PubMed Health⌕ Search

Biomedical subjects

Elka Miller

Publications and source records attributed to Elka Miller.

8 recordsLinked to original sources

Percutaneous drainage as the treatment of choice for neonatal ovarian cysts.

BACKGROUND: Involution of neonatal ovarian cysts occurs usually by 12 months. Persisting cysts larger than 4 cm are prone to torsion. Two modes of therapy are advocated: surgery and percutaneous US-guided cyst aspiration. OBJECTIVE: To compare ovarian preservation following the use of US-guided aspiration or conventional surgery for the treatment of large asymptomatic neonatal ovarian cysts, and to suggest alternative treatment when intrauterine ovarian torsion occurs. MATERIALS AND METHODS: The study population comprised 25 baby girls with an ovarian cyst, 5 with a simple cyst and 20 with a complex cyst. Of these 25 infants, 8 had surgery and 17 had US-guided cyst aspiration. RESULTS: In the surgical group of 8, 6 underwent oophorectomy, and in 2 the ovary was saved. In the aspirated group of 17, the ovary was saved in 10, and was lost in 5. At the time of this report one patient was still in the follow-up period, and one was lost to follow-up. CONCLUSION: US-guided aspiration of large neonatal cysts preserves ovarian tissue in a higher percentage of patients than surgery. It is safe, effective, and repeatable. We recommend US-guided aspiration of asymptomatic large ovarian cysts for salvage or for decompression if intrauterine ovarian torsion occurs. Surgery should be reserved for patients with acute torsion, intestinal obstruction and intestinal volvulus.

Drainage↗

Impact of prenatal magnetic resonance imaging on postnatal neurosurgical treatment.

OBJECT: The goal of this study was to determine the importance magnetic resonance (MR) imaging holds as a complementary fetal imaging modality to ultrasonography in deciding postnatal neurosurgical management. METHODS: Between 1999 and 2003, 320 fetal MR imaging studies were performed at a single institution. Twenty-four fetuses were found to have central nervous system abnormalities that could potentially require a neurosurgical intervention. The diagnoses included spinal anomalies (scoliosis, myelomeningocele, and closed spinal dysraphism) and brain anomalies (ventriculomegaly with or without hemorrhage, intracranial cyst, craniosynostosis, and encephalocele). Fourteen of the 24 fetuses underwent surgery based on findings of prenatal MR imaging. In seven cases the pregnancy was terminated, and in three cases conservative follow up continues. CONCLUSIONS: In a variety of brain and spine disorders, prenatal MR imaging can delineate and characterize the abnormality, and thus assist in the diagnosis and in the planning of postnatal surgery and management. This modality provides important multiplanar images and may obviate the need for early postnatal computed tomography or MR imaging. Postnatal management can often be guided by prenatal MR imaging findings.

Brain↗

18F-FDG PET/CT in the evaluation of adrenal masses.

UNLABELLED: Our purpose was to evaluate the performance of (18)F-FDG PET/CT, using data from both the PET and the unenhanced CT portions of the study, in characterizing adrenal masses in oncology patients. METHODS: One hundred seventy-five adrenal masses in 150 patients referred for (18)F-FDG PET/CT were assessed. Final diagnosis was based on histology (n = 6), imaging follow-up (n = 118) of 6-29 mo (mean, 14 mo), or morphologic imaging criteria (n = 51). Each adrenal mass was characterized by its size; its attenuation on CT, expressed by Hounsfield units (HU); and the intensity of (18)F-FDG uptake, expressed as standardized uptake value (SUV). Receiver operating characteristic curves were drawn to determine the optimal cutoff values of HU and SUV that would best discriminate between benign and malignant masses. RESULTS: When malignant lesions were compared with adenomas, PET data alone using an SUV cutoff of 3.1 yielded a sensitivity, specificity, positive predictive value, and negative predictive value of 98.5%, 92%, 89.3%, 98.9%, respectively. For combined PET/CT data, the sensitivity, specificity, positive predictive value, and negative predictive value were 100%, 98%, 97%, 100%, respectively. Specificity was significantly higher for PET/CT (P < 0.01). Fifty-one of the 175 masses were 1.5 cm or less in diameter. When a cutoff SUV of 3.1 was used for this group, (18)F-FDG PET/CT correctly classified all lesions. CONCLUSION: (18)F-FDG PET/CT improves the performance of (18)F-FDG PET alone in discriminating benign from malignant adrenal lesions in oncology patients.

Adolescent↗

Solid splenic masses: evaluation with 18F-FDG PET/CT.

UNLABELLED: Our objective was to assess the role of (18)F-FDG PET/CT in the evaluation of solid splenic masses in patients with a known malignancy and in incidentally found lesions in patients without known malignancy. METHODS: Two groups of patients were assessed: (a) 68 patients with known malignancy and a focal lesion on PET or a solid mass on CT portions of the PET/CT study; and (b) 20 patients with solid splenic masses on conventional imaging without known malignancy. The standard of reference was histology (n = 16) or imaging and clinical follow-up (n = 72). The lesion size, the presence of a single versus multiple splenic lesions, and the intensity of (18)F-FDG uptake expressed as a standardized uptake value (SUV) were recorded. The ratio of the SUV in the splenic lesion to the background normal splenic uptake was also calculated. These parameters were compared between benign and malignant lesions within each of the 2 groups of patients and between the 2 groups. RESULTS: The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of (18)F-FDG PET/CT in differentiating benign from malignant solid splenic lesions in patients with and without malignant disease were 100%, 100%, 100%, and 100% versus 100%, 83%, 80%, and 100%, respectively. In patients with known malignant disease, an SUV threshold of 2.3 correctly differentiated benign from malignant lesions with the sensitivity, specificity, PPV, and NPV of 100%, 100%, 100%, and 100%, respectively. In patients without known malignant disease, false-positive results were due to granulomatous diseases (n = 2). CONCLUSION: (18)F-FDG PET can reliably discriminate between benign and malignant solid splenic masses in patients with known (18)F-FDG-avid malignancy. It also appears to have a high NPV in patients with solid splenic masses, without known malignant disease. (18)F-FDG-avid splenic masses in patients without a known malignancy should be further evaluated as, in our series, 80% of them were malignant.

Adolescent↗

The clinical impact of camera-based positron emission tomography imaging in patients with recurrent colorectal cancer.

RATIONALE AND OBJECTIVES: F18-fluorodeoxyglucose (FDG)-positron emission tomography (PET) studies have clinical value in suspected recurrent or metastatic colorectal cancer cases. Because this modality is not accessible for many patients, a camera-based FDG (CB-FDG) coincidence imaging was suggested as an alternative. Although inferior in resolution to a dedicated PET system, it can make FDG studies available to more patients. We assessed the clinical value of CB-FDG in patients with recurrent colorectal cancer. METHODS: The disease stage and treatment approach in 83 patients were twice determined by an oncologist and a surgeon, first based on the patient's records and blind to CB-FDG findings and then with the inclusion of FDG results in the decision-making analysis. RESULTS: On a lesion-based analysis, the sensitivity of CB-FDG was 95% and the specificity was 81% compared with 88% and 64%, respectively, for computed tomography. Adding FDG findings led to disease-stage alteration in 47 patients (57%), upstaging in 35 (42%), and downstaging in 12 (15%). FDG localized the tumor sites in 21 of 26 patients (81%) with suspected clinical recurrence and a negative conventional imaging workup. In 8 patients, FDG ruled out viable tumor tissue suggested by other modalities. The oncologist's suggested treatment approach was altered in 54% of the patients and the surgeon altered the decision on operability in 28%. CONCLUSION: CB-FDG assessment has clinical value for both staging and selecting treatment in patients with recurrent colorectal cancer and can be considered an alternative to an nonaccessible dedicated PET system.

Adult↗

Coincidence imaging using 2 dual-head gamma-camera systems, with and without attenuation correction.

OBJECTIVE: Coincidence imaging enhances the potential for imaging a greater number of patients with 18F-FDG in centers that do not have dedicated PET systems. The purpose of this study was to compare, in a clinical setting, coincidence imaging for tumor detection using 2 dual-head gamma-camera systems, one equipped with a 5/8-in. (16 mm) detector (CoDe5) and the other equipped with a newly designed 1-in. (25.4 mm) detector (CoDe8) with an x-ray tube installed in its gantry. METHODS: Thirty consecutive patients were studied by both systems during the same visit and had 4 image sets for comparison: CoDe5 without attenuation correction (CoDe5NC), CoDe8 with (CoDe8AC) and without (CoDe8NC) attenuation correction, and fused coincidence-CT images. The target-to-background ratio (T/Bg ratio) and target-to-nontarget ratio (T/NT ratio) were calculated for each tumor site. RESULTS: On visual assessment, 61 tumor sites were detected on CoDe8AC images. Of these, 59 (97%) were detected on CoDe8NC and 54 (88%) were detected on CoDe5NC images. Fused images improved image interpretation in 10 patients (33%) compared with coincidence images alone. Data added by fusion were of clinical relevance in 6 patients (20%). On quantitative assessment, the number of accepted events by the CoDe8 was significantly higher than that by CoDe5 (5.21 +/- 1.46 million vs. 1.27 +/- 0.36 million, P <0.001). When comparing CoDe5 with CoDe8 images without attenuation correction, the T/Bg and T/NT ratios were significantly higher on the CoDe8 images (P <0.0005 and P <0.0005, respectively). When comparing CoDe8 images with and without attenuation correction, the T/Bg ratio was better on the attenuation-corrected images (P <0.0005). CONCLUSION: Coincidence imaging with 1-in. detectors and attenuation correction improve image quality and, to a lesser extent, the tumor detection rate compared with the 5/8-in. detectors and noncorrected images. The data added by fusion of coincidence images to CT findings were clinically relevant in 20% of the patients.

Adult↗

Mass at the splenic hilum: a clue to torsion of a wandering spleen located in a normal left upper quadrant position.

Wandering spleen is an extremely rare condition in which the spleen is lacking its normal ligamentous attachments and therefore can move to an ectopic position in the abdomen or pelvis. Wandering spleen predisposes the patient to life-threatening complications due to torsion of the spleen's vascular pedicle, with resulting splenic infarction, portal hypertension, and bleeding. Because of the nonspecific symptoms, imaging plays an important role. To our knowledge, only a few case reports describing wandering spleen in the pediatric population have been published, including 2 cases in infancy. We report a case of splenic torsion in an infant with a preoperative diagnosis made on the basis of color and power Doppler sonography. The diagnosis was confirmed by contrast-enhanced helical computed tomography (CT) and proved at surgery. On sonography, a diffusely hypoechoic spleen and a mass at the splenic hilum representing the torsed splenic pedicle were shown. The splenic hilar mass correlates with the CT "whirl" sign indicative of torsion.

Choristoma↗

Role of 18F-FDG PET/CT in staging and follow-up of lymphoma in pediatric and young adult patients.

OBJECTIVE: To assess the role of 18F-Fluorodeoxyglucose (18F-FDG) PET/CT in pediatric patients with Hodgkin disease (HD) and non-Hodgkin lymphoma (NHL). MATERIALS AND METHODS: 31 patients, mean age 12.9 +/- 5.1, HD (n = 24), and NHL (n = 7) underwent 18F-FDG PET/CT at diagnosis (n = 31 studies) and later in the course of the disease (n = 75 studies). The findings of PET/CT were correlated with diagnostic CT and clinical follow-up. RESULTS: PET/CT findings resulted in a change of disease staging in 10 patients (32.3%), upstaging in 7 (22.6%) and downstaging in 3 (9.6%). On a lesion analysis, 164 disease sites were detected by PET/CT of which 38 were overlooked by DCT. At mid-treatment, PET was negative in 28 out of 31 patients (90%) with negative predictive value of 96% as all latter patients except for 1, were disease free (mean 15.4 +/- 8.8 months). The positive predictive value of persistent increased 18F-FDG uptake was 100% as 3 patients with latter findings had active disease. On the CT part, 76 residual masses were identified in 22 patients. Increased 18F-FDG uptake was detected in 11 masses in 4 patients who had active disease. Remaining 65 PET negative masses were false positive findings. The positive predictive value of residual CT mass was 14%. CONCLUSIONS: PET/CT is associated with change in staging in approximately 1 out of 3 pediatric patients with HD and NHL. When used for monitoring response to treatment, a negative study is associated with disease-free period, even when residual mass is detected. A positive PET study indicates residual malignant disease.

Adolescent↗