Publications and source records attributed to Edward G Walsh.

6 recordsLinked to original sources

Rapid mapping of flow velocity using a new PARSE method.

A new method for flow velocity mapping is presented here. Instead of the conventional approach of employing two images (velocity sensitive and control) to generate velocity information, in the new method one determines the velocity directly from a single-shot acquisition by solving an inverse problem. This technique is a variant of single-shot parameter assessment by retrieval from signal encoding (SS-PARSE). The results of simulation and phantom studies show strong agreement with the actual velocities. The prototype method can measure velocities in the range of -50 to 50 cm/s, which is roughly appropriate for future applications in dynamic blood flow measurement in carotid arteries.

Algorithms↗

Magnetic resonance phase velocity mapping through NiTi stents in a flow phantom model.

PURPOSE: To assess constant and pulsatile flow velocity within the lumen of a peripheral NiTi stent using phase velocity mapping for comparison with independent assessments of flow velocity in a phantom model. MATERIALS AND METHODS: A 9 x 20-mm stent installed in flexible tubing was placed in a phantom filled with stationary fluid. Constant and pulsatile flow (produced by a pump programmed to produce a simulation of the carotid artery flow) was assessed using phase velocity mapping at 4.1 T (for constant flow) and at 1.5 T (for pulsatile flow). In all cases 256 x 256 gradient echo phase velocity maps were acquired. For the pulsatile flow condition, cine images with acquisition gated to the pump cycle were acquired with 40 msec temporal resolution across the simulated cardiac cycle. Computed flow volume rates were compared with fluid volume collection for the constant flow model, and with ultrasonic Doppler flow meter measurements for the pulsatile model. RESULTS: The data showed that volume flow rate assessments by phase velocity mapping agreed with independent measurements within 10% to 15%. CONCLUSION: Phase velocity mapping of the lumen of peripheral size NiTi stents is possible in an in vitro model.

Alloys↗

Evaluation of in-stent stenosis by magnetic resonance phase-velocity mapping in nickel-titanium stents.

PURPOSE: To evaluate different grades of in-stent stenosis in a nickel-titanium stent with MRI. MATERIALS AND METHODS: Magnetic resonance phase velocity mapping (MR-PVM) was used to measure flow velocity through a 9-mm NiTi stent with three different degrees of stenosis in a phantom study. The tested stenotic geometries were 1) axisymmetric 75%, 2) axisymmetric 90%, and 3) asymmetric 50%. The MR-PVM data were subsequently compared with the velocities from computational fluid dynamic (CFD) simulations of identical conditions. RESULTS: Good quantitative agreement in velocity distribution for the 50% and 75% stenoses was observed. The agreement was poor for the 90% stenosis, most likely due to turbulence and the high-velocity gradients found in the small luminal area relative to the pixel resolution in our imaging settings. CONCLUSION: The accuracy of the MRI velocities inside the stented area renders MRI a modality that may be used to assess moderate to severe in-stent restenosis (ISR) in medium-sized vascular stents in peripheral vessels, such as the iliac, carotid, and femoral arteries. Advances in MR instrumentation may provide sufficient resolution to obtain adequate velocity information from smaller vessels, such as the coronary arteries, and allow MRI to substitute for invasive and expensive catheterization procedures currently in clinical use.

Constriction, Pathologic↗

The impact of myocardial flow reserve on the detection of coronary artery disease by perfusion imaging methods: an NHLBI WISE study.

Myocardial flow reserve (MFR) is not routinely assessed in myocardial perfusion imaging (MPI) studies but has been hypothesized to affect test accuracy when assessing disease severity by coronary vessel lumenography. Magnetic resonance imaging (MRI) is an emerging diagnostic technique that can both perform MPI and assess MFR. We studied women (n = 184) enrolled in the Women's Ischemia Syndrome Evaluation (WISE) study with symptoms suggesting ischemic heart disease. Tests performed were coronary angiography and MPI by both MR and gated radionuclide single photon emission computed tomography (gated-SPECT). The MFR index was calculated using the MR data acquired at baseline and under vasodilation (dipyridamole) conditions. The study was structured with a pilot and an implementation phase. During the pilot phase (n = 46) data were unmasked and an MFR threshold was defined to divide patients into those with an adequate (AMFRI) or inadequate (IMFRI) MFR index. During the implementation phase, the MFR index threshold was prospectively applied to patients (n = 138). In the implementation phase, MPI ischemia detection accuracy compared to severe (> or = 70%) coronary artery diameter narrowing by angiography was higher in the AMFRI vs. the IMFRI group for MRI (86% vs. 70%, p < 0.05) and gated-SPECT (89% vs. 67%, p < 0.01). The IMFRI group (n = 55, 30% of study population) had a higher resting rate-pressure product compared with the AMFRI group (10,599 +/- 2871 vs. 9378 +/- 2447 bpm mm Hg, p < 0.01), consistent with higher resting myocardial flow. When compared with each other, MRI and gated-SPECT MPI showed no difference in accuracy among MFR groups. Myocardial perfusion patterns in the IMFRI group may have resulted in atypical perfusion patterns, which either masked or mimicked epicardial coronary artery disease.

Contrast Media↗

Effect of contrast agent viscosity and injection flow velocity on bolus injection pressures for peripheral venous injection in first-pass myocardial perfusion studies.

Myocardial perfusion imaging using Gd contrast agents is typically performed with bolus injections of the contrast agent using a power injector to provide for consistent and sufficiently rapid injection rates for all patients. For protocols in which a peripheral venous injection is called for (e.g. antecubital vein) injection catheters of 18 ga are used where vessel geometry permits. In some patients, particularly women with smaller veins, 20 and 22 ga catheters are used. The effect of catheter size and pressure tubing length can result in high injection pressures that occasionally cause leakage or connector failure. The viscosity of the contrast agent also impacts injection pressure. In this study, a simulation of the injection pathway was constructed with time resolved pressures measured at two points in the pathway. Pressure drops were calculated for a typical MR perfusion injection protocol.

Catheterization, Peripheral↗