PubMed Health⌕ Search

Biomedical subjects

Egisto Boschetti

Publications and source records attributed to Egisto Boschetti.

13 recordsLinked to original sources

Reducing protein concentration range of biological samples using solid-phase ligand libraries.

The discovery of specific polypeptides of diagnostic relevance from a biological liquid is complicated by the overall vast number and the large concentration range of all polypeptides/proteins in the sample. Depletion or fractionation methodologies have been used for selectively removing abundant proteins; however, they failed to significantly enrich trace proteins. Here we expand upon a new method that allows the reduction of the protein concentration range within a complex mixture, like neat serum, through the simultaneous dilution of high abundance proteins and the concentration of low abundance ones in a single, simple step. This methodology utilizes solid-phase ligand libraries of large diversity. With a controlled sample-to-ligand ratio it is possible to modulate the relative concentration of proteins such that a large number of peptides or proteins that are normally not detectable by classical analytical methods become, easily detectable. Application of this method for reducing the dynamic range of unfractionated serum is specifically described along with treatment of other biological extracts. Analytical surface enhanced laser desorption/ionization mass spectrometry (SELDI-MS) technology and mono- and two-dimensional electrophoresis (1-DE and 2-DE) demonstrate the increase in the number of proteins detected. Examples linking this approach with additional fractionation methods demonstrate a further increase in the number of detectable species using either the so-called "top down" or "bottom up" approaches for proteomics analysis. By enabling the detection of a greater proportion of polypeptides/proteins within a sample, this method may contribute significantly towards the discovery of new biomarkers of diagnostic relevance.

Chromatography, Ion Exchange↗

A new approach for the removal of protein impurities from purified biologicals using combinatorial solid-phase ligand libraries.

The removal of last impurity traces from a purified protein is generally called polishing. It is an important step in downstream processing since protein impurities may generate undesirable side effects when the preparation is intended for research, diagnostic and more importantly therapeutic applications. Polishing is generally achieved by using orthogonal separation methods to previous steps, the most common being gel permeation chromatography. In spite of its polishing effectiveness, this technique suffers from a poor separation capacity and modest productivity as a result of low speed. Other approaches, for instance, based on anion exchange or on hydrophobic chromatography, that may be optimized for a given process cannot be used as generic methods. This document reports for the first time the use of a combinatorial solid-phase peptide library as a general method for the removal of impurity traces. Several examples of impurity trace removal are reported; starting material is either a pure protein spiked with serum proteins or with Escherichia coli extracts or current purified proteins still containing a small percentage of impurities. Among polished proteins are recombinant human albumin expressed in Pichia pastoris and human transferrin purified from whole plasma. This new method is used in neutral or even physiological pH and ionic strength conditions, with a remarkable capability to remove impurities. The process is as rapid as current adsorption chromatography procedures usable for the removal of a large number of protein impurities, with each one present in small amounts, such as host cell proteins.

Biological Products↗

Protein Equalizer Technology : the quest for a "democratic proteome".

No proteome can be considered "democratic", but rather "oligarchic", since a few proteins dominate the landscape and often obliterate the signal of the rare ones. This is the reason why most scientists lament that, in proteome analysis, the same set of abundant proteins is seen again and again. A host of pre-fractionation techniques have been described, but all of them, one way or another, are besieged by problems, in that they are based on a "depletion principle", i.e. getting rid of the unwanted species. Yet "democracy" calls not for killing the enemy, but for giving "equal rights" to all people. One way to achieve that would be the use of "Protein Equalizer Technology" for reducing protein concentration differences. This comprises a diverse library of combinatorial ligands coupled to spherical porous beads. When these beads come into contact with complex proteomes (e.g. human urine and serum, egg white, and any cell lysate, for that matter) of widely differing protein composition and relative abundances, they are able to "equalize" the protein population, by sharply reducing the concentration of the most abundant components, while simultaneously enhancing the concentration of the most dilute species. It is felt that this novel method could offer a strong step forward in bringing the "unseen proteome" (due to either low abundance and/or presence of interference) within the detection capabilities of current proteomics detection methods. Examples are given of equalization of human urine and serum samples, resulting in the discovery of a host of proteins never reported before. Additionally, these beads can be used to remove host cell proteins from purified recombinant proteins or protein purified from natural sources that are intended for human consumption. These proteins typically reach purities of the order of 98%: higher purities often become prohibitively expensive. Yet, if incubated with "equalizer beads", these last impurities can be effectively removed at a small cost and with minute losses of the main, valuable product.

Biomarkers↗

A new approach for the detection and identification of protein impurities using combinatorial solid phase ligand libraries.

We propose a novel method for detection of protein impurities present in plasma-derived and recombinant purified injectable biopharmaceuticals by enhancing the concentration of protein impurities, in essence "amplifying" their presence to detectable levels. The method is based on the capture of proteins using a combinatorial solid-phase hexapeptides ligand library previously described for the reduction of protein concentration difference in biological fluids. Three proteins have been investigated: Staphylococcus aureus Protein A, expressed in Escherichia coli and supplied as 99% pure, recombinant human albumin, expressed in Pichia pastoris and certified as 95% pure, and therapeutic albumin supplied as 96-98% pure injectable solution. In all cases, after treatment with the ligand libraries, a number of additional polypeptide chains, not visible in the control, could be detected and obtained in sufficient amounts for MS analysis. In the cases of the two recombinant proteins, it could be demonstrated that a number of these polypeptide chains were host cell proteins still present in the purified product. In addition, a substantial number of these spots were found to be cleavage products of the original recombinant DNA species. Such cleavage products were particularly abundant in the recombinant human albumin preparation. From pure injectable serum albumin, a number of human plasma protein impurities were also identified by LC-MS/MS analysis. Treatment with ligand libraries of purified proteins is thus seen as a very powerful method of capture and concentration of host proteins and cleaved products for further analysis to control better the quality of industrial biotechnology products.

Albumins↗

Proteome analysis in the clinical chemistry laboratory: myth or reality?

BACKGROUND: We review here modern aspects of proteomic analysis, as displayed via orthogonal mass/charge analysis (isoelectric focusing in the first dimension, followed by sodium dodecyl sulphate electrophoresis in polyacrylamide gels, SDS-PAGE, at right angles, in the second dimension). METHODS: This technique is capable of displaying a few thousand polypeptide chains, characterized by a single pI and M(r) value as coordinates, and recognized via elution, digestion and mass spectrometry analysis. Although, up to the present, this technique has been used mostly for advanced research, with no immediate applications in the clinical chemistry laboratory, there are hints that such applications will soon become a reality. RESULTS AND CONCLUSIONS: In the field of cancer research, it is here shown that stathmin (Op18) becomes heavily phosphorylated in cancerous mantle cell lymphomas and that the progression of the disease can be followed by the progression of phosphorylation of Op18 and by the appearance of additional phosphorylated spots. Also chemoresistance of different tumors has been evaluated via 2D-PAGE through quantitative, differential proteomics: among up- and down-regulated proteins in a human cervix squamous cell carcinoma cell line (A431), rendered resistant to cisplatin, one particular protein was found to appear in large quantities by de novo synthesis: 14-3-3, a protein known to impart resistance to apoptosis to cells. In the field of brain disorders, we could set up an easy test for detecting pathological prions in sporadic Creutzfeldt-Jakob disease (sCJD), by simply searching for those pathological forms in the olfactory mucosa (up to this finding, diagnosis could only be confirmed post-mortem). We are currently working on a test for differentiating sCJD from all the other degenerative dementias. Upon 2D mapping of cerebrospinal fluid (CSF) and immunoblot analysis, we could identify a major spot (pI 4.8, M(r) 30 kDa) followed by some two-three minor spots (pIs 5.0-6.0, same M(r) value) of the same 14-3-3 anti-apoptotic protein involved in chemoresistance. By this test, sCJD could be differentiated from all the other degenerative dementias, which are 14-3-3 negative (in sCJD, the rapid and massive brain cell damage releases large quantities of 14-3-3 in the cerebrospinal fluid). Another protein that appears very promising as a marker for sCJD is cystatin C, that is strongly up-regulated in this pathology. Human sera should also be mined for discovery of many more markers for disease. Up to the present, no one could be found, but this was due to the presence of several major proteins, obscuring all rare ones. Via several immuno-subtraction steps, followed by ion exchange and size exclusion chromatography, one can now detect proteins and peptides present in sera at levels below 10 ng/mL, highlighting the road to discovery of novel markers of disease. Another technique that could revolutionize biomarker discovery in biological fluids consists in the use of combinatorial beads to reduce the dynamic range. They consist in a library of combinatorial ligands coupled to small beads. Such a library comprises hexameric ligands composed of amino acids, resulting in millions different structures. When these beads are impregnated with complex proteomes (e.g., human sera, CSF, urines) of widely differing protein compositions, they are able to significantly reduce the concentration differences, thus greatly enhancing the possibility of evidencing low-abundance species.

Animals↗

Capture of a monoclonal antibody and prediction of separation conditions using a synthetic multimodal ligand attached on chips and beads.

A synthetic ligand called 2-mercapto-5-benzimidazolesulfonic acid has been successfully used for the specific chromatographic capture of antibodies from a cell culture supernatant. Adsorption occurred at physiological ionic strength and pH range between 5.0 and 6.0, with some binding capacity variations within this pH range: antibody uptake increased when the pH decreased. With very dilute feedstocks, as was the case with the cell culture supernatant under investigation, it was found that the pH had to be slightly lowered to get a good antibody sorption capacity. To optimize separation conditions, a preliminary study was made using ProteinChip Arrays that displayed the same chemical functionalities as the resin. Arrays were analyzed using SELDI-MS. By this mean, it was possible to cross-over simultaneously different pH conditions at the adsorption and the desorption steps. Best conditions were implemented for preparative separation using regular lab-scale columns. At pH 5.2, antibody adsorption was not complete, while at pH 5.0 the antibody was entirely captured. pH 9 was selected at elution, rather than pH 8.0 or 10.0, and resulted in a complete desorption of antibodies from the column. Benefits of the prediction of separation conditions of antibodies on MBI beads using SELDI-MS were a significant reduction in analysis time and in sample volume. This was possible because the separation of IgG on the chip surface did mimic very well the separation on beads.

Adsorption↗

Prefractionation techniques in proteome analysis: the mining tools of the third millennium.

The present review deals with prefractionation protocols used in proteomic investigation in preparation for mass spectrometry (MS) or two-dimensional electrophoresis (2-DE) map analysis. Briefly, reported methods focus on cell organelle differential centrifugation and on chromatographic approaches, to continue in extenso with a panoply of electrophoretic methods. In the case of chromatography, procedures useful as a prefractionation step, including affinity, ion-exchange, and reversed-phase resins, revealed several hundreds of new species, previously undetected in unfractionated samples. Novel chromatographic prefractionation methods are also discussed such as a multistaged fractionation column, consisting in a set of immobilized chemistries, serially connected in a stack format (an assembly of seven blocks), each capable of harvesting a given protein population. Such a method significantly simplifies the complexity of treated samples while concentrating species, all resulting in a larger number of visible proteins by MS or 2-DE. Electrophoretic prefractionation protocols include all those electrokinetic methodologies which are performed in free solution, essentially all relying on isoelectric focusing steps (although some approaches based on gels and granulated media are also discussed). Devices associated with electrophoretic separation are multichamber apparatus, such as the multicompartment electrolyzers equipped with either isoelectric membranes or with isoelectric beads. Multicup device electrophoresis and several others, exploiting the conventional technique of carrier ampholyte focusing, are reviewed. This review also reports approaches for sample treatments in order to detect low-abundance species. Among others, a special emphasis is made on the reduction of concentration difference between proteins constituting a sample. This latter consists in a library of combinatorial ligands coupled to small beads. Such a library comprises hexameric ligands composed of 20 amino acids, resulting in millions of different structures. When these beads are impregnated with complex proteomes (e.g., human sera) of widely differing protein compositions, they are able to significantly reduce the concentration differences, thus greatly enhancing the possibility to evidence low-abundance species. It is felt that this panoply of methods could offer a strong step forward in "mining below the tip of the iceberg" for detecting the "unseen proteome".

Cell Fractionation↗

Reduction of the concentration difference of proteins in biological liquids using a library of combinatorial ligands.

The discovery of polypeptides and proteins with relevance to a particular biological state is complicated by their vast number and concentration range in most biological mixtures. Depletion methodologies are frequently used to remove the most abundant species; however, this removal not only fails significantly to enrich trace proteins, it may also nonspecifically deplete them due to their interactions with the removed high-abundance proteins. Here we report a simple-to-use methodology that reduces the protein concentration range of a complex mixture like whole serum through the simultaneous dilution of high-abundance proteins and the concentration of low-abundance proteins. This methodology utilizes solid-phase ligand libraries of immense diversity, generated by "split, couple, recombine" combinatorial chemistry, that are used for affinity-based binding to the proteins of a given mixture. With a controlled sample-to-ligand ratio it is possible to modulate the relative concentration of proteins such that many peptides or proteins that are undetectable by classical analytical methods become easily accessible. The reduction in the dynamic range of unfractionated serum is specifically described along with treatment of other proteomes such as extracts from Escherichia coli, chicken egg white and cell culture supernatant. Mono- and bi-dimensional electrophoresis (1-DE and 2-DE respectively) and surface-enhanced laser desorption/ionization-mass spectrometry (SELDI-TOF-MS) technology demonstrate the reduction in protein concentration range. Combining this approach with additional fractionation methods further increased the number of detectable species.

Adsorption↗

Isoelectric beads for proteome pre-fractionation. II: experimental evaluation in a multicompartment electrolyzer.

Proteome pre-fractionation in multicompartment electrolyzers is proposed here, with substantial modifications as compared to the standard technique. First of all, the classical isoelectric, buffering membranes, delimiting each compartment and acting, in pairs, as isoelectric traps, have been replaced by isoelectric buffering beads, operating on the same principle, but allowing unhindered migration of proteins (lack of sieving properties, contrary to typical continuous membrane barriers). Secondly, the isoelectric beads are not made in the conventional manner, with ionic acrylamide derivative monomers throughout their central core, but are composed of a hard, ceramic core, coated with an amphoteric buffering polymer. This minimizes mass transfer resistance of proteins that are transiently adsorbed onto the beads. As a result, significantly reduced separation times, of the order of ca. 3 h, are required for developing steady-state patterns, as compared to the lengthy times (overnight and much longer) in conventional multicompartment electrolyzers operating with isoelectric membranes. Examples of separation of standard marker proteins, as well as entire Escherichia coli lysates and human serum proteins, are given. The obtained fractions are analyzed by sodium dodecyl sulfate polyacrylamide gel electrophoresis, two-dimensional gel electrophoresis and by surface enhanced laser desorption/ionization mass spectrometry.

Blood Proteins↗

Amphoteric, buffering chromatographic beads for proteome prefractionation. I: theoretical model.

The possibility is reported here of fractionating proteins on amphoteric, buffering resins via ion-exchange chromatography. A given protein's adsorption to a particular amphoteric buffering resin is characterized by a bell-shaped curve in which the maximum protein binding capacity is observed at an optimum pH value lying approximately midway between the isoelectric point values (pI) of the resin and the protein. On either side of this maximum the protein binding capacity declines steadily, reaching zero at the pI of either the protein or exchanger. For instance, on beads of pI equal to 8, four proteins, two acidic (bovine albumin and ovalbumin) and two basic (cytochrome c and lysozyme), exhibit binding curves reaching zero values for the whole set when the exchanger is conditioned at pH 8.0. Away from the pI, and on both sides of the pH scale, the bell-shaped adsorption curves reach a maximum, for each protein, at a pH located at the midpoint between the pI values of each protein and that of the exchanger, and decline steadily to reach zero at the pI value of each protein species. Separation of model proteins using different amphoteric buffering resins of various pI was possible at different pH values according to both the pI of the proteins and of the exchangers. It was also demonstrated, using surface enhanced laser desorption/ionization mass spectrometry and two dimensional electrophoretic mapping, that separation of an Escherichia coli cell lysate on columns packed with amphoteric buffering resins of different pI and titrated to a particular pH value, delivered two distinctly different fractions, i.e. characteristically composed of, on the one hand, proteins having a pI below the buffer pH (the 'adsorbed' fraction), and on the other, of alkaline proteins possessing a pI above the pH of the buffer (the 'unadsorbed' fraction). This approach represents an attractive addition and/or alternative to the armory of protein pre-fractionation techniques currently employed in proteomics.

Albumins↗

Endostatin capture from Pichia pastoris culture in a fluidized bed. From on-chip process optimization to application.

One of the characteristics of the methylothrophic yeast Pichia pastoris is its ability to grow to a very high cell density. Biomass concentrations of 300-400 g wet mass/l are common. It is therefore obvious that the recovery processes of extracellular proteins from this microorganism should take into account the effect of high biomass content. Separation by filtration and/or centrifugation is possible but these steps are cumbersome and can affect the protein recovery. The use of fluidized beds is attractive proteins capture option since it eliminates the biomass while capturing the desired protein. Zirconia-based resins possess unique properties which make them appropriate for processing high biomass concentrations in an expanded bed mode. The beads are particularly heavy (density is 3.2 g/ml) and small (75 microm) and therefore can accommodate high fluidization velocity and high mass transport. Specific operating conditions for effective capture of expressed protein have to be determined. This determination is generally time consuming and requires relatively large amount of feedstock for the lab trials. To avoid multiple chromatographic trials in columns, optimal conditions of adsorption and elution were determined by ProteinChip technology coupled with mass spectrometry. This technology involves flat chip surfaces functionalized as chromatographic beads where it is possible to adsorb and desorb proteins. Four different functional groups (strong anion-exchange, weak cation-exchange, hydrophobic and metal chelate) were tested and the retained proteins were analyzed directly by mass spectrometry. The weak cation-exchange group was chosen for further work. The Zirconia-based weak cation-exchange sorbent (CM HyperZ) was evaluated for binding capacity in a packed column and then for capturing endostatin from crude feed stock. Based on the previously determined conditions; 45 l of culture containing approximately 15 kg of biomass (wet mass) and 3 g endostatin were applied on an expanded bed at a flow-rate of 535 cm/h, yielding 80% of the endostatin and removing approximately 80% of foreign proteins.

Cation Exchange Resins↗

Antibody separation by hydrophobic charge induction chromatography.

Hydrophobic charge induction chromatography using 4-mercapto-ethyl-pyridine as the ligand is an effective method for the separation of antibodies from a variety of feedstocks. Antibodies are adsorbed in physiological conditions without preliminary concentration. Desorption occurs when the pH is lowered, thus inducing an ionic charge of the same sign to the ligand and the antibody. Antibody capture conditions are compatible with crude samples in terms of pH, conductivity, binding capacity and expression level. The final purity of the antibody is feedstock dependent, but can reach levels of purity as high as 98%. Examples of antibody separation are given and ligand structure information discussed.

Antibodies↗

Exploring the hidden human urinary proteome via ligand library beads.

The human urinary proteome has been reassessed and re-evaluated via a novel concentration/equalization technique, exploiting beads coated with hexameric peptide ligand libraries. These beads act by capturing the whole protein spectra contained in the sample, by drastically reducing the level of the most abundant species, while strongly concentrating the more dilute and rare ones. In a control urine sample, 134 unique proteins could be identified. The first bead eluate (in thiourea, urea, and CHAPS) permitted the identification of 317 gene products, whereas the second eluate (in 9 M urea, pH 3.8) allowed the identification of another 95 unique proteins. By eliminating redundancies, a total of 383 unique gene products could be identified in human urines. This represents a major increment as compared to data reported in recent literature. By comparing our data with those reported to the present, an additional 251 proteins could be added to the list, thus bringing the total unique gene products so far identified in human urines to ca. 800 species.

Adult↗