Empirical and theoretical dosimetry in support of whole body radio frequency (RF) exposure in seated human volunteers at 220 MHz.

This study reports the dosimetry performed to support an experiment that measured physiological responses of seated volunteer human subjects exposed to 220 MHz fields. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A vertical half-wave dipole with a 90 degrees reflector was used to optimize the field at the subject's location. The vertically polarized E field was incident on the dorsal side of the phantoms and human volunteers. The dosimetry plan required measurement of stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. A NBS (National Bureau of Standards, now NIST, National Institute of Standards and Technology, Boulder, CO) 10 cm loop antenna was positioned 150 cm to the right, 100 cm above and 60 cm behind the subject (toward the transmitting antenna) and was read prior to each subject's exposure and at 5 min intervals during all RF exposures. Transmitter stability was determined by measuring plate voltage, plate current, screen voltage and grid voltage for the driver and final amplifiers before and at 5 min intervals throughout the RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry to precisely control exposure levels for studies of the physiological consequences of human volunteer exposures to 220 MHz.

Absorption↗

Thermophysiological responses of human volunteers to whole body RF exposure at 220 MHz.

Since 1994, our research has demonstrated how thermophysiological responses are mobilized in human volunteers exposed to three radio frequencies, 100, 450, and 2450 MHz. A significant gap in this frequency range is now filled by the present study, conducted at 220 MHz. Thermoregulatory responses of heat loss and heat production were measured in six adult volunteers (five males, one female, aged 24-63 years) during 45 min whole body dorsal exposures to 220 MHz radio frequency (RF) energy. Three power densities (PD = 9, 12, and 15 mW/cm(2) [1 mW/cm(2) = 10 W/m(2)], whole body average normalized specific absorption rate [SAR] = 0.045 [W/kg]/[mW/cm(2)] = 0.0045 [W/kg]/[W/m(2)]) were tested at each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C) plus T(a) controls (no RF). Measured responses included esophageal (T(esoph)) and seven skin temperatures (T(sk)), metabolic rate (M), local sweat rate, and local skin blood flow (SkBF). Derived measures included heart rate (HR), respiration rate, and total evaporative water loss (EWL). Finite difference-time domain (FDTD) modeling of a seated 70 kg human exposed to 220 MHz predicted six localized "hot spots" at which local temperatures were also measured. No changes in M occurred under any test condition, while T(esoph) showed small changes (< or =0.35 degrees C) but never exceeded 37.3 degrees C. As with similar exposures at 100 MHz, local T(sk) changed little and modest increases in SkBF were recorded. At 220 MHz, vigorous sweating occurred at PD = 12 and 15 mW/cm(2), with sweating levels higher than those observed for equivalent PD at 100 MHz. Predicted "hot spots" were confirmed by local temperature measurements. The FDTD model showed the local SAR in deep neural tissues that harbor temperature-sensitive neurons (e.g., brainstem, spinal cord) to be greater at 220 than at 100 MHz. Human exposure at both 220 and 100 MHz results in far less skin heating than occurs during exposure at 450 MHz. However, the exposed subjects thermoregulate efficiently because of increased heat loss responses, particularly sweating. It is clear that these responses are controlled by neural signals from thermosensors deep in the brainstem and spinal cord, rather than those in the skin.

Adult↗

Modeling thermal responses in human subjects following extended exposure to radiofrequency energy.

BACKGROUND: This study examines the use of a simple thermoregulatory model for the human body exposed to extended (45 minute) exposures to radiofrequency/microwave (RF/MW) energy at different frequencies (100, 450, 2450 MHz) and under different environmental conditions. The exposure levels were comparable to or above present limits for human exposure to RF energy. METHODS: We adapted a compartmental model for the human thermoregulatory system developed by Hardy and Stolwijk, adding power to the torso skin, fat, and muscle compartments to simulate exposure to RF energy. The model uses values for parameters for "standard man" that were originally determined by Hardy and Stolwijk, with no additional adjustment. The model predicts changes in core and skin temperatures, sweat rate, and changes in skin blood flow as a result of RF energy exposure. RESULTS: The model yielded remarkably good quantitative agreement between predicted and measured changes in skin and core temperatures, and qualitative agreement between predicted and measured changes in skin blood flow. The model considerably underpredicted the measured sweat rates. CONCLUSIONS: The model, with previously determined parameter values, was successful in predicting major aspects of human thermoregulatory response to RF energy exposure over a wide frequency range, and at different environmental temperatures. The model was most successful in predicting changes in skin temperature, and it provides insights into the mechanisms by which the heat added to body by RF energy is dissipated to the environment. Several factors are discussed that may have contributed to the failure to account properly for sweat rate. Some features of the data, in particular heating of the legs and ankles during exposure at 100 MHz, would require a more complex model than that considered here.

Adult↗

Radial arm maze performance of rats following repeated low level microwave radiation exposure.

We examined the possibility of changes in "working" memory of rats following whole body exposure to microwave (MW) radiation. During each of 10 days, we exposed rats within circularly polarized waveguides for 45 min to 2450 MHz fields at whole body SARs of 0.6 W/kg (2 micros pulses, 500 pps), followed by testing in a 12 arm, radial arm maze (RAM). Rats received a preexposure injection of one of three psychoactive compounds or saline, to determine whether a compound would interact with MW exposure to affect performance in the maze. Error rate, i.e., reentry into arms already visited, and time to criterion data for 10 consecutive days of testing were analyzed by a three way analysis of variance (ANOVA) using main effects of "exposure" and "drug" and a repeated factor of "test day." Our alpha limit for significance was P <.05. Analyzes of error rates revealed no significant exposure effect, no significant drug effect and no significant interaction between the two main factors. There was a significant difference in test days, as expected, with repeated test-trial days, which indicates that learning was accomplished. There was no significant interaction of test day and the other two factors. The results of our analyzes of time to criterion data included no significant exposure effect, a significant drug effect, a significant test day effect, and a significant interaction between drug and test day factors. Post hoc analyzes of the drug factor revealed that rats treated with either physostigmine or nalrexone hydrochloride, took significantly longer to complete the maze task than rats pretreated with saline or with naloxone methodide. We conclude that there is no evidence from the current study that exposure to of MW radiation under parameters examined caused decrements in the ability of rats to learn the spatial memory task.

Animals↗

Thermophysiological consequences of whole body resonant RF exposure (100 MHz) in human volunteers.

Thermophysiological responses of heat production and heat loss were measured in seven adult volunteers (six males and one female, aged 31-74 years) during 45 min dorsal exposures of the whole body to 100 MHz continuous wave (CW) radio frequency (RF) energy. Three power densities (PD) (average PD = 4, 6, and 8 mW/cm(2); whole body specific absorption rate [SAR] = 0.068 [W/kg]/[mW/cm(2)]) were tested in each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C), as well as in T(a) controls (no RF). A standardized protocol (30 min baseline, 45 min RF or sham exposure, 10 min baseline) was used. Measured responses included esophageal and seven skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow. No changes in metabolic heat production occurred under any test condition. Unlike published results of similar exposures at 450 and 2450 MHz, local skin temperatures, even those on the back that were irradiated directly, changed little or not at all during 100 MHz exposures. The sole exception was the temperature of the ankle skin, which increased by 3-4 degrees C in some subjects at PD = 8 mW/cm(2). During the 45 min RF exposure, esophageal temperature showed modest changes (range = -0.15 to 0.13 degrees C) and never exceeded 37.2 degrees C. Thermoregulation was principally controlled by appropriate increases in evaporative heat loss (sweating) and, to a lesser extent, by changes in skin blood flow. Because of the deep penetration of RF energy at this frequency, effectively bypassing the skin, these changes must have been stimulated by thermal receptors deep in the body rather than those located in the skin.

Adult↗

Empirical and theoretical dosimetry in support of whole body resonant RF exposure (100 MHz) in human volunteers.

This study reports the dosimetry performed to support an experiment that measured physiological responses of volunteer human subjects exposed to the resonant frequency for a seated human adult at 100 MHz. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A half wave dipole with a 90 degrees reflector was used to optimize the field at the subject location. The dosimetry plan required measurement of transmitter harmonics, stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. On each exposure test day, a measurement was taken at 225 cm on the beam centerline with a NBS E field probe to assure consistently precise exposures. A NBS 10 cm loop antenna was positioned 150 cm to the right, 100 cm above, and 60 cm behind the subject and was read at 5 min intervals during all RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry for work on physiological consequences of human volunteer exposures to 100 MHz.

Adult↗

Thermoregulatory responses to RF energy absorption.

This white paper combines a tutorial on the fundamentals of thermoregulation with a review of the current literature concerned with physiological thermoregulatory responses of humans and laboratory animals in the presence of radio frequency (RF) and microwave fields. The ultimate goal of research involving whole body RF exposure of intact organisms is the prediction of effects of such exposure on human beings. Most of the published research on physiological thermoregulation has been conducted on laboratory animals, with a heavy emphasis on laboratory rodents. Because their physiological heat loss mechanisms are limited, these small animals are very poor models for human beings. Basic information about the thermoregulatory capabilities of animal models relative to human capability is essential for the appropriate evaluation and extrapolation of animal data to humans. In general, reliance on data collected on humans and nonhuman primates, however fragmentary, yields a more accurate understanding of how RF fields interact with humans. Such data are featured in this review, including data from both clinic and laboratory. Featured topics include thermal sensation, human RF overexposures, exposures attending magnetic resonance imaging (MRI), predictions based on simulation models, and laboratory studies of human volunteers. Supporting data from animal studies include the thermoregulatory profile, response thresholds, physiological responses of heat production and heat loss, intense or prolonged exposure, RF effects on early development, circadian variation, and additive drug-microwave interactions. The conclusion is inescapable that humans demonstrate far superior thermoregulatory ability over other tested organisms during RF exposure at, or even above current human exposure guidelines.

Animals↗

Behavioral and cognitive effects of microwave exposure.

This paper presents an overview of the recent behavioral literature concerning microwave exposure and discusses behavioral effects that have supported past exposure standards. Other effects, which are based on lower levels of exposure, are discussed as well, relative to setting exposure standards. The paper begins with a brief discussion of the ways in which behavioral end points are investigated in the laboratory, together with some of the methodological considerations pertinent to such studies when radio frequency (RF) exposure is involved. It has been pointed out by several sources that exposure to RF radiation can lead to changes in the behavior of humans and laboratory animals that can range from the perceptions of warmth and sound to lethal body temperatures. Behavior of laboratory animals can be perturbed and, under certain other conditions, animals will escape and subsequently avoid RF fields; but they will also work to obtain a burst of RF energy when they are cold. Reports of change of cognitive function (memory and learning) in humans and laboratory animals are in the scientific literature. Mostly, these are thermally mediated effects, but other low level effects are not so easily explained by thermal mechanisms. The phenomenon of behavioral disruption by microwave exposure, an operationally defined rate decrease (or rate increase), has served as the basis for human exposure guidelines since the early 1980s and still appears to be a very sensitive RF bioeffect. Nearly all evidence relates this phenomenon to the generation of heat in the tissues and reinforces the conclusion that behavioral changes observed in RF exposed animals are thermally mediated. Such behavioral alteration has been demonstrated in a variety of animal species and under several different conditions of RF exposure. Thermally based effects can clearly be hazardous to the organism and continue to be the best predictor of hazard for homosapiens. Nevertheless, similar research with man has not been conducted. Although some studies on human perception of RF exist, these should be expanded to include a variety of RF parameters.

Animals↗

Microwave effects on the nervous system.

Studies have evaluated the electroencephalography (EEG) of humans and laboratory animals during and after Radiofrequency (RF) exposures. Effects of RF exposure on the blood-brain barrier (BBB) have been generally accepted for exposures that are thermalizing. Low level exposures that report alterations of the BBB remain controversial. Exposure to high levels of RF energy can damage the structure and function of the nervous system. Much research has focused on the neurochemistry of the brain and the reported effects of RF exposure. Research with isolated brain tissue has provided new results that do not seem to rely on thermal mechanisms. Studies of individuals who are reported to be sensitive to electric and magnetic fields are discussed. In this review of the literature, it is difficult to draw conclusions concerning hazards to human health. The many exposure parameters such as frequency, orientation, modulation, power density, and duration of exposure make direct comparison of many experiments difficult. At high exposure power densities, thermal effects are prevalent and can lead to adverse consequences. At lower levels of exposure biological effects may still occur but thermal mechanisms are not ruled out. It is concluded that the diverse methods and experimental designs as well as lack of replication of many seemingly important studies prevents formation of definite conclusions concerning hazardous nervous system health effects from RF exposure. The only firm conclusion that may be drawn is the potential for hazardous thermal consequences of high power RF exposure.

Animals↗