Poly-L/D-lactide (PLDLA) 96/4 fibrous implants: histological evaluation in the subcutis of experimental design.

Poly-L/D-lactide (PLDLA) 96/4 fibrous implants have been introduced to engineer functional fibrous constructions in situ. The current study was undertaken to evaluate the guidance of the fibrous tissue formation and the tissue reaction of porous PLDLA 96/4 scaffolds implanted in subcutaneous tissue. Three various PLDLA 96/4 knitted-mesh scaffolds (Loose, Ordinary, and Dense) were implanted subcutaneously in 32 rats, and followed-up from 3 days until 48 weeks postsurgery. Histological examination showed that PLDLA 96/4 scaffolds provided a structurally supporting element for 48 weeks. They were filled with fibrous tissue by 3 weeks. During the follow-up, loose connective tissue was organized into dense connective tissue with thick collagen bundles. At 48 weeks, no statistically significant difference was found in the amount of loose or dense connective tissue between the scaffold groups of various porosities, although the tendency for higher amounts of loose connective tissue was seen in the Loose type scaffolds. PLDLA filament diameters were 121 mum at 2 weeks, 119 mum at 24 weeks and 116 mum at 48 weeks (P = 0.03 between 2 and 48 weeks). Porous PLDLA scaffold induced fibrous tissue formation in situ. This can be exploited in engineering fibrous tissue constructs in vivo for tissue support or replacement purposes.

Absorbable Implants↗

Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports.

We report our preliminary experience with 3 cases in which internal fixation with a self-reinforced poly-l/dl-lactide 70/30 miniplate and 1.5-mm or 2.0-mm screws were used to stabilize an open metacarpal fracture, a metacarpophalangeal arthrodesis in a thumb replantation, and an interposed bone graft for reconstruction of a thumb. Clinical and radiologic follow-up evaluation lasted for 12 to 20 months. Bone healing was uneventful in all 3 cases with no displacement or delayed union. The implants were biocompatible with no clinically manifested foreign body reaction. Because of the self-reinforcing manufacturing technique the plates have metal-like mechanical and handling properties. Complete late resorption makes self-reinforced poly-l/dl-lactide 70/30 miniplating systems an attractive alternative to metallic implants for skeletal stabilization of small bones of the hand.

Absorbable Implants↗

Bioabsorbable fixation devices in trauma and bone surgery: current clinical standing.

Bioabsorbable fixation devices are increasingly used in trauma, orthopedic and craniomaxillofacial surgery. The devices are essentially made of polylactic acid and/or polyglycolic acid polymers. Ultra-high-strength implants are manufactured from such polymers using self-reinforcing techniques. Implants are available for stabilization of fractures, osteotomies, bone grafts and fusions, as well as for reattachment of ligaments, tendons, meniscal tears and other soft tissue structures. As these implants are completely absorbed, the need for a removal operation is overcome and long-term interference with tendons, nerves and the growing skeleton is avoided. The risk of implant-associated stress shielding, peri-implant osteoporosis and infections is reduced. Implants do not interfere with clinical imaging. Current clinical use of bioabsorbable devices is reviewed.

Absorbable Implants↗

Bioabsorbable miniplating versus metallic fixation for metacarpal fractures.

Bioabsorbable implants offer an attractive alternative to metallic implants to stabilize small bone fractures in the hand. Self-reinforced bioabsorbable miniplating for metacarpal fractures was studied in bones from cadavers and compared with standard metallic fixation methods. One hundred twelve fresh-frozen metacarpals from humans had three-point bending and torsional loading after transverse osteotomy followed by fixation using seven methods: (1) dorsal and (2) dorsolateral 2-mm self-reinforced polylactide-polyglycolide 80/20 plating, (3) dorsal and (4) dorsolateral 2-mm self-reinforced poly-L/DL-lactide 70/30 plating, (5) dorsal 1.7-mm titanium plating, (6) dorsal 2.3-mm titanium plating, and (7) crossed 1.25-mm Kirschner wires. In apex dorsal and palmar bending, dorsal self-reinforced polylactide-polyglycolide and poly-L/DL-lactide plates provided stability comparable with dorsal titanium 1.7-mm plating. When the bioabsorbable plates were applied dorsolaterally, apex palmar rigidity was increased and apex dorsal rigidity was decreased. Bioabsorbable platings resulted in higher torsional rigidity than 1.7-mm titanium plating and in failure torque comparable with 2.3-mm titanium plating. Low-profile selfreinforced polylactide-polyglycolide and poly-L/DL-lactide miniplates provide satisfactory biomechanical stability for metacarpal fixation. These findings suggest that bioabsorbable miniplating can be used safely in the clinical stabilization of metacarpal and phalangeal fractures.

Absorbable Implants↗

Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.

Bioabsorbable fixation devices offer a useful option to treat small bone fractures of the hand if the prerequisite of reliable and stable osteofixation is met. We compared the stabilities of various bioabsorbable fixation devices with metallic fixation devices by using an oblique osteotomy model in radial to ulnar orientation. The 1.5-mm, self-reinforced, poly-L-lactide (SR-PLLA) pins provided fixation rigidity comparable with 1.5-mm K-wires in dorsal and palmar apex bending, whereas in lateral apex bending and in torsion the rigidity was equal to that of 1.25-mm K-wires. The 2.0-mm, self-reinforced, poly-L/DL-lactide (SR-P(L/DL)LA) 70/30 screws provided rigidity comparable with that of 1.5-mm K-wires in all testing modes. The bioabsorbable plate considerably enhanced the bending stabilities of the fixation system, but a single interfragmentary screw provided only limited rotational rigidity. The results show that by using ultra-high strength self-reinforced implants adequate fixation stability for hand fracture fixation can be achieved.

Absorbable Implants↗

Transphyseal bioabsorbable screws cause temporary growth retardation in rabbit femur.

A self-reinforced bioabsorbable poly-L-lactide/polyglycolide (SR-PLGA) 80/20 screw 2.0 mm in diameter was implanted transphyseally across the distal growth plate of the right femur in 24 immature rabbits. Radiologic evaluation revealed a mean shortening of 3.1 mm at 3 weeks, 11.1 mm at 6 weeks, 9.3 mm at 24 weeks, 9.0 mm at 48 weeks, and 12.6 mm at 72 weeks compared with the intact contralateral femur. In 13 control rabbits, drilling without screw placement did not cause any statistically significant femoral shortening. Therefore, the transphyseal SR-PLGA 80/20 screw caused growth retardation for 6 weeks postoperatively, after which the normal growth tendency was recovered until the growth plate was closed. The duration of temporary growth retardation correlated with that of strength retention of the SR-PLGA 80/20 copolymer. These findings suggest that SR-PLGA 80/20 screws can be applied in transphyseal bone fixation. The use of bioabsorbable screws for temporary epiphysiodesis seems attractive but requires further study.

Absorbable Implants↗