis (1.8%, 2.6%, and 0.9%, respectively) was low and did not vary with age. CONCLUSION: PVI is a safe and effective treatment for patients with drug-refractory symptomatic AF, and its benefits extend to all age groups. The risk of procedural complications, especially thromboembolic events, appears to be higher in the elderly age group. This observation needs to be considered while assessing potential candidates for the procedure.

Adolescent↗

Impact of coronary sinus lead position on biventricular pacing: mortality and echocardiographic evaluation during long-term follow-up.

INTRODUCTION: Biventricular pacing is an established treatment for congestive heart failure. Whether the anatomic location of the coronary sinus (CS) lead affects outcomes is unknown. The aim of this study was to evaluate the clinical response and mortality in patients who had transvenous CS leads placed in different anatomic branches for biventricular pacing. METHODS AND RESULTS: We evaluated 233 consecutive patients with New York Heart Association (NYHA) class III-IV heart failure and ejection fraction <35% who had successful placement of a transvenous left ventricular lead through a CS venous branch. Patients were divided into two groups based on anatomic lead position. Group 1 (n = 66) included leads in the anterior and anterolateral branches. Group 2 (n = 167) included leads in the lateral and posterolateral branches. Postimplant, functional capacity improved from an average 3.1 to 2.7 in group 1 (P = 0.001) and from 3.1 to 2.3 in group 2 (P = 0.001). Left ventricular ejection fraction (LVEF) measured by transthoracic echocardiography did not improve significantly in group 1 (pre-LVEF 18%, post-LVEF 20%; P = NS) but increased significantly from 19% to 27% in group 2 (P = 0.008). Despite the difference in ejection fraction response, the mortality in the two groups after a mean follow-up of 546 days was similar (13.6% group 1 vs 17.9% group 2). CONCLUSION: Placement of the CS lead in the lateral and posterolateral branches is associated with significant improvement in functional capacity and greater improvement in left ventricular function compared with the anterior CS location. This improvement does not appear to influence mortality.

Aged↗

Pulmonary vein stenosis after radiofrequency ablation of atrial fibrillation: functional characterization, evolution, and influence of the ablation strategy.

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of ablation for atrial fibrillation. The impact of different ablation strategies on the incidence of PV stenosis and its functional characterization has not been described. METHODS AND RESULTS: PV isolation was performed in 608 patients. An electroanatomic approach was used in 71 and circular mapping in 537 (distal isolation, 25; ostial isolation based on PV angiography, 102; guided by intracardiac echocardiography, 140; with energy delivery based on visualization of microbubbles, 270). Severe (> or =70%) narrowing was detected in 21 patients (3.4%), and moderate (50% to 69%) and mild (<50%) narrowing occurred in 27 (4.4%) and 47 (7.7%), respectively. Severe stenosis occurred in 15.5%, 20%, 2.9%, 1.4%, and 0%, respectively. Development of symptoms was correlated with involvement of >1 PV with severe narrowing (P=0.01), whereas all patients with mild and moderate narrowing were asymptomatic. In the latter group, lung perfusion (V/Q) scans were normal in all but 4 patients. All patients with severe stenosis had abnormal perfusion scans. CONCLUSIONS: V/Q scans are useful to assess the functional significance of PV stenosis. Mild and moderate degrees of PV narrowing are not associated with development of symptoms and seem to have no or minimal detrimental effect on pulmonary flow. The incidence of severe PV stenosis seems to be declining with better imaging techniques to ensure ostial isolation and to guide power titration. Mild narrowing 3 months after ablation does not preclude future development of severe stenosis and should be assessed with repeat imaging studies.

Atrial Fibrillation↗

Transcatheter angioplasty for acquired pulmonary vein stenosis after radiofrequency ablation.

BACKGROUND: Pulmonary vein stenosis has recently been recognized as a complication of radiofrequency ablation for atrial fibrillation. This study evaluates the presentation of affected patients and the role of transcatheter therapy for this patient population. METHODS AND RESULTS: This study used a retrospective review of data from 19 patients (age, 51+/-13 years) with pulmonary vein stenosis who underwent catheterization and angiography between December 2000 and December 2002. Quantitative perfusion and spiral CT scans were performed for initial diagnosis and follow-up. The median duration between radiofrequency ablation and the reported onset of respiratory symptoms for 18 of 19 patients was 7.5 weeks (0.1 to 48). After the onset of symptoms, all but two patients were initially misdiagnosed with a symptoms-to-diagnosis duration of 16 weeks (2-59). At initial catheterization, 17 of 19 patients had angioplasty in 30 veins with stent placement in 5 vessels when a flap occurred. Overall vessel diameter increased from 2.6+/-1.6 to 6.6+/-2.4 mm (P<0.0001). There were 4 procedure-related adverse events but no long-term sequelae. Immediate follow-up showed improved flow to involved lung segments. At a median follow-up of 43 weeks (2-92), although repeat angioplasty for restenosis was necessary in 8 of 17 patients, 15 of 17 patients currently have no or minimal persistent symptoms. CONCLUSIONS: Pulmonary vein stenosis after radiofrequency ablation for atrial fibrillation is often misdiagnosed. Although further follow-up is necessary to determine long-term success, our data indicate better pulmonary vein flow and symptomatic improvement in the majority of patients undergoing dilation of postablation pulmonary vein stenosis.

Angioplasty, Balloon↗

Pulmonary vein stenosis after catheter ablation of atrial fibrillation: emergence of a new clinical syndrome.

BACKGROUND: Pulmonary vein isolation is a new, effective curative procedure for selected patients with atrial fibrillation. Pulmonary vein stenosis is a potential complication and may lead to symptoms that are often underrecognized. OBJECTIVE: To describe the clinical course and symptoms associated with pulmonary vein stenosis developing after ablation in the pulmonary veins. DESIGN: Retrospective study. SETTING: Tertiary care referral center. PATIENTS: 335 patients referred for catheter ablation of drug-refractory atrial fibrillation. INTERVENTION: Pulmonary vein electrical isolation using radiofrequency catheter ablation. MEASUREMENTS: Three months after ablation, patients underwent routine screening for pulmonary vein stenosis with spiral computed tomography. Screening was considered earlier if symptoms suggestive of stenosis developed and was repeated at 6 and 12 months if any pulmonary vein narrowing was observed. Pulmonary vein angiography and dilatation were offered to patients with severe (>70%) stenosis. RESULTS: Severe pulmonary vein stenosis was detected in 18 patients (5% [95% CI, 3.2% to 8.4%]) a mean (+/-SD) of 5.2 +/- 2.6 months after ablation. Eight of these 18 patients (44%) were asymptomatic, but 8 (44%) reported shortness of breath, 7 (39%) reported cough, and 5 (28%) reported hemoptysis. Radiologic abnormalities were present in 9 patients (50%) and led to diagnoses of pneumonia (4 patients), lung cancer (1 patient), and pulmonary embolism (2 patients). Pulmonary vein stenosis was not considered in any patient during the initial work-up. Dilatation of the affected vein was performed in 12 patients. Postintervention lung perfusion scans revealed significant improvement in lung flow. CONCLUSIONS: Severe pulmonary vein stenosis after catheter ablation of atrial fibrillation is associated with respiratory symptoms that frequently mimic more common diseases, often leading to erroneous diagnostic and therapeutic procedures. Awareness of this syndrome is important for proper and prompt management.

Adolescent↗

Nonthoracotomy implantable defibrillator lead extraction: results and comparison with extraction of pacemaker leads.

Extraction of pacemaker leads has been demonstrated to be successful and safe in experienced hands using current tools. Whether application of such techniques and tools yield similar results among patients undergoing extraction of nonthoracotomy implantable defibrillator leads is unknown. This report describes a retrospective analysis of indications, techniques used, and outcome of patients who had a single ventricular nonthoracotomy implantable defibrillator lead extracted at The Cleveland Clinic Foundation. Results were compared to a matched population of patients undergoing extraction of ventricular pacemaker leads from a national registry and to the experience with pacemaker lead extraction at The Cleveland Clinic Foundation. Successful complete extraction of ventricular nonthoracotomy implantable defibrillator leads, in the absence of major complications, was achieved in 96.9% of attempts to extract leads from 161 patients. Clinical success was achieved in 98.1% of patients. Failure occurred in three patients. Two patients had major complications, including one death. The most common indication for extraction was infection (46.6%), followed by lead failure (34.2%). Procedure (140.8 vs 171.2 minutes, P<0.01) and fluoroscopy (9.9 vs 11.0 minutes, P<0.01) times compared favorably with those obtained from the pacemaker lead extraction database. Use of LASER did not influence the safety of the procedure or fluoroscopy times. Extraction of ventricular nonthoracotomy implantable defibrillator leads using currently available tools is a complex but effective procedure. In experienced hands, excellent success rates should be achieved with a low incidence of complications.

Adolescent↗

Evidence of specialized conduction cells in human pulmonary veins of patients with atrial fibrillation.

UNLABELLED: Specialized Conducting Cells in Human PV. INTRODUCTION: Depolarizations similar to those from the sinus node have been documented from the pulmonary veins after isolation procedures. We assessed the hypothesis that sinus node-like tissue is present in the pulmonary veins of humans. METHODS AND RESULTS: Pulmonary vein tissue was obtained from five autopsies (four individuals with a history of atrial fibrillation and one without a history of atrial arrhythmias) and five transplant heart donors. Autopsy veins were fixed in formaldehyde and processed for light microscopy to identify areas having possible conductive-like tissue. Areas requiring additional study were extracted from paraffin blocks and reprocessed for electron microscopy. Donor specimens were fixed in formaldehyde for histologic sections and glutaraldehyde for electron microscopy. Myocardial cells with pale cytoplasm were identified by light microscopy in 4 of the 5 autopsy subjects. Electron microscopy confirmed the presence of P cells, transitional cells, and Purkinje cells in the pulmonary veins of these cases. CONCLUSION: Our report is the first to show the presence of P cells, transitional cells, and Purkinje cells in human pulmonary veins. Whether these cells are relevant in the genesis of atrial fibrillation requires further study.

Adolescent↗

Pacing in heart failure: the benefit of resynchronization.

Cardiac resynchronization therapy involves pacing of the left ventricle alone or in concert with the right ventricle within a certain range of atrioventricular delay. It may help patients with systolic heart failure and conduction disturbances by optimizing myocardial performance.

Arrhythmias, Cardiac↗

Ablation of atrial fibrillation.

Associated with significant morbidity and mortality, atrial fibrillation is one of the most common cardiac rhythm disorders. Cure of this arrhythmia has been elusive over the years, despite development of different antiarrhythmic drugs and advances in the understanding of its pathophysiology. Initial experience with catheter ablation procedures based on the creation of linear lesions in both atria has been disappointing, but has led to the key observation that focal triggers localized in the pulmonary veins are responsible for initiation of atrial fibrillation, and thus are suitable targets for catheter ablation. With advances in technology and larger experience, it has become clear that electrical isolation of all four pulmonary veins from the left atrium provides the higher cure rates. However, the procedure is still operator dependent and is associated with a small but significant risk of pulmonary vein stenosis. Further simplification of the isolation techniques and refinement in the catheter design will allow more widespread use of this procedure and higher success rate.

Atrial Fibrillation↗

Current status and future expectations for multisite pacing in heart failure.

The number of patients with congestive heart failure (CHF) has achieved astonishing proportions. It is a debilitating and usually lethal condition, aside from being responsible for an enormous proportion of health care expenditures. Advances in medical therapy have not been sufficient to significantly improve prognosis, and heart transplantation can only benefit a minority of patients. Biventricular pacing has emerged as a promising form of therapy for patients with severe, medical refractory CHF with ventricular conduction defects. However, there are many technical issues to be solved, and better methods of selecting patients who respond favorably to this form of therapy are yet to be developed. This article reviews the rationale, delivery modes, and available data supporting multisite cardiac pacing as an alternative form of therapy for the failing heart.

Cardiac Pacing, Artificial↗

Ablation of focal atrial fibrillation.

In the past decades management of atrial fibrillation (AF) has been based mainly on drug therapy. New insights into the pathophysiology of AF initiation and maintenance have provided the background for the design of catheter based procedures. The crucial role of the pulmonary veins (PVs) as triggers of AF paved the way for successful mapping and ablation. Electrical isolation of all PVs using the circular mapping approach has been shown to be an effective procedure, with reported success rates around 70 to 80% in most series. Intracardiac echocardiography is a very helpful adjunctive tool to facilitate correct positioning of the circular catheter at the PV-left atrial junction, as well as to monitor energy delivery and assist transseptal left atrial access. PV stenosis is a potential serious complication, occurring in around 2% of cases. It presents mainly with respiratory symptoms, although it is frequently asymptomatic. Spiral computed tomography is a reliable non-invasive method for imaging the PVs and can be used to screen patients for PV stenosis after radiofrequency ablation. In symptomatic patients, PV dilatation and stenting is the preferred treatment approach. The possibility of curing AF represents a major breakthrough in invasive cardiac electrophysiology. Isolation of all PVs is a very solid endpoint for successful ablation and should be pursued in all patients. It seems to be associated with high success rates over long term follow-up. Future refinements in catheter technology should provide simpler and faster procedures and render catheter ablation of AF more widespread and accepted.

Atrial Fibrillation↗

Simultaneous epicardial and endocardial mapping of a left-sided posteroseptal accessory pathway associated with a large coronary sinus diverticulum: successful ablation by transection of the diverticulum's neck.

Transcutaneous pericardial instrumentation in a patient with a left-sided posteroseptal accessory pathway associated with a large coronary sinus diverticulum was performed after three previous unsuccessful ablations. The earliest ventricular activation site was recorded epicardially using a catheterin the pericardial space, but energy delivery at this site was not possible due to high impedances. Intravascular linear lesions transecting the neck of the large coronary sinus diverticulum using the pericardial catheter as a target allowed successful radiofrequency catheter ablation of the accessory pathway. This case outlines potential problems with ablations in the pericardial space and provides an alternative solution that can spare patients from open surgical procedures.

Catheter Ablation↗

Use of intracardiac echocardiography for prediction of chronic pulmonary vein stenosis after ablation of atrial fibrillation.

INTRODUCTION: Measurements of pulmonary vein (PV) flow with intracardiac echocardiography (ICE) immediately before and after PV isolation may be a useful method for predicting which patients will develop chronic PV stenosis. METHODS AND RESULTS: We assessed preablation and postablation flows in each of the four PVs using a phase-array ICE catheter in 95 patients (mean age 52 +/- 13) undergoing atrial fibrillation ablation. The ostium of each of the PVs was defined using angiography, electrical mapping, and ICE imaging. Ostial electrical isolation of all PVs was achieved using a 4-mm cooled-tip radiofrequency ablation catheter. Change in PV flow, when present, was examined as both an absolute value and as a percentage of the baseline flow. All patients underwent spiral computed tomography (CT) scans of the PVs 3 months after the procedure for detection of stenosis. The average preablation diastolic flows for the left superior, left inferior, right superior, and right inferior veins were 0.56, 0.54, 0.47, and 0.45 m/sec, respectively. These values increased to 0.74, 0.67, 0.58, and 0.59 m/sec postablation (P < 0.001). Of 380 PVs ablated, the CT scans revealed 2 (1%) with severe (>70%) stenosis, 13 (3%) with moderate (51%-70%) stenosis, and 62 (16%) with mild (< or = 50%) stenosis. The r value between flow and stenosis was only 0.09 (P = NS). CONCLUSION: Acute changes in PV flow immediately after ostial PV isolation do not appear to be a strong predictor of chronic PV stenosis.

Adult↗