PubMed Health⌕ Search

Biomedical subjects

Ellie L Francis

Publications and source records attributed to Ellie L Francis.

4 recordsLinked to original sources

The relation of axial length and intraocular pressure fluctuations in human eyes.

PURPOSE: To determine in human eyes whether diurnal fluctuations in axial length are related to fluctuations in intraocular pressure (IOP) by studying these fluctuations in both eyes of individual subjects and by assessing the regularity of both rhythms on two separate study days. METHODS: Ten subjects, ages 18 to 24 years, underwent serial axial length and IOP measurements using highly precise, noncontact partial coherence interferometry and Goldmann applanation tonometry, respectively. Both eyes were measured at six 3-hour intervals during each of two study days, and significant fluctuations were modeled by sine curves. RESULTS: Of the 40 data sets, 29 had significant axial length high-low differences and 32 had significant IOP high-low differences (ANOVA, P < 0.05 for each). The magnitude of the significant high-low differences were 38 +/- 22 microm for axial length and 6.0 +/- 1.9 mm Hg for IOP (mean +/- SD). Neither axial length nor IOP fluctuations necessarily occurred bilaterally on the same day, and neither rhythm was regularly observed on two separate days in individual eyes. In eyes in which both parameters fluctuated on the same day, there were no correlations in the amplitude, period or phase of the two rhythms. CONCLUSIONS: Both axial length and IOP fluctuate during the day much of the time in most subjects. However, diurnal IOP fluctuations do not appear to cause diurnal axial length fluctuations.

Adolescent↗

Diurnal axial length fluctuations in human eyes.

PURPOSE: This study sought diurnal variations of eye length in human subjects, analogous to those reported in laboratory animals. METHODS: Seventeen subjects, ages 7 to 53 (median 16) years and mean spherical equivalent refractive error -0.68 D (range, -3.00 to +1.00 D), underwent axial length measurements at multiple times during the day between 7 AM and 1 AM the following day, using partial coherence interferometry (PCI), a highly precise, noncontact method. Diurnal axial length measurements were obtained on two or more days in 10 of these subjects. RESULTS: During at least 1 day, 15 subjects showed a statistically significant (ANOVA, P < 0.05) diurnal fluctuation of axial length, with a magnitude generally between 15 and 40 microm. From the diurnal tracings that fit a sine curve using statistical criteria, the mean period of fluctuation was 21.6 +/- 4.33 hours (SD), the mean amplitude was 27.1 +/- 11.9 microm (SD; range, 12.8-41.4 microm), and the maximum axial length tended to occur at midday. Each of the subjects with multiple daily measurements showed axial length fluctuations on at least 1 day, but there were day-to-day differences in the diurnal variations: most notably, four subjects showed axial length fluctuations on each day; in others, the fluctuations were not observed on each testing day. CONCLUSIONS: The human eye undergoes diurnal fluctuations in axial length, with a pattern suggesting maximum axial length at midday. Based on repeated measurements, these daily fluctuations may not appear regularly in all subjects, suggesting the possibility of physiologic influences that must be defined.

Adolescent↗

Highly precise eye length measurements in children aged 3 through 12 years.

OBJECTIVE: To determine the feasibility, reliability, and validity of using partial coherence interferometry, a noncontact method that detects interference patterns from various layers of the eye, to measure axial length in young children. METHODS: The right eye of 64 subjects (mean age, 8.4 y; age range, 3.4-12.9 y; best-corrected visual acuity >or=20/30) was measured. Subjects fixated monocularly on the collimated light pattern from a laser diode (the alignment beam) and the operator used a video monitor to align the corneal reflection in the optical path. Axial length was measured during an 0.8-second scan using interference patterns from a collimated short coherence superluminescence diode aligned coaxially with the laser diode. Five series of 16 readings each were obtained. The average axial length for each of the 5 series of readings was calculated. Main Outcome Measure Axial length. RESULTS: Within-subject precision of axial length measurements was high, with an overall SE of measurement of 8 micro m for individual subjects across the 5 sessions (95% confidence interval, +/-16 micro m). Subgroup analysis showed that sex, age, spherical equivalent, and refractive error exerted statistically significant effects on precision, but all of the differences among subgroups were 3 micro m or less and likely to be insignificant clinically. Axial length measured by partial coherence interferometry varied systematically, with factors known to influence eye length (ie, age and refractive error), further validating the measurement method. CONCLUSION: The partial coherence interferometry technique provides reproducible, extraordinarily precise eye length measurements in young children and should enable novel approaches to study eye growth and refractive development.

Body Weights and Measures↗

Accommodation and vergence require effort-to-see.

PURPOSE: Accommodation and vergence both appear to be influenced by multiple nonsensory factors. "Effort-to-see" is one of these factors. This study was designed to assess the extent to which effort-to-see affects accommodation and vergence. METHOD: Nine volunteers participated in this study. Stimuli were chosen to stimulate selectively either accommodation or vergence. Accommodation and vergence responses were measured while observers viewed each stimulus with the instruction of "concentrate" or "space-out." RESULTS: Both oculomotor adjustments were accurate when observers "concentrated," but regressed toward the resting posture during identical stimulus conditions when observers spaced-out. Interesting, individual differences in oculomotor behavior were apparent. CONCLUSION: This study demonstrates that higher-level attentional factors play an important role in accommodation and vergence for active exploration of the three-dimensional environment.

Accommodation, Ocular↗