PubMed Health⌕ Search

Biomedical subjects

Elizabeth A Morris

Publications and source records attributed to Elizabeth A Morris.

23 records · Page 2Linked to original sources

Preoperative MR imaging-guided needle localization of breast lesions.

OBJECTIVE: MR imaging of the breast can depict cancer that is occult on mammography and at physical examination. Our study was undertaken to determine the ease of performance and the outcome of MR imaging-guided needle localization and surgical excision of breast lesions. MATERIALS AND METHODS: Retrospective review revealed 101 consecutive breast lesions that had preoperative MR imaging-guided needle localization with commercially available equipment, including a 1.5-T magnet with a breast surface coil, a dedicated biopsy compression device, and MR imaging-compatible hookwires. Imaging studies and medical records were reviewed. RESULTS: Histologic findings in these 101 lesions were carcinoma in 31 (30.7%), high-risk lesions (atypical ductal hyperplasia or lobular carcinoma in situ) in nine (8.9%), and benign lesions in 61 (60.4%). Fifteen (48.4%) of 31 carcinomas were ductal carcinoma in situ, and 16 (51.6%) were infiltrating carcinoma (size range, 0.1-2.0 cm; median, 1.2 cm). Carcinoma was found in 16 (45.7%) of 35 lesions detected in women with synchronous cancer, 10 (32.3%) of 31 lesions detected on MR imaging for problem solving, and five (14.3%) of 35 lesions detected on MR screening. The time range to perform MR imaging-guided localization was 15-59 min (median time, 31 min). Complications encountered in three cases were retained wire fragments in two and breakage of the wire tip in one. CONCLUSION: MR imaging-guided needle localization can be performed quickly and safely with commercially available equipment. The positive predictive value of MR imaging-guided needle localization (30.7%) was comparable to that reported for mammographically guided needle localization and was highest in women with synchronous breast cancer.

Adult↗

Breast lesions detected on MR imaging: features and positive predictive value.

OBJECTIVE: The purpose of this study was to analyze features of breast lesions detected on MR imaging that had subsequent biopsy and to determine the positive predictive value (PPV) of these features. MATERIALS AND METHODS: Retrospective review was performed of 100 consecutive solitary MR imaging-detected breast lesions that had MR imaging-guided needle localization and surgical excision. We described lesions, using terms found in a proposed breast MR imaging lexicon. Histologic findings were reviewed. RESULTS: Carcinoma was identified in 25 lesions (25%), including ductal carcinoma in situ (DCIS) in 13 (52%) and infiltrating carcinoma in 12 (48%). Carcinoma was found in 15 (25%) of 60 masses versus 10 (25%) of 40 nonmass lesions; most malignant masses (73%) were infiltrating carcinoma, whereas most malignant nonmass lesions (90%) were DCIS. The features with the highest PPV were spiculated margin (80% carcinoma), rim enhancement (40% carcinoma), and irregular shape (32% carcinoma) for mass lesions and segmental (67% carcinoma) or clumped linear and ductal enhancement (31% carcinoma) for nonmass lesions. Visually assessed kinetic patterns were not significant predictors of carcinoma, but washout was present in 70% of infiltrating carcinomas versus 9% of DCIS lesions (p < 0.01). Carcinoma was present in 17 (19%) of 88 lesions classified as suspicious versus eight (67%) of 12 lesions classified as highly suggestive of malignancy (p = 0.001). CONCLUSION: Among MR imaging-detected breast lesions referred for biopsy, carcinoma was found in 25%, of which half were DCIS. Features with the highest PPV were spiculated margin, rim enhancement, and irregular shape for mass lesions and segmental or clumped linear and ductal enhancement for nonmass lesions. Final assessment categories were significant predictors of carcinoma.

Adult↗

To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy?

OBJECTIVE: This study was undertaken to determine whether complete percutaneous excision rather than sampling of the mammographic target conveys any significant advantage or disadvantage at stereotactic 11-gauge vacuum-assisted biopsy. MATERIALS AND METHODS: A retrospective review was performed of 788 consecutive solitary lesions in which the mammographic target was excised (n = 466) or sampled (n = 322) at stereotactic 11-gauge vacuum-assisted biopsy. Medical records and histologic findings were reviewed to determine the frequency of sparing surgery, discordance, histologic underestimation, rebiopsy, complete histologic removal of cancer, and complications. Statistical comparisons were made using the Fisher's exact test. RESULTS: Complete excision rather than sampling of the mammographic target was associated with a significantly lower frequency of discordance (1/466, 0.2% vs 8/322, 2.5%; p = 0.004) and a trend toward fewer ductal carcinoma in situ underestimates (4/59, 6.8% vs 12/60, 20.0%; p = 0.07). Complete histologic removal of cancer was significantly more likely if the mammographic target was excised rather than sampled (19/91, 20.9% vs 7/106, 6.6%; p = 0.006); however, among 91 cancers in which the mammographic target was excised, surgery revealed residual cancer in 72 (79.1%). Complete excision rather than sampling of the mammographic target yielded no significant differences in the frequency of sparing surgery, atypical ductal hyperplasia underestimates, rebiopsy, or complications. CONCLUSION: Complete excision rather than sampling of the mammographic target was associated with lower frequencies of discordance and ductal carcinoma in situ underestimation but had no other advantage or disadvantage. Among cancers in which the mammographic target was excised, surgery revealed residual cancer in almost 80%.

Adult↗

Histologic heterogeneity of masses at percutaneous breast biopsy.

The purpose of this study was to determine whether different histologic findings are obtained from different areas of breast masses seen on mammography when targeted on stereotactic breast biopsy. Twenty-one masses (mean size, 1.8 cm; range, 0.7-5.5 cm) underwent stereotactic biopsy using a 14-gauge directional vacuum-assisted biopsy probe (Mammotome, Biopsys/Ethicon Endo-Surgery, Cincinnati, OH). The central and peripheral areas of the mass were targeted and biopsied separately, and histologic findings from the targeted center and periphery were compared. Six of 21 masses (29%) were heterogeneous, yielding different histologic results from the targeted center and periphery. In 4 heterogeneous masses, which constituted 4 of 21 masses (19%) in this study, surgical biopsy was recommended on the basis of findings obtained from only the center (n = 2) or the periphery (n = 2). Stereotactic biopsy findings in these 4 masses were atypia in 3 and radial scar in 1; none of these 4 masses had carcinoma at surgery. In all 4 masses that proved to be malignant, the diagnosis of carcinoma was made in specimens obtained from both the targeted center and the periphery of the mass. Breast masses can be heterogeneous, yielding different histologic findings from different areas of the mass. Our data suggest that sampling part but not all of a mass may miss certain histologic components of the mass, but should not result in a failure to diagnose carcinoma.

Administration, Cutaneous↗

Determination of the presence and extent of pure ductal carcinoma in situ by mammography and magnetic resonance imaging.

The purpose of this study was to compare the ability of magnetic resonance imaging (MRI) and mammography to determine the presence and extent of ductal carcinoma in situ (DCIS). Retrospective review of medical records of women who underwent MRI and mammographic examination during a 23-month period revealed 39 sites of pure DCIS in 33 breasts of 32 women. No invasive or microinvasive tumor was found. Women ranged in age from 34 to 79 years (mean age 53 years). In these 33 breasts, both MRI and mammography were done before surgery. Reports and images of mammography and MRI were reviewed to determine if each study was positive for the presence of single or multiple sites of DCIS and the imaging patterns associated with these sites. Of 33 breasts involved, DCIS was discovered by MRI alone in 21 (64%), by both MRI and mammography in 8 (24%), and by mammography alone in 1 (3%); in 3 breasts (9%), DCIS was found at mastectomy without findings on mammography or MRI. MRI had significantly higher sensitivity than mammography for DCIS detection (29/33=88% versus 9/33=27%, p<0.00001). Multiple sites of disease were present in five breasts; these were better demonstrated with MRI in three, mammography in one, and equally by both in one. The predominant enhancement pattern of DCIS on MRI was linear/ductal in 18 of 29 breasts (62%); mammography found calcifications associated with DCIS in 8 of 9 (89%). The nuclear grade of DCIS found with MRI and mammography was similar; size of lesions was larger on MRI; breast density did not impact results. In this study, MRI was significantly more sensitive than mammography in DCIS detection. In women with known or suspected DCIS, MRI may have an important role to play in assessing the extent of disease in the breast.

Adult↗