PubMed Health⌕ Search

Biomedical subjects

Eliza N Fung

Publications and source records attributed to Eliza N Fung.

4 recordsLinked to original sources

A computer program for automated data evaluation to support in vitro higher-throughput screening for drug metabolism and pharmacokinetics attributes.

With the advances in analytical techniques, higher-throughput screening for drug metabolism and pharmacokinetics (DMPK) attributes has become an integral part of drug discovery. However, as the number of compounds increases, the volume of data that needs to be processed and evaluated increases exponentially. As a result, a major challenge for the analytical chemist is how to quickly process the vast amount of data so as to keep up with the throughput of the screening assay. We have developed a customized computer program for automated evaluation of the liquid chromatography/tandem mass spectrometric (LC/MS/MS) data generated from the in vitro DMPK screening assays. This program performs automatic data processing and quality control. It identifies analytical anomalies, such as low internal standard intensity and poor reproducibility of replicates. All analytical anomalies for individual compounds are summarized into an 'E-Log' in a color-coded format for reviewing. With the use of this program and other supporting software, data processing and evaluation for up to 100 compounds are accomplished in several minutes.

Algorithms↗

Semi-automatic high-throughput determination of plasma protein binding using a 96-well plate filtrate assembly and fast liquid chromatography-tandem mass spectrometry.

A semi-automatic, high-throughput method has been developed to rapidly assess plasma protein binding of new chemical entities in drug discovery phase. New chemical entities are mixed with plasma and the unbound fractions are separated from the bound fraction by ultrafiltration in a 96-well filtrate assembly. The unbound fractions are then analyzed by fast liquid chromatography-tandem mass spectrometry (LC-MS/MS). Sample handling is automated by a robotic system. Employing a cocktail approach where multiple new chemical entities are allowed to bind to plasma proteins in the same well has further increased the throughput. We have validated the method with 12 commercially available compounds. The plasma protein binding data obtained by this method are comparable with the literature values. This method enables the determination of protein binding for 32 compounds in one single experiment instead of 1-2 compounds using the conventional methods.

Blood Proteins↗

Capillary electrophoresis-ion trap mass spectrometry analysis of Ziagen and its phosphorylated metabolites.

A capillary electrophoresis-ion trap mass spectrometry method with a time-segment program was developed to simultaneously analyze Ziagen and its phosphorylated metabolites such as carbovir monophosphate, carbovir diphosphate, and carbovir triphosphate. By using the time-segment program, the positively charged nucleoside analog and negatively charged nucleotides were separated and detected in a single electrophoretic run. The limits of detection were less than 2 micro M for all of the analytes. Calibration curves of the compounds showed excellent linearity over the range of 2-100 micro M. The capability of the method was demonstrated by analyzing Ziagen and its phosphorylated metabolites that were spiked in cellular extracts of human peripheral blood mononuclear cells at 20 micro M levels. Some endogenous nucleotides such as adenosine 5'-triphosphate, adenosine 5'-diphosphate, and adenosine 5'-monophosphate, were also detected in the cellular extracts.

Adenosine Triphosphate↗

Higher-throughput screening for Caco-2 permeability utilizing a multiple sprayer liquid chromatography/tandem mass spectrometry system.

In the current drug discovery environment, higher-throughput analytical assays have become essential to keep pace with the screening demands for drug metabolism and pharmacokinetics (DMPK) attributes. This has been dictated by advances primarily in chemical procedures, notably combinatorial and parallel syntheses, which has resulted in many-fold increases in the number of compounds requiring DMPK evaluation. Because of its speed and specificity, liquid chromatography/tandem mass spectrometry (LC/MS/MS) has become the dominant technology for sample analysis in the DMPK screening assays. For higher-throughput assays, analytical speed as well as other factors such as method development, data processing, quality control, and report generation, must be optimized. The four-way multiplexed electrospray interface (MUX), which allows for the analysis of four LC eluents simultaneously, has been adopted to maximize the rate of sample introduction into the mass spectrometer. Generic fast-gradient HPLC methods that are suitable for approximately 80% of the new chemical entities encountered have been developed. In-house-written software programs have been used to streamline information flow within the system, and for quality control by automatically identifying analytical anomalies. By integrating these components together with automated method development and data processing, a system capable of screening 100 compounds per week for Caco-2 permeability has been established.

Absorption↗