Eli Grushka

Publications and source records attributed to Eli Grushka.

3 recordsLinked to original sources

Organically modified silica sol-mediated capillary electrophoresis.

We describe in this paper the use of ormosil (organically modified silica) sols as additives to the run buffer for selectivity manipulations between solutes in capillary electrophoresis. CE systems that contain sol additives in the run buffer can be thought of as pseudocapillary electrochromatography. Three sols based on different types of silanes were studied. Methyltrimethoxysilane (MTMOS)-based sol was found to improve selectivities between various aromatic acids. Aminopropyltrimethoxysilane (APS) sol interacts differently with structural isomers of aromatic acids than does MTMOS. At low pH with APS sol in the run buffer, neutral solutes can be separated, as well. The separation of the neutral solutes seems to be facilitated by the formation of hydrogen bonds between the solutes and the APS sol. APS and N-[3-(trimethoxysilyl)propyl]-ethylenediamine (EDAS) affect the separation of the same compounds differently, thus indicating that even small changes of the functional groups of the sol have pronounced effect on the interactions between the sols and the solutes.

Journal Article↗

Temperature-dependent refractive index issues using a UV-visible detector in high-performance liquid chromatography.

While studying the properties of some potential, UV-detection compatible, mobile phase modifiers for reversed-phase liquid chromatography (RPLC) we encountered serious detector baseline problems. The most severe problem was a periodic saw-tooth-shaped drift. This drift was most noticeable when using water-THF and water-dioxolane mobile phases. We demonstrate that the baseline problems are related to temperature fluctuation in a water bath used to maintain a constant column temperature. The temperature fluctuations change the refractive index (RI) of the mobile phase, which in turn affects the amount of light reaching the detector. Our results show that the magnitude of the baseline drift is related to the RI value of the mobile phases. The baseline problems can be alleviated using a different temperature controller whose feedback mechanism assures smoother operation. Since there is no single and complete source of information in the literature concerning the RI values of typical mobile phases in RPLC, we decided to measure them as a function of the % modifier (between 0 and 100%) and the temperature (between 25 degrees C and 50 degrees C). Knowing the RI values allows us to calculate the excess volume of a binary liquid system.

Chromatography, High Pressure Liquid↗