Nonlinearity in intracochlear pressure.

Nonlinearity exists in intracochlear pressure responses close to the cochlea's sensory tissue. Its characteristics are much like those of basilar membrane motion nonlinearity. Here several aspects of the pressure nonlinearity in the base of the gerbil cochlea are illustrated.

Acoustic Stimulation↗

Middle ear forward and reverse transmission in gerbil.

The middle ear transmits environmental sound to the inner ear. It also transmits acoustic energy sourced within the inner ear out to the ear canal, where it can be detected with a sensitive microphone as an otoacoustic emission. Otoacoustic emissions are an important noninvasive measure of the condition of sensory hair cells and to use them most effectively one must know how they are shaped by the middle ear. In this contribution, forward and reverse transmissions through the middle ear were studied by simultaneously measuring intracochlear pressure in scala vestibuli near the stapes and ear canal pressure. Measurements were made in gerbil, in vivo, with acoustic two-tone stimuli. The forward transmission pressure gain was about 20-25 dB, with a phase-frequency relationship that could be fit by a straight line, and was thus characteristic of a delay, over a wide frequency range. The forward delay was about 32 micros. The reverse transmission pressure loss was on average about 35 dB, and the phase-frequency relationship was again delaylike with a delay of about 38 mus. Therefore to a first approximation the middle ear operates similarly in the forward and reverse directions. The observation that the amount of pressure reduction in reverse transmission was greater than the amount of pressure gain in forward transmission suggests that complex motions of the tympanic membrane and ossicles affect reverse more than forward transmission.

Acoustic Impedance Tests↗

Recording depth and signal competition in heterodyne interferometry.

A common way to measure submicroscopic motion of the organ of Corti is heterodyne interferometry. The depth over which vibration can be accurately measured with heterodyne interferometry is determined by both the optics, which controls to what extent light from nonfocal planes reaches the photodetectors, and demodulation electronics, which determines to what extent signal generated by out-of-focal-plane light influences the measurements. The influence of a second reflecting surface is investigated theoretically and experimentally. By reviewing the theory of FM demodulation and showing tests with a Revox FM demodulator, it is demonstrated that the influence of a secondary signal on a measurement depends on the modulation index. Both high- and low-modulation index signals are encountered in heterodyne interferometry of the cochlea. Using a He-Ne-like diode laser (lambda = 638 nm), the border between low- and high-modulation signals is at a displacement of about 25-100 nm. Confocal interferometry reduces the magnitude of out-of-focus signals, and therefore their effect on vibration measurement. The response of the confocal system to reflected signals from two surfaces separated by distances encountered within the cochlear partition is shown. The results underscore the benefit of steep optical sectioning for intracochlear measurements.

Biomechanical Phenomena↗

Two-tone distortion in intracochlear pressure.

Two-tone distortion was measured in the intracochlear pressure in the base of the gerbil cochlea, close to the sensory tissue, where the local motions and forces of the organ of Corti can be detected. The measurements probe both the underlying nonlinear process that generates two-tone distortion, and the filtering and spreading of the distortion products. Some of our findings are as follows: (1) The observations were consistent with previous observations of two-tone distortion in BM motion [J. Neurophysiol. 77, 2385-2399 (1997); J. Neurophysiol. 78, 261-270 (1997)]. (2) Frequency sweeps show distortion product tuning and phase-versus-frequency behavior that is similar, but not identical, to single tone tuning. (3) The decay of distortion products with distance from the basilar membrane confirms the feasibility that they could drive the stapes by a direct fluid route, as proposed by Ren [Nat. Neurosci. 7, 333-334 (2004)]. (4) The phases of the distortion products within a single family (the group of distortion products generated by a single primary pair) in some cases alternated between 0 degrees and 180 degrees when referenced to the phases of the primaries. This behavior is predicted by a simple compressive nonlinearity.

Acoustic Stimulation↗

Harmonic distortion in intracochlear pressure and its analysis to explore the cochlear amplifier.

Intracochlear pressure was measured close to the basal basilar membrane in gerbil with pure-tone stimulation. This report describes harmonic distortion in the pressure. The harmonic components were tuned in frequency and physiologically vulnerable, implying that they were related to the cell-derived force that sharpens tuning at low levels in healthy cochleae. For stimulus frequencies in the vicinity of the best frequency the harmonic distortion appeared to be produced locally, at the place of measurement. Therefore, it could be explored with a local nonlinear model. The combined model and observations demonstrate two specific points: First, the harmonics in the cell-based force were likely similar in size to the harmonics in pressure (multiplied by area) close to the basilar membrane. This is distinctly different than the situation for the fundamental component, where the cell-based force is apparently much smaller than the pressure (times area). Second, although the fundamental component of the measured pressure was much larger than its harmonic components, the harmonic and fundamental components of the active force were likely much more similar in size. This allows the harmonic components in the pressure to be used as an indirect measure of the active force.