PubMed Health⌕ Search

Biomedical subjects

Elisa Birnbaum

Publications and source records attributed to Elisa Birnbaum.

4 recordsLinked to original sources

Safety and effectiveness of temperature-controlled radio-frequency energy delivery to the anal canal (Secca procedure) for the treatment of fecal incontinence.

PURPOSE: This multicenter study evaluated the safety and efficacy of radio-frequency energy delivery to the anal canal for the treatment of fecal incontinence. METHODS: Fifty patients at five centers were enrolled. All reported fecal incontinence at least once per week for three months, and medical and/or surgical management failed to help their symptoms. At baseline and at six months, patients completed questionnaires (Cleveland Clinic Florida Fecal Incontinence score (0-20), fecal incontinence-related quality of life, Short Form-36, and visual analog scale) and underwent anorectal manometry, endoanal ultrasound, and pudendal nerve terminal motor latency testing. On an outpatient basis using local anesthesia, radio-frequency energy was delivered via an anoscopic device with multiple needle electrodes (Secca system) to create thermal lesions deep to the mucosa of the anal canal. RESULTS: Forty-three females and seven males (aged 61.1 +/- 13.4 (mean +/- standard deviation); range, 30-80 years) were treated. Mean duration of fecal incontinence was 14.9 years. Treatment time was 37 +/- 9 minutes. At six months, the mean Cleveland Clinic Florida Fecal Incontinence score improved from 14.5 to 11.1 (P < 0.0001). All parameters in the Fecal Incontinence Quality of Life scales were improved (lifestyle (from 2.5-3.1; P < 0.0001); coping (from 1.9-2.4; P < 0.0001), depression (from 2.8-3.3; P = 0.0004); embarrassment (from 1.9-2.5; P < 0.0001)). Responders, as assessed by a systematic referenced analog scale, reported a median 70 percent resolution of symptoms. The mean Short Form-36 social function improved from 64.3 to 76 (P = 0.003). There were no changes in endoanal ultrasound or pudendal nerve terminal motor latency assessment, or in anal manometry. Complications included mucosal ulceration (one superficial, one with underlying muscle injury) and delayed bleeding (n = 1). CONCLUSION: This multicenter trial demonstrates that radio-frequency energy can be safely delivered to the lower rectum and anal canal. The Secca procedure significantly improved the Cleveland Clinic Florida Fecal Incontinence score and the overall quality of life for most patients having undergone the procedure.

Adult↗

The safety and efficacy of the artificial bowel sphincter for fecal incontinence: results from a multicenter cohort study.

PURPOSE: The aim of this trial was to evaluate the safety, efficacy, and impact on quality of life of the Acticon trade mark artificial bowel sphincter for fecal incontinence. METHODS: A multicenter, prospective, nonrandomized clinical trial was conducted under a common protocol. Patients were evaluated with anal physiology, endoanal ultrasonography, a fecal incontinence scoring system, fecal incontinence quality of life assessment, and overall health evaluation. Patients with a fecal incontinence score of 88 or greater (scale, 1-120) were considered candidates for the study. Implanted patients underwent identical reevaluation at 6 and 12 months postimplant. RESULTS: One hundred twelve of 115 patients (86 females) enrolled were implanted. Mean age was 49 (range, 18-81) years. A total of 384 device-related or potentially device-related adverse events were reported in 99 enrolled patients. Of these events, 246 required no intervention or only noninvasive intervention. Seventy-three revisional operations were required in 51 (46 percent) of the 112 implanted patients. Infection rate necessitating surgical revision was 25 percent. Forty-one patients (37 percent) have had their devices completely explanted, of which 7 have had successful reimplantations. In patients with a functioning neosphincter, improvement in quality of life and anal continence was documented. Mean matched fecal incontinence scores in 63 patients at 6 months follow-up was improved from 105 preimplant to 51 postimplant. In 55 patients at 12 months follow-up, mean matched fecal incontinence scores were 105 preimplant 48 postimplant. A successful outcome was achieved in 85 percent of patients with a functioning device. Intention to treat success rate was 53 percent. CONCLUSIONS: Although morbidity and the need for revisional surgery are high, the artificial bowel sphincter can improve anal incontinence and quality of life in patients with severe fecal incontinence.

Adult↗

Early results from a phase I/II radiation dose-escalation study with concurrent amifostine and infusional 5-fluorouracil chemotherapy for preoperative treatment of unresectable or locally recurrent rectal carcinoma.

To improve the resectability and long-term local control of locally advanced rectal cancer, we have initiated a radiation dose-escalation trial. It is hoped that the radioprotector amifostine will sufficiently reduce rectal morbidity (without also reducing tumor response) to permit increasing radiation doses. Only 6 patients have been treated at the first dose level (45 Gy with a 9-Gy boost and concurrent continuous infusion of 5-fluorouracil). During treatment, daily stool frequency improved or was stable. There was one case of transitory severe proctitis/enteritis. Four of the six patients achieved objective responses to preoperative treatment. These very early results suggest that the use of amifostine does not interfere with tumor response and that it may facilitate the delivery of higher boost doses to the rectum.

Adenocarcinoma↗