PubMed Health⌕ Search

Biomedical subjects

Elliot McVeigh

Publications and source records attributed to Elliot McVeigh.

11 recordsLinked to original sources

Measuring mechanical function in the failing heart.

A common pathology in heart failure is a detrimental change in the mechanics of both contraction and filling. In familial hypertrophic cardiomyopathy, a genetic disease characterized by left ventricular hypertrophy and myofiber disarray, left ventricular diastolic dysfunction is common and contributes to congestive heart failure. In dilated cardiomyopathy, a common correlate to reduced wall thickening and increased chamber volume is an asynchronous activation of the left ventricle due to left bundle branch block. Local measures of the timing and magnitude of myocardial shortening and relaxation can be obtained with magnetic resonance (MR) tissue tagging, MR cine phase contrast, or MR cine displacement encoding. In familial hypertrophic cardiomyopathy, these methods have been shown to quantify the restrictive filling of the ventricle. Characterizing the regions of the failing heart which are activated late has allowed investigators to measure the change in protein expression in those regions compared to normal myocardium. Also, these MR imaging methods have led to a better quantification of the asynchronous activation in dilated cardiomyopathy, which can be used to predict response to resynchronization therapy with pacing.

Adult↗

Building maps of local apparent conductivity of the epicardium with a 2-D electrophysiological model of the heart.

In this paper, we address the problem of estimating the parameters of an electrophysiological model of the heart from a set of electrical recordings. The chosen model is the reaction-diffusion model on the transmembrane potential proposed by Aliev and Panfilov. For this model of the transmembrane, we estimate a local apparent two-dimensional conductivity from a measured depolarization time distribution. First, we perform an initial adjustment including the choice of initial conditions and of a set of global parameters. We then propose a local estimation by minimizing the quadratic error between the depolarization time computed by the model and the measures. As a first step we address the problem on the epicardial surface in the case of an isotropic version of the Aliev and Panfilov model. The minimization is performed using Brent method without computing the derivative of the error. The feasibility of the approach is demonstrated on synthetic electrophysiological measurements. A proof of concept is obtained on real electrophysiological measures of normal and infarcted canine hearts.

Action Potentials↗

Evidence of structural remodeling in the dyssynchronous failing heart.

Ventricular remodeling of both geometry and fiber structure is a prominent feature of several cardiac pathologies. Advances in MRI and analytical methods now make it possible to measure changes of cardiac geometry, fiber, and sheet orientation at high spatial resolution. In this report, we use diffusion tensor imaging to measure the geometry, fiber, and sheet architecture of eight normal and five dyssynchronous failing canine hearts, which were explanted and fixed in an unloaded state. We apply novel computational methods to identify statistically significant changes of cardiac anatomic structure in the failing and control heart populations. The results demonstrate significant regional differences in geometric remodeling in the dyssynchronous failing heart versus control. Ventricular chamber dilatation and reduction in wall thickness in septal and some posterior and anterior regions are observed. Primary fiber orientation showed no significant change. However, this result coupled with the local wall thinning in the septum implies an altered transmural fiber gradient. Further, we observe that orientation of laminar sheets become more vertical in the early-activated septum, with no significant change of sheet orientation in the late-activated lateral wall. Measured changes in both fiber gradient and sheet structure will affect both the heterogeneity of passive myocardial properties as well as electrical activation of the ventricles.

Animals↗

Cardiac dyssynchrony analysis using circumferential versus longitudinal strain: implications for assessing cardiac resynchronization.

BACKGROUND: QRS duration is commonly used to select heart failure patients for cardiac resynchronization therapy (CRT). However, not all patients respond to CRT, and recent data suggest that direct assessments of mechanical dyssynchrony may better predict chronic response. Echo-Doppler methods are being used increasingly, but these principally rely on longitudinal motion (epsilonll). It is unknown whether this analysis yields qualitative and/or quantitative results similar to those based on motion in the predominant muscle-fiber orientation (circumferential; epsiloncc). METHODS AND RESULTS: Both epsilonll and epsiloncc strains were calculated throughout the left ventricle from 3D MR-tagged images for the full cardiac cycle in dogs with cardiac failure and a left bundle conduction delay. Dyssynchrony was assessed from both temporal and regional strain variance analysis. CRT implemented by either biventricular (BiV) or left ventricular-only (LV) pacing enhanced systolic function similarly and correlated with improved dyssynchrony based on epsiloncc-based metrics. In contrast, longitudinal-based analyses revealed significant resynchronization with BiV but not LV for the overall cycle and correlated poorly with global functional benefit. Furthermore, unlike circumferential analysis, epsilonll-based indexes indicated resynchronization in diastole but much less in systole and had a lower dynamic range and higher intrasubject variance. CONCLUSIONS: Dyssynchrony assessed by longitudinal motion is less sensitive to dyssynchrony, follows different time courses than those from circumferential motion, and may manifest CRT benefit during specific cardiac phases depending on pacing mode. These results highlight potential limitations to epsilonll-based analyses and support further efforts to develop noninvasive synchrony measures based on circumferential deformation.

Animals↗

Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI.

Segmented cine MRI generally requires breath-holding, which can be problematic for many patients. Navigator echo techniques, particularly successful for free-breathing coronary MRA, are incompatible with the acquisition strategies and SSFP pulse sequences commonly used for cine MRI. The purpose of this work is to introduce a new self-gating technique deriving respiratory gating information directly from the raw imaging data acquired for segmented cine MRI. The respiratory self-gating technique uses interleaved radial k-space sampling to provide low-resolution images in real time during the free-breathing acquisition that are compared to target expiration images. Only the raw data-producing images with high correlation to the target images are included in the final high-resolution reconstruction. The self-gating technique produced cine series with no significant differences in quantitative image sharpness to series produced using comparable breath-held techniques. Because of the difficulties associated with breath-holding, the respiratory self-gating technique represents an important practical advance for cardiac MRI. , Inc.

Algorithms↗

Transvenous access to the pericardial space: an approach to epicardial lead implantation for cardiac resynchronization therapy.

BACKGROUND: Percutaneous access to the pericardial space (PS) may be useful for a number of therapeutic modalities including implantation of epicardial pacing leads. We have developed a catheter-based transvenous method to access the PS for implanting chronic medical devices. METHODS: In eight pigs, a transseptal Mullins sheath and Brockenbrough needle were introduced into the right atrium (RA) from the jugular vein under fluoroscopic guidance. The PS was entered through a controlled puncture of the terminal anterior superior vena cava (SVC) (n = 7) or right atrial appendage (n = 1). A guidewire was advanced through the transseptal sheath, which was then removed leaving the wire in PS. The guidewire was used to direct both passive and active fixation pacing leads into the PS. Pacing was attempted and lead position was confirmed by cine fluoroscopy. Animals were sacrificed acutely and at 2 and 6 weeks. RESULTS: All animals survived the procedure. Pericardial effusion (PE) during the procedure was hemodynamically significant in four of the eight animals. At necropsy, lead exit sites appeared to heal without complication at 2 and 6 weeks. Volume of pericardial fluid was 10.8 +/- 6.2 mL and appeared normal in four of the six chronic animals. Moderate fibrinous deposition was observed in two animals, which had exhibited significant over-procedural PE. CONCLUSIONS: Access to the PS via a transvenous approach is feasible. Pacing leads can be negotiated into this region. The puncture site heals with the lead in place. Further development should focus on eliminating PE and performing this technique in appropriate heart failure models.

Animals↗

MRI-guided HDR prostate brachytherapy in standard 1.5T scanner.

PURPOSE: Magnetic resonance imaging (MRI) provides superior visualization of the prostate and surrounding anatomy, making it the modality of choice for imaging the prostate gland. This pilot study was performed to determine the feasibility and dosimetric quality achieved when placing high-dose-rate prostate brachytherapy catheters under MRI guidance in a standard "closed-bore" 1.5T scanner. METHODS AND MATERIALS: Patients with intermediate-risk and high-risk localized prostate cancer received MRI-guided high-dose-rate brachytherapy boosts before and after a course of external beam radiotherapy. Using a custom visualization and targeting program, the brachytherapy catheters were placed and adjusted under MRI guidance until satisfactory implant geometry was achieved. Inverse treatment planning was performed using high-resolution T(2)-weighted MRI. RESULTS: Ten brachytherapy procedures were performed on 5 patients. The median percentage of volume receiving 100% of prescribed minimal peripheral dose (V(100)) achieved was 94% (mean, 92%; 95% confidence interval, 89-95%). The urethral V(125) ranged from 0% to 18% (median, 5%), and the rectal V(75) ranged from 0% to 3.1% (median, 0.3%). In all cases, lesions highly suspicious for malignancy could be visualized on the procedural MRI, and extracapsular disease was identified in 2 patients. CONCLUSION: High-dose-rate prostate brachytherapy in a standard 1.5T MRI scanner is feasible and achieves favorable dosimetry within a reasonable period with high-quality image guidance. Although the procedure was well tolerated in the acute setting, additional follow-up is required to determine the long-term safety and efficacy of this approach.

Aged↗

Computational cardiac anatomy using MRI.

Ventricular geometry and fiber orientation may undergo global or local remodeling in cardiac disease. However, there are as yet no mathematical and computational methods for quantifying variation of geometry and fiber orientation or the nature of their remodeling in disease. Toward this goal, a landmark and image intensity-based large deformation diffeomorphic metric mapping (LDDMM) method to transform heart geometry into common coordinates for quantification of shape and form was developed. Two automated landmark placement methods for modeling tissue deformations expected in different cardiac pathologies are presented. The transformations, computed using the combined use of landmarks and image intensities, yields high-registration accuracy of heart anatomies even in the presence of significant variation of cardiac shape and form. Once heart anatomies have been registered, properties of tissue geometry and cardiac fiber orientation in corresponding regions of different hearts may be quantified.

Algorithms↗

Systolic improvement and mechanical resynchronization does not require electrical synchrony in the dilated failing heart with left bundle-branch block.

BACKGROUND: Biventricular (BiV) and left ventricular (LV) pacing similarly augment systolic function in left bundle-branch block (LBBB)-failing hearts despite different electrical activation. We tested whether electrical synchrony is required to achieve mechanical synchronization and functional benefit from pacing. METHODS AND RESULTS: Epicardial mapping, tagged MRI, and hemodynamics were obtained in dogs with LBBB-failing hearts during right atrial, LV, and BiV stimulation. BiV and LV both significantly improved chamber hemodynamics (eg, 25% increase in dP/dt(max) and aortic pulse pressure) compared with atrial pacing-LBBB, and this improvement correlated with mechanical resynchronization. Electrical dispersion, however, decreased 13% with BiV but increased 23% with LV pacing (P<0.01). CONCLUSION: Improved mechanical synchrony and function do not require electrical synchrony. Mechanical coordination plays the dominant role in global systolic improvement with either pacing approach.

Animals↗

Electromechanical mapping with MRI tagging and epicardial sock electrodes.

Methods currently exist for the precise measurement of local three-dimensional myocardial motion noninvasivly with magnetic resonace imaging tagging. From these motion estimates, strain images representing the local deformation of the myocardium can be formed to show local myocardial contraction. These images clearly show the sequence of mechanical events during the activation and relaxation of the heart, making them ideal to visualize abnormalities caused by asynchronous electrical activation or ischemia. Coupled with the near simultaneous mapping of electrical depolarization with a sock electrode array, we can investigate the relationship between electical activity and mechanical function on a local level in the in vivo heart. Registered fiber angle maps can be also be obtained in the same heart with diffusion magnetic resonance imaging to assist in the construction of the electromechanical model of the whole heart.

Electrodes↗

Imaging-based integrative models of the heart: closing the loop between experiment and simulation.

We describe methodologies for: (a) mapping ventricular activation using high-density epicardial electrode arrays; (b) measuring and modelling ventricular geometry and fibre orientation at high spatial resolution using diffusion tensor magnetic resonance imaging (DTMRI); and (c) simulating electrical conduction; using comprehensive data sets collected from individual canine hearts. We demonstrate that computational models based on these experimental data sets yield reasonably accurate reproduction of measured epicardial activation patterns. We believe this ability to electrically map and model individual hearts will lead to enhanced understanding of the relationship between anatomical structure, and electrical conduction in the cardiac ventricles.

Algorithms↗