PubMed Health⌕ Search

Biomedical subjects

Elisabeth Csöregi

Publications and source records attributed to Elisabeth Csöregi.

9 recordsLinked to original sources

Simultaneous detection of L-glutamate and nitric oxide from adherently growing cells at known distance using disk shaped dual electrodes.

An ex vivo system for simultaneous detection of nitric oxide (NO) and L-glutamate using integrated dual 250 microm platinum disk electrodes modified individually with suitable sensing chemistries has been developed. One of the sensors was coated with an electrocatalytic layer of Ni tetrasulfonate phthalocyanine tetrasodium salt (Ni-TSPc) covered by second layer of Nafion, which stabilises on the one hand the primary oxidation product NO(+) and prevents interferences from negatively charged compounds such as NO(2)(-). For glutamate determination, the second electrode was modified with a crosslinked redox hydrogel consisting of Os complex modified poly(vinylimidazol), glutamate oxidase and peroxidase. A manual x-y-z micromanipulator on top of an inverted optical microscope was used to position the dual electrode sensor at a defined distance of 5 microm from a cell population under visual control. C6 glioma cells were stimulated simultaneously with bradykinin or VEGF to release NO while KCl was used to invoke glutamate release. For evaluation of the glutamate sensors, in some experiments HN10 cells were used. To investigate the sensitivity and reliability of the system, several drugs were applied to the cells, e.g. Ca(2+)-channel inhibitors for testing Ca(2+)-dependence of the release of NO and glutamate, rotenone for inducing oxidative stress and glutamate antagonists for analysing glutamate release. With these drugs the NO and glutamate release was modulated in a similar way then expected from previously described systems or even in-vivo measurements. We therefore conclude that our system is suitable to analyse stress-induced mechanisms in cell lines.

Animals↗

Palm tree peroxidase-based biosensor with unique characteristics for hydrogen peroxide monitoring.

Three amperometric enzyme electrodes have been constructed by adsorbing anionic royal palm tree peroxidase (RPTP), anionic sweet potato peroxidase (SPP), or cationic horseradish peroxidase (HRP-C) on spectroscopic graphite electrodes. The resulting H(2)O(2)-sensitive biosensors were characterized both in a flow injection system and in batch mode to evaluate their main bioelectrochemical parameters, such as pH dependency, I(max), K(M)(app), detection limit, linear range, operational and storage stability. The obtained results showed a distinctly different behavior for the plant peroxidase electrodes, demonstrating uniquely superior characteristics of the RPTP-based sensors. The broader linear range observed for the RPTP-based biosensor is explained by a high stability of this enzyme in presence of H(2)O(2). The higher storage and operational stability of RPTP-based biosensor as well as its capability to measure hydrogen peroxide under acidic conditions connect with an extremely high thermal and pH-stability of RPTP.

Arecaceae↗

Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate.

There is an increasing interest in new strategies for replacing animal tests in research. The use of cell cultures and integrated electrodes is seen as a promising alternative that could potentially solve this problem. In this work, we present a L-glutamate sensor based on a bienzyme redox hydrogel, capable of detecting the release of this excitatory neurotransmitter from adherently growing cells upon stimulation. The low working potential required for the operation of the sensor decreases the possibility of interference by easily oxidizable compounds always present in complex biological samples. A low detection limit of 0.5 microM L-glutamate, a response time of about 35 s, and a linear range of up to 60 microM are the main characteristics of the sensor. The system has been successfully employed to monitor the release of l-glutamate from HN10 and C6 cells upon stimulation with K(+)-ions. The developed integrated electrochemical platform will be used in future for drug screening and potentially for replacing animal models in neurological experiments.

Biological Assay↗

Visualization of micropatterned complex biosensor sensing chemistries by means of scanning electrochemical microscopy.

Redox hydrogel-based micropatterned complex biosensor architectures, used as sensing chemistries in amperometric ethanol or glucose biosensors, were deposited on gold, graphite or glass. Well-localized immobilization of active hydrogels with variable compositions was achieved by dispensing 100 pl droplets of cocktails containing alcohol or glucose dehydrogenase, redox polymer (PVI(13)dmeOs) and crosslinker (PEGDGE) while moving the target surface relative to the position of the nozzle of a piezo-actuated microdispenser. The resulting structures were microscopic patterns of enzyme-containing lines of a redox hydrogel with a line width of about 100 microm. Scanning electrochemical microscopy (SECM) in the amperometric feedback mode was used to visualize the immobilized enzyme microstructures and their localized biochemical activity was observed with high lateral resolution by detecting the enzymatically consumed substrate using K(4)[Fe(CN)(6)] as a free-diffusing electron-transfer mediator.

Biosensing Techniques↗

Biosensors for detection of mercury in contaminated soils.

Biosensors based on whole bacterial cells and on bacterial heavy metal binding protein were used to determine the mercury concentration in soil. The soil samples were collected in a vegetable garden accidentally contaminated with elemental mercury 25 years earlier. Bioavailable mercury was measured using different sensors: a protein-based biosensor, a whole bacterial cell based biosensor, and a plant sensor, i.e. morphological and biochemical responses in primary leaves and roots of bean seedlings grown in the mercury-contaminated soil. For comparison the total mercury concentration of the soil samples was determined by AAS. Whole bacterial cell and protein-based biosensors gave accurate responses proportional to the total amount of mercury in the soil samples. On the contrary, plant sensors were found to be less useful indicators of soil mercury contamination, as determined by plant biomass, mercury content of primary leaves and enzyme activities.

Biosensing Techniques↗

Cyclometalated ruthenium(II) complexes as efficient redox mediators in peroxidase catalysis.

Cyclometalated ruthenium(II) complexes, [Ru(II)(C~N)(N~N)(2)]PF(6) [HC~N=2-phenylpyridine (Hphpy) or 2-(4'-tolyl)pyridine; N~N=2,2'-bipyridine, 1,10-phenanthroline, or 4,4'-dimethyl-2,2'-bipyridine], are rapidly oxidized by H(2)O(2) catalyzed by plant peroxidases to the corresponding Ru(III) species. The commercial isoenzyme C of horseradish peroxidase (HRP-C) and two recently purified peroxidases from sweet potato (SPP) and royal palm tree (RPTP) have been used. The most favorable conditions for the oxidation have been evaluated by varying the pH, buffer, and H(2)O(2) concentrations and the apparent second-order rate constants ( k(app)) have been measured. All the complexes studied are oxidized by HRP-C at similar rates and the rate constants k(app) are identical to those known for the best substrates of HRP-C (10(6)-10(7) M(-1) s(-1)). Both cationic (HRP-C) and anionic (SPP and RPTP) peroxidases show similar catalytic efficiency in the oxidation of the Ru(II) complexes. The mediating capacity of the complexes has been evaluated using the SPP-catalyzed co-oxidation of [Ru(II)(phpy)(bpy)(2)]PF(6) and catechol as a poor peroxidase substrate as an example. The rate of enzyme-catalyzed oxidation of catechol increases more than 10000-fold in the presence of the ruthenium complex. A simple routine for calculating the rate constant k(c) for the oxidation of catechol by the Ru(III) complex generated enzymatically from [Ru(II)(phpy)(bpy)(2)](+) is proposed. It is based on the accepted mechanism of peroxidase catalysis and involves spectrophotometric measurements of the limiting Ru(II) concentration at different concentrations of catechol. The calculated k(c) value of 0.75 M(-1) s(-1) shows that the cyclometalated Ru(II) complexes are efficient mediators in peroxidase catalysis.

Animals↗

Bienzyme biosensors for glucose, ethanol and putrescine built on oxidase and sweet potato peroxidase.

Amperometric biosensors for glucose, ethanol, and biogenic amines (putrescine) were constructed using oxidase/peroxidase bienzyme systems. The H(2)O(2) produced by the oxidase in reaction with its substrate is converted into a measurable signal via a novel peroxidase purified from sweet potato peels. All developed biosensors are based on redox hydrogels formed of oxidases (glucose oxidase, alcohol oxidase, or amine oxidase) and the newly purified sweet potato peroxidase (SPP) cross-linked to a redox polymer. The developed electrodes were characterized (sensitivity, stability, and performances in organic medium) and compared with similarly built ones using the 'classical' horseradish peroxidase (HRP). The SPP-based electrodes displayed higher sensitivity and better detection limit for putrescine than those using HRP and were also shown to retain their activity in organic phase much better than the HPR based ones. The importance of attractive or repulsive electrostatic interactions between the peroxidases and oxidases (determined by their isoelectric points) were found to play an important role in the sensitivity of the obtained sensors.

Alcohol Oxidoreductases↗

Novel synthetic phytochelatin-based capacitive biosensor for heavy metal ion detection.

A novel capacitance biosensor based on synthetic phytochelatins for sensitive detection of heavy metals is described. Synthetic phytochelatin (Glu-Cys)(20)Gly (EC20) fused to the maltose binding domain protein was expressed in Escherichia coli and purified for construction of the biosensor. The new biosensor was able to detect Hg(2+), Cd(2+), Pb(2+), Cu(2+) and Zn(2+) ions in concentration range of 100 fM-10 mM, and the order of sensitivity was S(Zn)>S(Cu)>S(Hg)>>S(Cd) congruent with S(Pb). The biological sensing element of the sensor could be regenerated using EDTA and the storage stability of the biosensor was 15 days.

Biosensing Techniques↗