Retrospective distortion correction for 3D MR diffusion tensor microscopy using mutual information and Fourier deformations.

Magnetic resonance diffusion tensor imaging (DTI) can be complicated by distortions that contribute to errors in tissue characterization and loss of fine structures. This work presents a correction scheme based on retrospective registration via mutual information (MI), using Fourier transform (FT)-based deformations to enhance the reliability of the entropy-based image registration. The registration methodology is applied to correct distortions in 3D high-resolution DTI datasets, incorporating a complete set of affine deformations. The results demonstrate that the proposed methodology can consistently and significantly reduce the number of misregistered pixels, leading to marked improvement in the visualization of internal brain white matter (WM) structure via DTI. Post-registration analysis revealed that eddy-current effects cannot fully account for the observed image distortions. Combined, these findings support the non-model-based, postprocessing approach for correcting distortions, and demonstrate the advantages of combining FT-based deformations and MI registration to enhance the practical utility of DTI.

Animals↗

MRI-based finite-element analysis of left ventricular aneurysm.

Tagged MRI and finite-element (FE) analysis are valuable tools in analyzing cardiac mechanics. To determine systolic material parameters in three-dimensional stress-strain relationships, we used tagged MRI to validate FE models of left ventricular (LV) aneurysm. Five sheep underwent anteroapical myocardial infarction (25% of LV mass) and 22 wk later underwent tagged MRI. Asymmetric FE models of the LV were formed to in vivo geometry from MRI and included aneurysm material properties measured with biaxial stretching, LV pressure measurements, and myofiber helix angles measured with diffusion tensor MRI. Systolic material parameters were determined that enabled FE models to reproduce midwall, systolic myocardial strains from tagged MRI (630 +/- 187 strain comparisons/animal). When contractile stress equal to 40% of the myofiber stress was added transverse to the muscle fiber, myocardial strain agreement improved by 27% between FE model predictions and experimental measurements (RMS error decreased from 0.074 +/- 0.016 to 0.054 +/- 0.011, P < 0.05). In infarct border zone (BZ), end-systolic midwall stress was elevated in both fiber (24.2 +/- 2.7 to 29.9 +/- 2.4 kPa, P < 0.01) and cross-fiber (5.5 +/- 0.7 to 11.7 +/- 1.3 kPa, P = 0.02) directions relative to noninfarct regions. Contrary to previous hypotheses but consistent with biaxial stretching experiments, active cross-fiber stress development is an integral part of LV systole; FE analysis with only uniaxial contracting stress is insufficient. Stress calculations from these validated models show 24% increase in fiber stress and 115% increase in cross-fiber stress at the BZ relative to remote regions, which may contribute to LV remodeling.

Animals↗

Accelerating MR diffusion tensor imaging via filtered reduced-encoding projection-reconstruction.

MR diffusion tensor imaging (DTI) is a promising tool for characterizing the microstructure of ordered tissues. However, its practical applications are hampered by relatively low signal-to-noise-ratio and spatial and temporal resolution. Reduced-encoding imaging (REI) via k-space sharing with constrained reconstruction has previously been shown to be effective for accelerating DTI, although the implementation was based on rectilinear k-space sampling. Due to the intrinsic oversampling of central k-space and allowance for isotropic downsampling, projection-reconstruction (PR) imaging may be better suited for REI. In this study, regularization procedures, including radial filtering and baseline signal correction to adequately reconstruct reduced encoded PR imaging data, are investigated. The proposed filtered reduced-encoding projection-reconstruction (FREPR) technique is applied to DTI tissue fiber orientation and fractional anisotropy (FA) measurements. Results show that FREPR offers improved reconstructions of the reduced encoded images and on an equal total scan-time basis provides more accurate fiber orientation and FA measurements compared to rectilinear k-space sampling-based REI methods or a control experiment consisting of only fully encoded images. These findings suggest a potentially significant role of FREPR in accelerating repeated imaging and improving the data acquisition-time efficiency of DTI experiments.

Computer Simulation↗

Noise removal in magnetic resonance diffusion tensor imaging.

Although promising for visualizing the structure of ordered tissues, MR diffusion tensor imaging (DTI) has been hampered by long acquisition time and low spatial resolution associated with its inherently low signal-to-noise ratio (SNR). Moreover, the uncertainty in the DTI measurements has a direct impact on the accuracy of structural renderings such as fiber streamline tracking. Noise removal techniques can be used to improve the SNR of DTI without requiring additional acquisitions, albeit most low-pass filtering methods are accompanied by undesirable image blurring. In the present study, a modified vector-based partial-differential-equation (PDE) filtering formalism was implemented for smoothing DTI vector fields. Using an image residual-energy criterion to equate the degree of smoothing and error metrics empirically derived from DTI data to quantify the relative performances, the effectiveness in denoising DTI data is compared among image-based and vector-based PDE and fixed and adaptive low-pass k-space filtering. The results demonstrate that the edge-preservation feature of the PDE approach can be highly advantageous in enhancing DTI measurements, particularly for vector-based PDE filtering in applications relying on DTI directional information. These findings suggest a potential role for the postprocessing enhancement technique to improve the practical utility of DTI.

Analysis of Variance↗

Helical myofiber orientation after myocardial infarction and left ventricular surgical restoration in sheep.

OBJECTIVES: It has been proposed that successful left ventricular surgical restoration should restore normal helical myofiber orientation. A magnetic resonance imaging technique, magnetic resonance diffusion tensor imaging, has been developed to measure myocyte orientation. By using magnetic resonance diffusion tensor imaging, this study tested the hypothesis that (1) myocyte orientation is altered after anteroapical myocardial infarction and (2) left ventricular surgical restoration restores normal helix angles. METHODS: Thirteen sheep underwent anteroapical myocardial infarction (25% of left ventricular mass). Ten weeks later, animals underwent either aneurysm plication (n = 8) or sham operations (n = 5). Six weeks after this operation, hearts were excised, perfusion fixed in diastole, and underwent magnetic resonance diffusion tensor imaging. Hearts from normal sheep (n = 5) were also harvested and imaged. Primary eigenvectors of the diffusion tensors from magnetic resonance diffusion tensor imaging were resolved into helix angles relative to a local wall coordinate system. Transmural samples of the helix angles were compared at the border zone of the aneurysm or repair (or a comparable distance from the base in normal sheep), 1 cm below the valves, and halfway between. RESULTS: The helical myofiber orientation did not change after myocardial infarction. However, aneurysm plication caused myofibers in the anterior border zone to rotate counterclockwise (-35.6 +/- 10.5 degrees , P = .028) and those in the lateral border zone to rotate clockwise (34.4 +/- 8.1 degrees , P = .031). CONCLUSIONS: Surgical restoration alters myocyte orientation adjacent to the surgical repair. However, myofiber orientation is not abnormal after myocardial infarction, and thus surgical restoration techniques intent on restoring normal helix angles might not be warranted.

Animals↗

Three-dimensional diffusion tensor microscopy of fixed mouse hearts.

The relative utility of 3D, microscopic resolution assessments of fixed mouse myocardial structure via diffusion tensor imaging is demonstrated in this study. Isotropic 100-microm resolution fiber orientation mapping within 5.5 degrees accuracy was achieved in 9.1 hr scan time. Preliminary characterization of the diffusion tensor primary eigenvector reveals a smooth and largely linear angular rotation across the left ventricular wall. Moreover, a higher level of structural hierarchy is evident from the organized secondary and tertiary eigenvector fields. These findings are consistent with the known myocardial fiber and laminar structures reported in the literature and suggest an essential role of diffusion tensor microscopy in developing quantitative atlases for studying the structure-function relationships of mouse hearts.

Animals↗

High-resolution determination of soft tissue deformations using MRI and first-order texture correlation.

Mechanical factors such as deformation and strain are thought to play important roles in the maintenance, repair, and degeneration of soft tissues. Determination of soft tissue static deformation has traditionally only been possible at a tissue's surface, utilizing external markers or instrumentation. Texture correlation is a displacement field measurement technique which relies on unique image patterns within a pair of digital images to track displacement. The technique has recently been applied to MR images, indicating the possibility of high-resolution displacement and strain field determination within the mid-substance of soft tissues. However, the utility of MR texture correlation analysis may vary amongst tissue types depending on their underlying structure, composition, and contrast mechanism, which give rise to variations in texture with MRI. In this study, we investigate the utility of a texture correlation algorithm with first-order displacement mapping terms for use with MR images, and suggest a novel index of image "roughness" as a way to decrease errors associated with the use of texture correlation for intra-tissue strain measurement with MRI. We find that a first-order algorithm can significantly reduce strain measurement error, and that an image "roughness" index correlates with displacement measurement error for a variety of imaging conditions and tissue types.

Algorithms↗

Region specific modeling of cardiac muscle: comparison of simulated and experimental potentials.

This article investigates the quantitative predictive capabilities of region-specific models by comparing experimental electrograms obtained from in vivo mapping of the ventricular free wall with those obtained through simulation of a region specific three-dimensional bidomain model that incorporates measured fiber orientations. Epicardial electrograms were recorded from canine left ventricles during and after unipolar pacing using a 528-channel electrode plaque. Fiber directions throughout the tissue were estimated from diffusion-weighted MRI and from pace mapping. Electrograms were computed in the bidomain model with experimentally derived properties during paced activations at the same spatiotemporal resolution as those recorded experimentally. Epicardial potentials from model and experiment were directly compared, and sensitivities of these comparisons to reference electrode location and to the choice of material properties were analyzed. The comparisons performed here demonstrate, that (1) the stimulus artifact can be used to estimate the in vivo myocardial fiber architecture, (2) the correlation between simulated and experimental electrograms decreases with increasing pacing depth, and (3) the quantitative comparisons between bidomain model and experimental data are sensitive to both the description of the fiber architecture, and the location of the unipolar reference electrode, but relatively insensitive to moderate changes in the bidomain conductivities.

Animals↗