PubMed Health⌕ Search

Biomedical subjects

Elizabeth S Soileau

Publications and source records attributed to Elizabeth S Soileau.

8 recordsLinked to original sources

Polyethylene liner exchange of the Harris-Galante porous I and II acetabular components without cement: results and complications.

This study reviewed the long-term efficacy of the locking mechanism of the Harris-Galante porous (HGP) I and II acetabular components and the results and complications of polyethylene liner exchange without cement. There were 400 HGP-I components with a mean follow-up of 10 years (range, 2-19 years) and 78 HGP-II components with 8 years of mean follow-up (range, 2-13 years). There has been only 1 liner dislodgement (0.2%). Thirty-five hips (34 patients) have undergone liner exchange without cement. The index acetabular component was implanted as a primary procedure in 19 hips and a revision in 16 hips. No exchanged liner has dislodged at a mean follow-up time of 5.1 years (range, 2-11 years). However, there have been 7 patients (20%) with recurrent dislocation and all required reoperation. Dislocation was significantly lower when an elevated rim liner was used.

Acetabulum↗

Ten-year survival and clinical results of constrained components in primary total knee arthroplasty.

The use of constrained prostheses in primary total knee arthroplasty (TKA) is unusual. This is a study of the indications, clinical results, and 10-year survival of these components. Fifty-four knees (44 patients) were prospectively followed, and 42 knees (34 patients) had 5 to 16 years (mean, 9 years) of follow-up. The indications for the components were valgus deformity with incompetent medial collateral ligament in 27 knees, severe flexion contracture with inability to balance the knee in 12, and others in 3. Knees were evaluated by the Hospital for Special Surgery and Knee Society score systems. Statistical analysis included paired Student t test and survivorship analysis. Of the entire cohort of 54 knees, there were only 2 failures: a tibial loosening revised at 3 years and a femoral loosening (no stem) revised at 1 year. Of the 42 knees with minimum 5-year follow-up, 12 knees were rated as excellent, 24 good, 3 as fair, and 3 as poor. There was a significant improvement in postoperative knee score, but not in the function score. The mean flexion contracture preoperatively was 17 degrees; postoperatively, 1.7 degrees; and mean flexion preoperatively, 93 degrees; postoperatively, 97 degrees. The 10-year survival with failure, defined as component revision for loosening, was 96% (confidence interval, 90.6%-100%). In difficult primary TKAs, there were 86% good or excellent results and a 10-year survival of 96% despite the increased constraint. The constrained condylar TKA remains indicated for knees with severe valgus deformity, incompetent medial collateral ligament, or severe flexion contracture in which the knee cannot be properly balanced.

Adult↗

Patella maltracking in posterior-stabilized total knee arthroplasty.

Maltracking of the patella component in total knee arthroplasty usually leads to complications such as subluxation, dislocation, fracture, excessive wear, or implant failure. After using a new posterior-stabilized total knee arthroplasty and a specific protocol for the patellofemoral articulation we determined the incidence of lateral retinacular release and patella complications. We retrospectively reviewed 255 consecutive primary posterior-stabilized total knee arthroplasties with an anatomic femoral component and a three-peg offset-dome patella. Component alignment was achieved using Whiteside's lines for the femoral component, the medial border of the tubercle for the tibial component, and previously reported techniques for the patella. Lateral release was performed in 15 knees (6.2%), most of which had excessive preoperative valgus (mean, 15 degrees). There were no reoperations for the patellofemoral joint at a mean followup of 3.7 years (range, 2-7 years). Two patients had asymptomatic osteonecrosis of the patella with complete radiolucent lines, and one patella fracture was treated with immobilization. We believe patella maltracking a largely avoidable problem in total knee arthroplasty. We found a low incidence of lateral retinacular release and patella complications using these components and this protocol for the patellofemoral articulation.

Aged↗

Dislocation of primary total hip arthroplasty with 36 and 40-mm femoral heads.

Some authors suggest the use of larger (36 and 40 mm) femoral heads against highly cross-linked polyethylene acetabular liners will reduce the prevalence of early dislocation after primary total hip arthroplasty (THA). We prospectively followed 61 consecutive patients at high risk for dislocation to determine the prevalence of early dislocation after primary THA with 36 and 40 mm femoral heads. We established specific indications for the use of these larger heads in primary arthroplasty. There were 65 hips in 61 patients with a minimum followup of 1 year (mean 2 years, range 1-4 years). There were 55 36 mm heads and 10 40 mm heads. All arthroplasties were performed by the posterior approach with capsular repair. The prevalence of early dislocation was 4.6% (3 of 65). There was one patient with an anterior dislocation and two with posterior dislocation. No patient underwent reoperation for dislocation. There was no dislocation in the 10 hips that had a 40 mm head. We identified no complications related to the larger femoral heads. The use of larger femoral heads did not notably reduce the prevalence of early dislocation after primary THA in high risk patients compared to historical controls.

Aged↗

Multimodal prophylaxis for THA with mechanical compression.

We used mechanical thromboembolism prophylaxis using intraoperative thigh-calf pneumatic compression and other measures in 1032 consecutive primary and revision total hip arthroplasties. No chemical prophylactic measures were used until after duplex ultrasonography was performed by experienced technologists before discharge. Asymptomatic proximal thrombi were treated with low molecular weight heparin and warfarin, whereas those patients with a negative scan or distal thrombi only were advised to take aspirin 325 mg twice a day for 6 weeks. Regional anesthesia was used in 95% of the arthroplasties. Using this protocol, the 30-day mortality was 0.3%. There was one autopsy-proven fatal pulmonary embolism (0.09%). One other patient died suddenly with cardiac arrest after abdominal pain and vomiting, but no autopsy was performed. Symptomatic pulmonary embolism occurred in seven patients (0.7%), four occurring early and three late. Only one of these seven patients had a positive duplex scan. Deep vein thrombosis occurred in 41 patients (3.9%) and 35 remained asymptomatic. We observed no association between type of surgery (primary or revision), age, gender or preoperative diagnosis and pulmonary embolism or deep vein thrombosis. The data confirm the efficacy of a multimodal protocol with thigh-calf mechanical prophylaxis for almost all patients undergoing primary or revision total hip arthroplasty.

Adult↗

Changing indications for revision total hip arthroplasty.

This was a retrospective review of two cohorts of 100 consecutive revisions performed 10 years apart by one surgeon, to determine the major reason for reoperation. For the early cohort, the indications for revision were: loosening of both components (38%), loosening of acetabular component (22%), loose hemiarthroplasty (13%), infection (10%), loosening of femoral component (8%), periprosthetic fracture (6%), recurrent dislocation (2%), and wear (1%). For the recent cohort, the indications for revision have significantly changed: loosening of acetabular component (24%), loosening of femoral component (22%) (p = .0048), recurrent dislocation (16%) (p = .0011), loosening of both components (15%) (p = .0002), wear-osteolysis (7%) (p = .03), infection (7%), loose hemiarthroplasty (6%), and periprosthetic fracture (3%). There has been a change in the indications for revision hip arthroplasty compared with 10 years ago, with a statistically significant increase in revisions for dislocation, wear-osteolysis, and loosening of the femoral component only.

Adult↗

The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.

BACKGROUND: Osteolysis and increased polyethylene wear have been reported in association with several designs of modular total knee prostheses. The purpose of the present study was to evaluate a modular posterior stabilized prosthesis to determine its clinical performance as well as the rates of component loosening and osteolysis. METHODS: We performed a prospective, consecutive study of 193 knees in 131 patients who were managed with the modular Insall-Burstein II posterior stabilized total knee prosthesis by one surgeon. The mean age of the patients at the time of surgery was sixty-eight years, and the mean duration of follow-up was seven years (range, five to fourteen years). Clinical evaluation was performed with use of standard knee-scoring systems. Radiographs were evaluated for the presence of radiolucent lines, osteolysis, and loosening. RESULTS: The overall result (as determined with the Hospital for Special Surgery scoring system) was rated as excellent for 112 knees, good for sixty, fair for fifteen, and poor for six. The mean postoperative flexion was 112 degrees. No clinical or radiographic loosening of the tibial component was noted. Eight knees had osteolytic lesions of the tibia. Thin, incomplete, nonprogressive radiolucent lines were noted around thirty tibial components (16%). There were three reoperations. CONCLUSIONS: Despite previous reports of osteolysis, polyethylene wear, and loosening in association with some modular total knee implant designs, there was no loosening in this series of posterior stabilized total knee replacements and only eight knees had tibial osteolysis after a mean duration of follow-up of seven years. We believe that total knee arthroplasties that are performed with use of cemented modular posterior stabilized components can have a high rate of intermediate-term success. LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Activities of Daily Living↗

Stability of total hip arthroplasty in patients 75 years or older.

Increasing patient age (> 75 years) is a known risk factor for dislocation of total hip arthroplasty. This is a study of total hip arthroplasties by one surgeon in patients 75 years or older to determine the prevalence of dislocation and a review of the surgical options for prevention and treatment of instability in this population. Of 140 primary total hip arthroplasties done in patients 75 years or older who were followed up for at least 1 year, the preoperative diagnosis was osteoarthritis in 82% and the mean followup time was 4 years. The acetabular component was cementless: modular in 121 arthroplasties and cemented in 19 arthroplasties. There were five dislocations (3.5%), but only two were recurrent and the patients were treated successfully by modular component exchange. Bipolar arthroplasty has a lower rate of dislocation, but there are problems with residual pain and high rates of reoperation, wear, and osteolysis. Constrained components may be indicated in older patients with dementia, abductor insufficiency, or failure of modular exchange. Large femoral heads, to increase the range of motion before dislocation occurs, may be used with highly cross-linked acetabular liners. Modular cementless acetabular components are preferable in patients who are 75 years or older. A 28-mm or 32-mm femoral head is recommended, but larger femoral heads should be considered in patients with fractures and for the treatment of recurrent dislocation.

Aged↗