Visual assessment of angular response in medical liquid crystal displays.

In spite of having non-Lambertian emission, displays based on liquid crystal technology are becoming popular for medical diagnostic work stations. For all liquid crystal displays (LCDs), the contrast performance varies with viewing direction. Accurate measurements of the angular distribution of light emission require expensive instrumentation and extensive expertise. We investigated the possibility of using a test pattern to visually assess the angular response performance of LCDs. We found that this procedure offers the end user of displays a simple, fast, and relatively consistent technique to verify that the viewing angle performance of the display device is within certain acceptable limits.

Computer Peripherals↗

Simulation of mammographic lesions.

RATIONALE AND OBJECTIVES: This study presents a method for generating breast masses and microcalcifications in mammography via simulation. This simulation method allows for the creation of large image datasets with particular lesions, which may serve as a useful tool for perception studies measuring imaging system performance. MATERIALS AND METHODS: The study first characterized the radiographic appearance of both masses and microcalcifications, examining the following five properties: contrast, edge gradient profile of masses, edge characteristics of masses, shapes of individual microcalcifications, and shapes of microcalcification distributions. The characterization results then guided the development of routines that created simulated masses and microcalcifications. The quality of the simulations was verified by experienced breast imaging radiologists who evaluated simulated and real lesions and rated whether a given lesion had a realistic appearance. RESULTS: The radiologists rated real and simulated lesions to have similarly realistic appearances. Using receiver operating characteristic analysis to characterize the degree of similarity, the results showed an A(z) of 0.68 +/- 0.07 for benign masses, 0.65 +/- 0.07 for malignant masses, and 0.62 +/- 0.07 for microcalcifications, thus showing notable overlap in the simulated and real lesion ratings. CONCLUSION: This research introduced a new approach for simulating breast masses and microcalcifications that relied on anatomic characteristics measured from real lesions. Results from an observer performance experiment indicate that our simulation routine produced realistic simulations of masses and microcalcifications as judged by expert radiologists.

Breast Diseases↗

Comparison of LCD and CRT displays based on efficacy for digital mammography.

RATIONALE AND OBJECTIVES: To compare two display technologies, cathode ray tube (CRT) and liquid crystal display (LCD), in terms of diagnostic accuracy for several common clinical tasks in digital mammography. MATERIALS AND METHODS: Simulated masses and microcalcifications were inserted into normal digital mammograms to produce an image set of 400 images. Images were viewed on one CRT and one LCD medical-quality display device by five experienced breast-imaging radiologists who rated the images using a categorical rating paradigm. The observer data were analyzed to determine overall classification accuracy, overall lesion detection accuracy, and accuracy for four specific diagnostic tasks: detection of benign masses, malignant masses, and microcalcifications, and discrimination of benign and malignant masses. RESULTS: Radiologists had similar overall classification accuracy (LCD: 0.83 +/- 0.01, CRT: 0.82 +/- 0.01) and lesion detection accuracy (LCD: 0.87 +/- 0.01, CRT: 0.85 +/- 0.01) on both displays. The difference in accuracy between LCD and CRT for the detection of benign masses, malignant masses, and microcalcifications, and discrimination of benign and malignant masses was -0.019 +/- 0.009, 0.020 +/- 0.008, 0.012 +/- 0.013, and 0.0094 +/- 0.011, respectively. Overall, the two displays did not exhibit any statistically significant difference (P > .05). CONCLUSION: This study explored the suitability of two different soft-copy displays for the viewing of mammographic images. It found that LCD and CRT displays offer similar clinical utility for mammographic tasks.

Breast Neoplasms↗

Resolution and noise measurements of five CRT and LCD medical displays.

The performance of soft-copy displays plays a significant role in the overall image quality of a digital radiographic system. In this work, we discuss methods to characterize the resolution and noise of both cathode ray tube (CRT) and liquid crystal display (LCD) devices. We measured the image quality of five different commercial display devices, representing both CRT and LCD technologies, using a high-quality charge-coupled device (CCD) camera. The modulation transfer function (MTF) was calculated using the line technique, correcting for the MTF of the CCD camera and the display pixel size. The normalized noise power spectrum (NPS) was computed from two-dimensional Fourier analysis of uniform images. To separate the effects of pixel structure from interpixel luminance variations, we created structure-free images by eliminating the pixel structures of the display device. The NPS was then computed from these structure-free images to isolate interpixel luminance variations. We found that the MTF of LCDs remained close to the theoretical limit dictated by their inherent pixel size (0.85 +/- 0.08 at Nyquist frequency), in contrast to the MTF for the two CRT displays, which dropped to 0.15 +/- 0.08 at the Nyquist frequency. However, the NPS of LCDs showed significant peaks due to the subpixel structure, while the NPS of CRT displays exhibited a nearly flat power spectrum. After removing the pixel structure, the structured noise peaks for LCDs were eliminated and the overall noise magnitude was significantly reduced. The average total noise-to-signal ratio for CRT displays was 6.55% +/- 0.59%, of which 6.03% +/- 0.24% was due to interpixel luminance variations, while LCD displays had total noise to signal ratios of 46.1% +/- 5.1% of which 1.50% +/- 0.41% were due to interpixel luminance variations. Depending on the extent of the blurring and prewhitening processes of the human visual system, the magnitude of the display noise (including pixel structure) potentially perceived by the observer was reduced to 0.43% +/- 0.01% (accounting for blurring only) and 0.40 +/- 0.01% (accounting for blurring and prewhitening) for CRTs, and 1.02% +/- 0.22% (accounting for blurring only) and 0.36% +/- 0.08% (accounting for blurring and prewhitening) for LCDs.

Algorithms↗

Viewing angle performance of medical liquid crystal displays.

Cathode-ray tube (CRT) and liquid crystal display (LCD) are currently two main technologies for displaying medical images. LCDs possess a number of advantages, but their performance varies as a function of viewing angle. Our purpose in this study was to characterize the angular response performance of five medical-grade LCDs, and to substantiate their impact on their compliance with the DICOM gray scale display function (GSDF). Furthermore, the study aimed to test a framework to define an angular acceptance range for medical LCDs based on the recent AAPM TG18 guidelines. Measurements were made on five calibrated dual-domain LCDs, including two 3 megapixel monochrome LCDs, two 5 megapixel monochrome LCDs, and one 9 megapixel color LCD. The luminance performance of each display device was measured as a function of the viewing angle at 17 discrete levels using TG18-LN test patterns and a Fourier-optics-based luminance meter. The luminance data were analyzed according to the AAPM TG18 methodology. The displays showed notable variation in luminance and contrast performance as a function of the viewing angle, particularly in diagonal viewing orientations. Overall, the luminance ratio remained greater than 175 within +/-20 degrees and +/-33 degrees viewing angle cones (beta175 = 20 degrees-33 degrees). Aiming to maintain a maximum deviation from the GSDF contrast less than 0.3, i.e., kappa17 < or = 0.3, acceptable viewing angle cones of +/-22 degrees and +/-35 degrees were indicated (alpha 0.3= 22 degrees-35 degrees). The findings demonstrate the significant impact of angular response on image contrast, and the utility of alpha 0.3 and beta175 quantities for defining the viewing angle cones within which a medical LCD device can be effectively utilized.

Beta Particles↗

Imaging properties of digital magnification radiography.

Flat panel detectors exhibit improved signal-to-noise ratio (SNR) and display capabilities compared to film. This improvement necessitates a new evaluation of optimal geometry for conventional projection imaging applications such as digital projection mammography as well as for advanced x-ray imaging applications including cone-beam computed tomography (CT), tomosynthesis, and mammotomography. Such an evaluation was undertaken in this study to examine the effects of x-ray source distribution, inherent detector resolution, magnification, scatter rejection, and noise characteristics including noise aliasing. A model for x-ray image acquisition was used to develop generic results applicable to flat panel detectors with similar x-ray absorption characteristics. The model assumed a Gaussian distribution for the focal spot and a rectangular distribution for a pixel. A generic model for the modulated transfer function (MTF) of indirect flat panel detectors was derived by a nonlinear fit of empirical receptor data to the Burgess model for phosphor MTFs. Noise characteristics were investigated using a generic noise power spectrum (NPS) model for indirect phosphor-based detectors. The detective quantum efficiency (DQE) was then calculated from the MTF and NPS models. The results were examined as a function of focal spot size (0.1, 0.3, and 0.6 mm) and pixel size (50, 100, 150, and 200 microm) for magnification ranges 1 to 3. Mammography, general radiography (also applicable to mammotomography), and chest radiography applications were explored using x-ray energies of 28, 74, and 120 kVp, respectively. Nodule detection was examined using the effective point source scatter model, effective DQE, and the Hotelling SNR2 efficiency. Results indicate that magnification can potentially improve the signal and noise performance of digital images. Results also show that a cross over point occurs in the spatial frequency above and below which the effects of magnification differ indicating that there are task dependent tradeoffs associated with magnification. The cross over point varies depending upon focal spot size, pixel size, x-ray energy, and source-to-image-distance (SID). For mammography, the cross over point occurs for a 0.3 mm focal spot while a 0.6 mm focal spot indicates that magnification does not improve image quality due to focal spot blurring. Thus, the benefit of magnification may be limited. For general radiography (as well as mammotomography), and chest radiography, the cross over point changes with SID. For a system with a 0.3 mm focal spot, 100 microm pixel size, a 2 m SID, and the applicable tissue thickness and scatter components, optimal magnification improved SNR2 by approximately 1.2 times for mammography and 1.5 times for general radiography (and mammotomography). These results indicate that the optimal geometry can improve image quality without changing patient dose or otherwise reduce dose without compromising image quality.

Algorithms↗

Intercomparison of methods for image quality characterization. I. Modulation transfer function.

The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of the results. As a part of a study aimed at comparing the relative performance of different techniques, in this paper we report on a comparison of two established MTF measurement techniques: one using a slit test device [Dobbins et al., Med. Phys. 22, 1581-1593 (1995)] and another using a translucent edge test device [Samei et al., Med. Phys. 25, 102-113 (1998)], with one another and with a third technique using an opaque edge test device recommended by a new international standard (IEC 62220-1, 2003). The study further aimed to substantiate the influence of various acquisition and processing parameters on the estimated MTF. The slit test device was made of 2 mm thick Pb slabs with a 12.5 microm opening. The translucent edge test device was made of a laminated and polished Pt(0.9)Ir(0.1). alloy foil of 0.1 mm thickness. The opaque edge test device was made of a 2 mm thick W slab. All test devices were imaged on a representative indirect flat-panel digital radiographic system using three published beam qualities: 70 kV with 0.5 mm Cu filtration, 70 kV with 19 mm Al filtration, and 74 kV with 21 mm Al filtration (IEC-RQA5). The latter technique was also evaluated in conjunction with two external beam-limiting apertures (per IEC 62220-1), and with the tube collimator limiting the beam to the same area achieved with the apertures. The presampled MTFs were deduced from the acquired images by Fourier analysis techniques, and the results analyzed for relative values and the influence of impacting parameters. The findings indicated that the measurement technique has a notable impact on the resulting MTF estimate, with estimates from the overall IEC method 4.0% +/- 0.2% lower than that of Dobbins et al. and 0.7% +/- 0.4% higher than that of Samei et al. averaged over the zero to cutoff frequency range. Over the same frequency range, keeping beam quality and limitation constant, the average MTF estimate obtained with the edge techniques differed by up to 5.2% +/- 0.2% from that of the slit, with the opaque edge providing lower MTF estimates at lower frequencies than those obtained with the translucent edge or slit. The beam quality impacted the average estimated MTF by as much as 3.7% +/- 0.9% while the use of beam limiting devices alone increased the average estimated MTF by as much as 7.0% +/- 0.9%. While the slit method is inherently very sensitive to misalignment, both edge techniques were found to tolerate misalignments by as much as 6 cm. The results suggest the use of the opaque edge test device and the tube internal collimator for beam limitation in order to achieve an MTF result most reflective of the overall performance of the imaging system and least susceptible to misalignment and scattered radiation. Careful attention to influencing factors is warranted to achieve accurate results.

Algorithms↗

Intercomparison of methods for image quality characterization. II. Noise power spectrum.

Second in a two-part series comparing measurement techniques for the assessment of basic image quality metrics in digital radiography, in this paper we focus on the measurement of the image noise power spectrum (NPS). Three methods were considered: (1) a method published by Dobbins et al. [Med. Phys. 22, 1581-1593 (1995)], (2) a method published by Samei et al. [Med. Phys. 30, 608-622 (2003)], and (3) a new method sanctioned by the International Electrotechnical Commission (IEC 62220-1, 2003), developed as part of an international standard for the measurement of detective quantum efficiency. In addition to an overall comparison of the estimated NPS between the three techniques, the following factors were also evaluated for their effect on the measured NPS: horizontal versus vertical directional dependence, the use of beam-limiting apertures, beam spectrum, and computational methods of NPS analysis, including the region-of-interest (ROI) size and the method of ROI normalization. Of these factors, none was found to demonstrate a substantial impact on the amplitude of the NPS estimates (< or = 3.1% relative difference in NPS averaged over frequency, for each factor considered separately). Overall, the three methods agreed to within 1.6% +/- 0.8% when averaged over frequencies > 0.15 mm(-1).

Algorithms↗

Contrast-detail analysis of three flat panel detectors for digital radiography.

In this paper we performed a contrast detail analysis of three commercially available flat panel detectors, two based on the indirect detection mechanism (GE Revolution XQ/i, system A, and Trixell/Philips Pixium 4600, system B) and one based on the direct detection mechanism (Hologic DirectRay DR 1000, system C). The experiment was conducted using standard x-ray radiation quality and a widely used contrast-detail phantom. Images were evaluated using a four alternative forced choice paradigm on a diagnostic-quality softcopy monitor. At the low and intermediate exposures, systems A and B gave equivalent performances. At the high dose levels, system A performed better than system B in the entire range of target sizes, even though the pixel size of system A was about 40% larger than that of system B. At all the dose levels, the performances of the system C (direct system) were lower than those of system A and B (indirect systems). Theoretical analyses based on the Perception Statistical Model gave similar predicted SNRT values corresponding to an observer efficiency of about 0.08 for systems A and B and 0.05 for system C.

Contrast Media↗

Optimized radiographic spectra for small animal digital subtraction angiography.

The increasing use of small animals in basic research has spurred interest in new imaging methodologies. Digital subtraction angiography (DSA) offers a particularly appealing approach to functional imaging in the small animal. This study examines the optimal x-ray, molybdenum (Mo) or tungsten (W) target sources, and technique to produce the highest quality small animal functional subtraction angiograms in terms of contrast and signal-difference-to-noise ratio squared (SdNR2). Two limiting conditions were considered-normalization with respect to dose and normalization against tube loading. Image contrast and SdNR2 were simulated using an established x-ray model. DSA images of live rats were taken at two representative tube potentials for the W and Mo sources. Results show that for small animal DSA, the Mo source provides better contrast. However, with digital detectors, SdNR2 is the more relevant figure of merit. The W source operated at kVps >60 achieved a higher SdNR2. The highest SdNR2 was obtained at voltages above 90 kVp. However, operation at the higher potential results in significantly greater dose and tube load and reduced contrast quantization. A reasonable tradeoff can be achieved at tube potentials at the beginning of the performance plateau, around 70 kVp, where the relative gain in SdNR2 is the greatest.

Algorithms↗

Recent advances in chest radiography.

There have been many remarkable advances in conventional thoracic imaging over the past decade. Perhaps the most remarkable is the rapid conversion from film-based to digital radiographic systems. Computed radiography is now the preferred imaging modality for bedside chest imaging. Direct radiography is rapidly replacing film-based chest units for in-department posteroanterior and lateral examinations. An exciting aspect of the conversion to digital radiography is the ability to enhance the diagnostic capabilities and influence of chest radiography. Opportunities for direct computer-aided detection of various lesions may enhance the radiologist's accuracy and improve efficiency. Newer techniques such as dual-energy and temporal subtraction radiography show promise for improved detection of subtle and often obscured or overlooked lung lesions. Digital tomosynthesis is a particularly promising technique that allows reconstruction of multisection images from a short acquisition at very low patient dose. Preliminary data suggest that, compared with conventional radiography, tomosynthesis may also improve detection of subtle lung lesions. The ultimate influence of these new technologies will, of course, depend on the outcome of rigorous scientific validation.

Data Display↗

Simulation of liver lesions for pediatric CT.

PURPOSE: To develop and validate a technique based on characteristics of real lesions for simulating realistic small liver lesions on pediatric computed tomographic (CT) images. MATERIALS AND METHODS: The institutional review board provided exempt status for this study, determined that it was not subject to HIPAA compliance, and did not require informed consent. Patient identification information was removed from clinical images from contrast material-enhanced multi-detector row CT examinations performed in 10 children. Patients were infants or children up to 18 years old. Information about sex was not available. Children had one or more liver lesions of 2-6 mm in maximum transverse diameter. Images with more than one lesion were rendered multiple times, and each time, all but one of the lesions were digitally removed in sequence. This process provided images (n = 19) with a single real lesion. For consistency, the same image backgrounds (images with all real lesions removed) were used to create an identical number of images (n = 19), each with a single simulated lesion. Subsequently, three radiologists independently assessed images of real and simulated lesions that were presented in random order with a score on a continuous scale of 0 (definitely simulated) to 100 (definitely real). Mixed-model analysis of variance was used to test the null hypothesis that the difference in population mean scores between the two lesion types was zero. RESULTS: The observer study did not reveal a significant difference in the ability of any radiologist to discriminate between real and simulated lesions (P > .31). The differences in mean scores for discrimination between real and simulated lesions for the three observers were -6, 9, and -7, respectively. The estimated overall difference was -1. CONCLUSION: Mathematic simulation of liver lesions is a feasible technique for creating realistic lesions for image quality or dose reduction studies in pediatric CT.

Adolescent↗

Comparison of edge analysis techniques for the determination of the MTF of digital radiographic systems.

The modulation transfer function (MTF) is well established as a metric to characterize the resolution performance of a digital radiographic system. Implemented by various laboratories, the edge technique is currently the most widespread approach to measure the MTF. However, there can be differences in the results attributed to differences in the analysis technique employed. The objective of this study was to determine whether comparable results can be obtained from different algorithms processing identical images representative of those of current digital radiographic systems. Five laboratories participated in a round-robin evaluation of six different algorithms including one prescribed in the International Electrotechnical Commission (IEC) 62220-1 standard. The algorithms were applied to two synthetic and 12 real edge images from different digital radiographic systems including CR, and direct- and indirect-conversion detector systems. The results were analysed in terms of variability as well as accuracy of the resulting presampled MTFs. The results indicated that differences between the individual MTFs and the mean MTF were largely below 0.02. In the case of the two simulated edge images, all algorithms yielded similar results within 0.01 of the expected true MTF. The findings indicated that all algorithms tested in this round-robin evaluation, including the IEC-prescribed algorithm, were suitable for accurate MTF determination from edge images, provided the images are not excessively noisy. The agreement of the MTF results was judged sufficient for the measurement of the MTF necessary for the determination of the DQE.

Algorithms↗

Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems.

PURPOSE: To evaluate the scatter, dose, and effective detective quantum efficiency (DQE) performance of a slot-scan digital chest radiography system compared with that of a full-field digital radiography system. MATERIALS AND METHODS: Scatter fraction of a slot-scan system was measured for an anthropomorphic and a geometric phantom by using a posterior beam-stop technique at 117 and 140 kVp. Measurements were repeated with a full-field digital radiography system with and without a 13:1 antiscatter grid at 120 and 140 kVp. For both systems, the effective dose was measured on posteroanterior and lateral views for standard clinical techniques by using dosimeters embedded in a female phantom. The effective DQEs of the two systems were assessed by taking into account the scatter performance and the DQE of each system. The statistical significance of all the comparative differences was ascertained by means of t test analysis. RESULTS: The slot-scan system and the full-field system with grid yielded scatter fractions of 0.13-0.14 and 0.42-0.48 in the lungs and 0.30-0.43 and 0.69-0.78 in the mediastinum, respectively. The sum of the effective doses for posteroanterior and lateral views for the slot-scan system (0.057 mSv +/- 0.003 [+/- standard deviation]) was 34% lower than that for the full-field system (0.086 mSv +/- 0.001, P < .05) at their respective clinical peak voltages (140 and 120 kVp, respectively). The effective DQE of the slot-scan system was equivalent to that of the full-field system in the lung region but was 37% higher in the dense regions (P < .05). CONCLUSION: The slot-scan design leads to marked scatter reduction compared with the more conventional full-field geometries with a grid. The improved scatter performance of a slot-scan geometry can effectively compensate for low DQE and lead to improved image quality.

Phantoms, Imaging↗

A framework for optimising the radiographic technique in digital X-ray imaging.

The transition to digital radiology has provided new opportunities for improved image quality, made possible by the superior detective quantum efficiency and post-processing capabilities of new imaging systems, and advanced imaging applications, made possible by rapid digital image acquisition. However, this transition has taken place largely without optimising the radiographic technique used to acquire the images. This paper proposes a framework for optimising the acquisition of digital X-ray images. The proposed approach is based on the signal and noise characteristics of the digital images and the applied exposure. Signal is defined, based on the clinical task involved in an imaging application, as the difference between the detector signal with and without a target present against a representative background. Noise is determined from the noise properties of uniformly acquired images of the background, taking into consideration the absorption properties of the detector. Incident exposure is estimated or otherwise measured free in air, and converted to dose. The main figure of merit (FOM) for optimisation is defined as the signal-difference-to-noise ratio (SdNR) squared per unit exposure or (more preferably) dose. This paper highlights three specific technique optimisation studies that used this approach to optimise the radiographic technique for digital chest and breast applications. In the first study, which was focused on chest radiography with a CsI flat-panel detector, a range of kV(p) (50-150) and filtration (Z = 13-82) were examined in terms of their associated FOM as well as soft tissue to bone contrast, a factor of importance in digital chest radiography. The results indicated that additive Cu filtration can improve image quality. A second study in digital mammography using a selenium direct flat-panel detector indicated improved SdNR per unit exposure with the use of a tungsten target and a rhodium filter than conventional molybdenum target/molybdenum filter techniques. Finally, a third study focusing on cone-beam computed tomography of the breast using a CsI flat-panel detector indicated that high Z filtration of a tungsten target X-ray beam can notably improve the signal and noise characteristics of the image. The general findings highlight the fact that the techniques that are conventionally assumed to be optimum may need to be revisited for digital radiography.

Bone and Bones↗

Physical characterization of a prototype selenium-based full field digital mammography detector.

The purpose of this study was to measure experimentally the physical performance of a prototype mammographic imager based on a direct detection, flat-panel array design employing an amorphous selenium converter with 70 microm pixels. The system was characterized for two different anode types, a molybdenum target with molybdenum filtration (Mo/Mo) and a tungsten target with rhodium filtration (W/Rh), at two different energies, 28 and 35 kVp, with approximately 2 mm added aluminum filtration. To measure the resolution, the presampled modulation transfer function (MTF) was measured using an edge method. The normalized noise power spectrum (NNPS) was measured by two-dimensional Fourier analysis of uniformly exposed mammograms. The detective quantum efficiencies (DQEs) were computed from the MTFs, the NNPSs, and theoretical ideal signal to noise ratios. The MTF was found to be close to its ideal limit and reached 0.2 at 11.8 mm(-1) and 0.1 at 14.1 mm(-1) for images acquired at an RQA-M2 technique (Mo/Mo anode, 28 kVp, 2 mm Al). Using a tungsten technique (MW2; W/Rh anode, 28 kVp, 2 mm Al), the MTF went to 0.2 at 11.2 mm(-1) and to 0.1 at 13.3 mm(-1). The DQE reached a maximum value of 54% at 1.35 mm(-1) for the RQA-M2 technique at 1.6 microC/kg and achieved a peak value of 64% at 1.75 mm(-1) for the tungsten technique (MW2) at 1.9 microC/kg. Nevertheless, the DQE showed strong exposure and frequency dependencies. The results indicated that the detector offered high MTFs and DQEs, but structured noise effects may require improved calibration before clinical implementation.

Equipment Design↗

Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report.

Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (Lamb) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/ secondary displays are maximum luminance of greater than 170/100 cd/m2, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u',v' color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.

Computer Graphics↗

Measurement of the detective quantum efficiency in digital detectors consistent with the IEC 62220-1 standard: practical considerations regarding the choice of filter material.

As part of a larger evaluation we attempted to measure the detective quantum efficiency (DQE) of an amorphous silicon flat-panel detector using the method described in the International Electrotechnical Commission standard 62220-1 published in October 2003. To achieve the radiographic beam conditions specified in the standard, we purchased scientific-grade ultrahigh purity aluminum (99.999% purity, type-11999 alloy) filters in thicknesses ranging from 0.1 through 10.0 mm from a well-known, specialty metals supplier. Qualitative evaluation of flat field images acquired at 71 kV (RQA5 beam quality) with 21 mm of ultrahigh purity aluminum filtration demonstrated a low frequency mottle that was reproducible and was not observed when the measurement was repeated at 74 kV (RQA5 beam quality) with 21 mm of lower-purity aluminum (99.0% purity, type-1100 alloy) filtration. This finding was ultimately attributed to the larger grain size (approximately 1-2 mm) of high purity aluminum metal, which is a well-known characteristic, particularly in thicknesses greater than 1 mm. The impact of this low frequency mottle is to significantly overestimate the noise power spectrum (NPS) at spatial frequencies < or = 0.2 mm(-1), which in turn would cause an underestimation of the DQE in this range. A subsequent evaluation of ultrahigh purity aluminum, purchased from a second source, suggests, that reduced grain size can be achieved by the process of annealing. Images acquired with this sample demonstrated vertical striated nonuniformities that are attributed to the manufacturing method and which do not appear to appreciably impact the NPS at spatial frequencies > or = 0.5 mm(-1), but do result in an asymmetry in the x- and y-NPS at spatial frequencies < or = 0.2 mm(-1). Our observations of markedly visible nonuniformities in images acquired with high purity aluminum filtration suggest that the uniformity of filter materials should be carefully evaluated and taken into consideration when measuring the DQE.

Equipment Failure Analysis↗