PubMed Health⌕ Search

Biomedical subjects

Edward D Brandner

Publications and source records attributed to Edward D Brandner.

2 recordsLinked to original sources

Abdominal organ motion measured using 4D CT.

PURPOSE: To measure respiration-induced abdominal organ motion using four-dimensional computed tomography (4D CT) scanning and to examine the organ paths. METHODS AND MATERIALS: During 4D CT scanning, consecutive CT images are acquired of the patient at each couch position. Simultaneously, the patient's respiratory pattern is recorded using an external marker block taped to the patient's abdomen. This pattern is used to retrospectively organize the CT images into multiple three-dimensional images, each representing one breathing phase. These images are analyzed to measure organ motion between each phase. The displacement from end expiration is compared to a displacement limit that represents acceptable dosimetric results (5 mm). RESULTS: The organs measured in 13 patients were the liver, spleen, and left and right kidneys. Their average superior to inferior absolute displacements were 1.3 cm for the liver, 1.3 cm for the spleen, 1.1 cm for the left kidney, and 1.3 cm for the right kidney. Although the organ paths varied among patients, 5 mm of superior to inferior displacement from end expiration resulted in less than 5 mm of displacement in the other directions for 41 of 43 organs measured. CONCLUSIONS: Four-dimensional CT scanning can accurately measure abdominal organ motion throughout respiration. This information may result in greater organ sparing and planning target volume coverage.

Abdomen↗

Localizing moving targets and organs using motion-managed CTs.

Respiration-induced target and organ motion impacts the radiotherapy strategies of some cancers. Various methods and techniques have been used to investigate motion-related radiotherapy issues, including retrospective 4-dimensional (4D) computed tomography (CT), prospective gated CT, and breath-hold CT scans. This paper reviews these methods and, particularly, the method using retrospective 4D CT scans, which has been developed at our institution. Some motion studies based on retrospective 4D CT images of patients are also examined. These studies have led to reduced planning target volume (PTV) margins for a number of patients, because the respiratory motion was observed to be minimal or gated radiotherapy was used. Respiratory motion managed CTs and, particularly, retrospective 4D CTs are proving to be useful for measuring soft tissue motion, identifying patients who could benefit from gated radiotherapy, and evaluating the effects of respiratory motion during radiotherapy.

Humans↗