Dynamic ventilation imaging from four-dimensional computed tomography.

A novel method for dynamic ventilation imaging of the full respiratory cycle from four-dimensional computed tomography (4D CT) acquired without added contrast is presented. Three cases with 4D CT images obtained with respiratory gated acquisition for radiotherapy treatment planning were selected. Each of the 4D CT data sets was acquired during resting tidal breathing. A deformable image registration algorithm mapped each (voxel) corresponding tissue element across the 4D CT data set. From local average CT values, the change in fraction of air per voxel (i.e. local ventilation) was calculated. A 4D ventilation image set was calculated using pairs formed with the maximum expiration image volume, first the exhalation then the inhalation phases representing a complete breath cycle. A preliminary validation using manually determined lung volumes was performed. The calculated total ventilation was compared to the change in contoured lung volumes between the CT pairs (measured volume). A linear regression resulted in a slope of 1.01 and a correlation coefficient of 0.984 for the ventilation images. The spatial distribution of ventilation was found to be case specific and a 30% difference in mass-specific ventilation between the lower and upper lung halves was found. These images may be useful in radiotherapy planning.

Algorithms↗

Quantification of regional ventilation from treatment planning CT.

PURPOSE: We describe a method of quantifying regional ventilation from the radiotherapy treatment planning computed tomography (CT) images, with the goal of developing functional images for treatment planning and optimization. METHODS AND MATERIALS: A series of exhalation breath-hold (eBH-CT) and inhalation breath-hold (iBH-CT) CT images obtained using a feedback-guided breath-hold technique for radiotherapy treatment planning was selected. The eBH-CT was mapped on a voxel-by-voxel basis to the iBH-CT using a deformable image registration algorithm. By using the average CT number over a 3 mm(3) region surrounding each pair of mapped voxels, the change in fraction of air per voxel (i.e., regional ventilation) was calculated. This methodology was applied to a series of 22 patients. The calculated total ventilation was compared to the change in contoured lung volumes between the exhalation and inhalation CTs (measured tidal volume). RESULTS: A significant correlation was found between the calculated and measured tidal volumes for the left (R = 0.982) and right (R = 0.985), and for both lungs combined (R = 0.985). In the resulting images, the regional ventilation was highly variable and corresponded with the spatial distribution of differences in the CT values (Hounsfield units) between the eBH-CT and the iBH-CT images. CONCLUSIONS: A method of quantifying regional ventilation from radiotherapy treatment planning CT data sets was demonstrated. The ventilation images can be used in plan optimization to minimize injury to functioning lung.

Algorithms↗