PubMed Health⌕ Search

Biomedical subjects

Elan Bomsztyk

Publications and source records attributed to Elan Bomsztyk.

4 recordsLinked to original sources

Effect of blood vessels on measurement of nodule volume in a chest phantom.

PURPOSE: To identify, by using a chest phantom, whether vessels that contact lung nodules measuring less than 5 mm in diameter will affect nodule volume assessment. MATERIALS AND METHODS: Forty synthetic nodules (20 with ground-glass attenuation and 20 with solid attenuation) that measured less than 5 mm in diameter were placed into a chest phantom either adjacent to (n = 30) or isolated from (n = 10) synthetic vessels. Nodules were imaged by using low-dose (20 mAs) and diagnostic (120 mAs) multi-detector row computed tomography (CT). Nodules that were known to lie in direct contact with vessels were confirmed by visual inspection. Nontargeted 1.25 x 1.00-mm sections were analyzed with a three-dimensional computer-assisted method for measuring nodule volume. A mixed-model analysis of variance was used to examine the influence of several factors (eg, the presence of adjacent vessels; tube current-time product; and nodule attenuation, diameter, and location) on measurement error. RESULTS: The mean absolute error (MAE) for all nodules adjacent to vessels was 2.3 mm(3), which was higher than the MAE for isolated nodules (1.9 mm(3)) (P < .001). This difference proved significant only for diagnostic CT (2.2 mm(3) for nodules adjacent to vessels vs 1.3 mm(3) for nodules isolated from vessels) (P < .05). A larger MAE was noted for nodules with ground-glass attenuation (2.3 mm(3)) versus those with solid attenuation (2.0 mm(3)), for increasing nodule volume (1.66 mm(3) for nodules smaller than 20 mm(3) vs 2.83 mm(3) for nodules larger than 40 mm(3)), and for posterior nodule location (P < .05). CONCLUSION: The presence of a vessel led to a small yet significant increase in volume error on diagnostic-quality images. This represents less than one-third of the overall error, even for nodules larger than 40 mm(3) or approximately 4 mm in diameter. This increase, however, may be more important for smaller nodules with errors of less than 3 mm(3).

Diagnostic Errors↗

Appendicitis in children: low-dose CT with a phantom-based simulation technique--initial observations.

PURPOSE: To retrospectively determine the accuracy of low-dose (20-mAs) computed tomography (CT) in the diagnosis of acute appendicitis in children by using a technique that enables the simulation of human CT scans acquired at a lower tube current given the image acquired at a standard dose. MATERIALS AND METHODS: Institutional review board approval was obtained, informed consent was not required, and the study was HIPAA compliant. The authors reviewed 100 standard-dose pediatric abdominal-pelvic CT scans (50 positive and 50 negative scans) obtained in 100 patients and corresponding simulated low-dose (20-mAs) scans. The standard-dose scans were obtained for evaluation in patients suspected of having appendicitis. Scans were reviewed in randomized order by four experienced pediatric radiologists. The patients with positive findings included 21 girls (mean age, 9.2 years) and 29 boys (mean age, 8.4 years). The patients with negative findings included 28 girls (mean age, 9.2 years) and 22 boys (mean age, 8.4 years). Simulation was achieved by adding noise patterns from repeated 20-mAs scans of a pediatric pelvis phantom to the original scans obtained with a standard tube current. Observers recorded their confidence in the diagnosis of appendicitis by using a six-point scale. Dose-related changes were analyzed with generalized estimating equations and the nonparametric sign test. RESULTS: There was a statistically significant (P < .001, sign test) decrease in both sensitivity and accuracy with a lower tube current, from 91.5% with the original tube current to 77% with the lower tube current. A low dose was the only statistically significant (P < .001) risk factor for a false-negative result. The specificity was unchanged at 94% for both the images obtained with the original tube current and the simulated low-dose images. The overall accuracy decreased from 92% with the original dose to 86% with the low dose. CONCLUSION: Preliminary findings indicate that it is feasible to optimize the CT dose used to evaluate appendicitis in children by using phantom-based computer simulations.

Adolescent↗

Effect of CT image compression on computer-assisted lung nodule volume measurement.

PURPOSE: To evaluate the effect of two-dimensional wavelet-based computed tomographic (CT) image compression according to the Joint Photographic Experts Group (JPEG) 2000 standard on computer-assisted assessment of nodule volume. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the research board at the authors' institution; patients' informed consent was not required. Fifty-one nodules in 23 patients (seven men, 16 women; mean age, 59 years; age range, 39-75 years) were selected on low-dose CT scans that were compressed to levels of 10:1, 20:1, 30:1, and 40:1 by using a two-dimensional JPEG 2000 wavelet-based image compression method. Nodules were classified according to size (< or = 5 mm or > 5 mm in diameter), location (central, peripheral, or abutting pleura or fissures), and attenuation (solid, calcified, or subsolid). Regions of interest were placed on the original images and transposed onto compressed images. Nodule volumes on original (noncompressed) and compressed images were measured by using a computer-assisted method. A mixed-model analysis of variance was conducted for statistical evaluation. RESULTS: Nodule volumes averaged 388.1 mm3 (range, 34-3474 mm3). There were three calcified, 33 solid noncalcified, and 15 subsolid nodules (13 with ground-glass attenuation). Average volume decreased with increasing compression level, to 383 mm3 (10:1), 370 mm3 (20:1), 360 mm3 (30:1), and 354 mm3 (40:1). No significant difference was identified between measurements obtained on original images and those compressed to a level of 10:1. Significant differences were noted, however, between original images and those compressed to a level of 20:1 or greater (P < .05). Compression level significantly interacted with nodule size, location, and attenuation (P < .001). The effect of compression was greater for nodules with ground-glass attenuation than for those with higher attenuation values. The difference in mean volumes between original images and those compressed to a level of 20:1 was 34.9 mm3 for nodules with ground-glass attenuation, compared with 8.3 mm3 for higher-attenuation nodules, a 4.2-fold difference. CONCLUSION: Nodule volumes measured on images compressed to a level of 20:1 differed significantly from those measured on noncompressed images, especially for nodules with ground-glass attenuation. This difference could affect the assessment of nodule change in size as measured with computer-assisted methods.

Adult↗

Dilated perivascular spaces: hallmarks of mild traumatic brain injury.

BACKGROUND AND PURPOSE: Recent animal and human studies have shown an increased frequency of enlarged, high-convexity Virchow-Robin spaces (VRS) in several neurologic diseases, suggesting their role as neuroradiologic markers of inflammatory changes. The aim of this study was to determine the prevalence of high-convexity dilated VRS in mild traumatic brain injury (TBI). METHODS: T2-weighted, T1-weighted, fluid-attenuated inversion recovery, and T2*-weighted gradient-echo brain MR images were acquired in 24 patients with TBI (10 women, 14 men; mean age, 33.6; range, 18.1-50.8 years) and 17 age- and sex-matched healthy control subjects (nine women, eight men; mean age, 32.8; range, 18.4-47.8 years). The mean interval after TBI was 3.6 days (range, 1-9 days) in 15 patients and 3.7 years (range, 0.6-13.4 years) in nine patients. Axial T2-weighted images were used to identify dilated VRS and to measure CSF volume; T1-weighted images were used to measure brain volume. Dilated VRS were identified as punctuate areas with CSF-like signal intensity in the high-convexity white matter. RESULTS: Mean (+/- standard deviation) number of VRS was significantly higher in patients (7.1 +/- 4.6) than in controls (3.0 +/- 3.0, P = 0.002) [corrected] In controls, VRS were associated with age (R = 0.69, P < .001) whereas in patients, they neither correlated with brain and CSF volumes nor with age and the elapsed time from injury. CONCLUSION: Our results suggest that the increased number of dilated VRS is a radiologic marker of mild head injury that is readily detectable on T2-weighted images. Because their number does not vary with time from injury, VRS probably reflect early and permanent brain changes.

Adolescent↗