PubMed Health⌕ Search

Biomedical subjects

Elmar Kotter

Publications and source records attributed to Elmar Kotter.

16 recordsLinked to original sources

MRI and discography in traumatic intervertebral disc lesions.

In this study we evaluated magnetic resonance imaging (MRI) in trauma patients for assessing traumatised adjacent discs of fractured vertebrae before dorsoventral stabilisation. In a prospective study, MRI of 54 discs was performed with a 1.5-T MRI unit. The preoperative MRI with sagittal T1-W-SE and T2-W-TSE was compared to intraoperative discography, which was carried out on both intervertebral discs adjacent to the fractured vertebrae. Signal alterations, morphological changes in the adjacent discs, fractured vertebrae and associated ligament injuries were evaluated. In 47/54 (87%) of the intervertebral discs, the results of both imaging findings were concordant. The discs adjoining vertebral fractures were normal in 18 cases. Regarding the positive concordant imaging findings, MRI and discography revealed traumatised adjacent cranial and caudal discs in 22 discs. In 7 cases, only the cranial adjacent disc was affected. Moreover, 17 cases of intradiscal bleeding, 13 intraosseous herniations into the fractured vertebrae and 20 anuluar tears were visualised in MRI. Associated ligament injuries were detected in 18 cases. Findings were discordant in eight discs. In six discs, MRI was abnormal, demonstrating signal alterations suggestive of positive imaging findings, whereas discography demonstrated no disc injury. MRI failed to detect disc injury in two discs, whereas discography was positive, showing an irregular intradiscal contrast media distribution. MRI, as a non-invasive method for assessing fractures of the thoraco-lumbar spine, may detect traumatised adjacent intervertebral discs. MRI is superior to intraoperative discography. The performance of MRI of the thoraco-lumbar spine is recommended before dorsoventral stabilisation in trauma patients, as it can reveal additional preoperative information such as fractures, disc and associated ligament injuries.

Adolescent↗

Technologies for image distribution in hospitals.

After the establishment of web-based image distribution, three challenges for image distribution can be identified today. Firstly, PACS (picture archiving and communication system) and the distribution of radiological images and reports need to be integrated with the emerging electronic medical record. Secondly, report and image data should be available on mobile devices like PDAs (personal digital assistants) or smartphones in the future. Thirdly, future systems must be available not only to transmit sectional images, but also to allow access to three- and four-dimensional data that are produced by multidetector CT and modern MR scanners.

Computers, Handheld↗

Initial experience with 64-slice cardiac CT: non-invasive visualization of coronary artery bypass grafts.

AIMS: The aim of this study was to evaluate the diagnostic accuracy in the assessment of coronary artery bypass grafts using 64-slice computed tomography (CT) technology. METHODS AND RESULTS: CT coronary angiography was performed for 96 bypasses in 31 patients with suspected coronary artery disease using a Siemens Sensation 64-slice CT-scanner and compared with invasive coronary angiography (ICA). Patients with an irregular or fast heart rate despite beta-blocker administration were not excluded from the study. All bypass grafts and 94% of the distal bypass anastomoses could be visualized by CT, non-evaluable distal arterial anastomoses were either due to clip material or calcification artefacts. Forty-two bypass graft occlusions and three significant stenoses were detected by CT and confirmed by ICA. Two venous grafts were missed and one arterial graft was not evaluable with ICA, but both were clearly depicted by multi-slice CT. One false negative and two false positive CT-findings resulted in a sensitivity of 97.8%, a specificity of 89.3%, a positive predictive value of 90%, and a negative predictive value of 97.7%. CONCLUSION: State-of-the-art 64-slice CT coronary angiography demonstrates high diagnostic accuracy in the assessment of arterial and venous bypass graft stenoses.

Aged↗

Whole-body MRI in the detection of bone marrow infiltration in patients with plasma cell neoplasms in comparison to the radiological skeletal survey.

To compare the diagnostic value of whole-body MRI versus radiological skeletal survey (RSS) in staging patients with plasma cell neoplasms (PCN) and to evaluate the possible therapeutic impact of the replacement of RSS by whole-body MRI. Fifty-four patients with PCN [multiple myeloma (MM), n=47; monoclonal gammopathy of unknown significance (MGUS), n=7] were studied by whole-body MRI and RSS in a monocenter prospective analysis from August 2002 to May 2004. The MRIs were performed using a rolling table platform "AngioSURF" for unlimited field of view with a 1.5-T system (Magnetom Sonata/Maestro Class, Siemens Medical Solutions, Erlangen, Germany). A coronal STIR sequence (TR5500-4230/TE102-94/TI160) was used for imaging of the different body regions, including the head, neck, thorax, abdomen, pelvis and upper and lower extremities. The RSS consisted of eight different projections of the axial and appendicular skeleton. In 41/54 (74%) patients, the results of the whole-body MRI and RSS were concordant. In 11/54 (20%) patients, both imaging techniques were negative. Bone involvement was observed in 30/54 (55%) patients; however, whole-body MRI revealed this more extensively than the RSS in 27/30 (90%) patients with concordant positive imaging findings. In 3/30 (10%) patients, both imaging techniques demonstrated a similar extent of bone marrow infiltration. In 10/54 (19%) patients, the whole-body MRI was superior to RSS in detecting bone marrow infiltration, whereas the RSS was negative. In 3/54 (6%) patients, the RSS was proven to be false positive by the clinical course, whereas the whole-body MRI was truly negative. Whole-body MRI is a fast and highly effective method for staging PCN patients by the use of a rolling table platform. Moreover, it is more sensitive and specific than RSS and reveals bone marrow infiltration and extensive disease more reliably. Therefore, whole-body MRI should be performed as an additional method of exactly staging PCN patients and - with more data in the field - may even prove to be an alternate and more sensitive staging procedure than RSS in PCN patients.

Adult↗

MR findings in a rare case of sclerosing mesenteritis of the mesocolon.

Sclerosing mesenteritis is a rare, usually benign disorder of the mesentery. Depending on the predominant tissue component (inflammation, fat, or fibrosis), it is known as mesenteric panniculitis or retractile mesenteritis. We present a rare case of retractile mesenteritis of the mesocolon as a cause of severe abdominal pain. US, CT, and MRI were the imaging modalities used. We emphasize the MR finding of a fibrous capsula in retractile mesenteritis, as this is to our knowledge the first study to describe this entity. This finding may be valuable for establishing a diagnosis of sclerosing mesenteritis, as well as for differentiating this disease from other mesenteric diseases.

Adult↗

Pulmonary manifestations of wegener granulomatosis: CT findings in 57 patients and a review of the literature.

Wegener granulomatosis is a multisystem disease of unknown cause characterized by a necrotizing granulomatous vasculitis. In comparison to other vasculitides, the lung is the most common organ involved in wegener granulomatosis presenting with a very aggressive airways pathology and chronic relapsing course. Chest radiographs fail to describe the pattern and distribution of thoracic pathology sufficiently, and CT has shown to be more sensitive for detecting lung involvement. We present the CT findings of 57 patients with wegener granulomatosis and a review of the literature.

Adult↗

Detectability of liver metastases in malignant melanoma: prospective comparison of magnetic resonance imaging and positron emission tomography.

PURPOSE: We evaluated the diagnostic accuracy of magnetic resonance imaging (MRI) and positron emission tomography (PET) for detection of liver metastases in malignant melanoma. MATERIAL AND METHODS: Thirty-five patients with 39 combined unenhanced MRI and fluorine-18 deoxyglucose (F-18 FDG) PET scans were prospectively studied. In discordant imaging findings final diagnosis was proven by clinical follow-up >6 months and demonstration of progressive liver metastases by at least one imaging method. Sensitivities and specificities were compared and the influence of lesion size and melanin content on diagnostic accuracy was determined. RESULTS: MRI and PET were concordantly negative for presence and number of liver metastases in 28 patients and positive in four patients. PET and MRI were false positive in one patient each. In one patient MRI showed a single metastases not seen by PET and in one patient MRI demonstrated more metastases at the first examination. In follow-up investigations MRI revealed more metastases than PET in both patients. The sensitivities for lesion detection were 47% (16/34) for PET and 100% for MRI. Lesion detectability by PET was related to lesion size (P < 0.0001) but not to melanin content. CONCLUSION: MRI is more sensitive in the detection of liver metastases in patients with malignant melanoma. Small lesions are easily missed by PET, while melanin content does not influence detectability by PET.

Adult↗

CT in acute perforated sigmoid diverticulitis.

BACKGROUND: To assess the value of computed tomography (CT) in patients with acute perforated sigmoid diverticulitis in correlation with the Hinchey classification of perforated diverticular disease. METHODS: Thirty patients with acute perforated sigmoid diverticulitis underwent computed tomography prior to surgery. Computed tomography scans were compared with the surgical and histopathological reports, utilizing the Hinchey classification. RESULTS: In 28 of the 30 (93%) patients examined, the Hinchey stage was correctly determined by means of computed tomography. One patient with Hinchey stage IV was falsely classified as Hinchey stage III, and one patient with Hinchey stage III as Hinchey stage II. Computed tomography revealed 12 out of 14 (86%) patients with perforation sites and 3 out of 3 (100%) patients with contained perforation. In one of 17 (6%) patients with surgically or histopathologically proven perforation or contained perforation, a bowel wall discontinuity was revealed by computed tomography. In 6 of the 17 (35%) patients with surgical or histopathological perforation or contained perforation, extraluminal contrast material was detected by computed tomography. CONCLUSIONS: Computed tomography is a valuable imaging tool for determining the degree of acute perforated sigmoid diverticulitis, by means of which patients can be stratified according to the severity of the disease; furthermore, this tool is of assistance in surgical planning.

Acute Disease↗

Asymptomatic esophago-pleural fistula presenting 35 years after pneumonectomy for tuberculosis.

Postpneumonectomy esophago-pleural fistula (EPF) is rare and potentially life-threatening. It is mainly caused by surgical injury, local cancer recurrence, and chronic inflammation or infection. Patients with postpneumonectomy EPF usually present with empyema. We report a case of a clinically asymptomatic esophago-pleural fistula, diagnosed accidentally in a 64-year-old woman more than 30 years after right lobe pneumonectomy due to tuberculosis. Contrast-enhanced CT, chest radiography, and esophagogramm were the imaging modalities used together with esophagoscopy in diagnosing the EPF; however, contrast-enhanced CT in combination with oral given contrast-media is the first imaging technique of choice to evaluate esophago-pleural fistula.

Contrast Media↗

High-resolution CT imaging of the lung for patients with primary Sjogren's syndrome.

PURPOSE: To assess pulmonary abnormalities in patients with primary Sjogren's syndrome (PSS) using high-resolution computed tomography (HRCT). MATERIAL AND METHODS: The HRCT scans of 24 patients with the diagnosis PSS were retrospectively reviewed regarding the presence, extension and distribution of 16 pathological findings. RESULTS: Nineteen patients (79.2%) showed pathological findings and in five patients (21.8%) the HRCT scan was judged to be normal. A predominance of abnormalities in the lower lobes and subpleural areas was detected. The following pathologies were found: bronchiectasis, thin-walled cysts and small pulmonary nodules (46.2%), ground-glass attenuation and emphysema (37.8%), interlobular-septal thickening (29.4%), honeycombing (25.2%), bronchial wall thickening, tree-in-bud pattern (21.0%), mosaic perfusion (16.8%), architectural distortion (12.6%). Airspace consolidation, air trapping, large nodules (10-30mm) and masses (>30mm), mediastinal lymph node enlargement (>15mm) and free pleural fluid were seen each in 4.2%. In 7 of the 11 patients with thin-walled cysts areas of ground-glass attenuation were detected. CONCLUSION: HRCT seems is contributive to the characterization of the wide variety of lung abnormalities in PSS. Airway disease alone or in association with the presence of varying degrees of interstitial disease represents the main findings in accordance with earlier reports. Unexpectedly, almost half of the patients had thin-walled cysts on the HRCT scans, which etiology is unclear but could be associated with areas of ground-glass attenuation indicating LIP.

Adult↗

Radiological findings in Boerhaave's syndrome.

The aim was to define the diagnostic value of chest radiography, esophagography, and computed tomography (CT) in patients with Boerhaave's syndrome. CT findings in 14 patients (11 male, 3 female; mean age: 60 years; median age: 66 years; age range: 36-78 years) with spontaneous esophageal perforation were retrospectively reviewed and compared to those of esophagography ( n=11) and chest radiography ( n=14). In six patients unenhanced CT scans were available; in ten patients (2/10 patients had an unenhanced CT before) a contrast-enhanced CT was performed as an emergency investigation. In 5/14 patients additional oral contrast medium was given. Chest radiography revealed pleural effusions in 9/14 and infiltrates in 9/14 patients. Pneumothorax and pneumopericardium were observed in two patients each. Pneumomediastinum was seen in three patients. Two chest radiographs were normal. Esophagography performed in 11 patients demonstrated contrast medium extravasation at a supradiaphragmatic level in seven patients, indicating esophageal perforation with esophagopleural fistula, and a submucosal contrast medium collection in four cases. Unenhanced CT scans revealed four intramural hematomas with typical localization. Unenhanced and contrast-enhanced CT demonstrated periesophageal air collections indicating esophageal perforation in all patients. Pleural effusions were seen in 11/14 and infiltrates in 8/14 patients. Contrast medium extravasation was observed in 5/14 patients, whereas a thickening of the esophageal wall was depicted in 11/14 patients. Periaortic air tracks ( n=7), pneumothorax ( n=3), pneumomediastinum ( n=6), and mediastinal fluid collections ( n=7) were depicted in CT. By demonstrating periesophageal air tracks suggestive of esophageal perforation, CT reveals the decisive criteria for diagnosing Boerhaave's syndrome and should therefore be performed in the diagnostic work-up of patients in whom this syndrome is part of the differential diagnosis.

Journal Article↗

Computed tomography in gastrointestinal stromal tumors.

The aim of this study was to define the imaging characteristics of primary and recurrent gastrointestinal stromal tumors (GIST) in computed tomography with respect to the tumor size. Computed tomography was performed in 35 patients with histologically confirmed gastrointestinal stromal tumors and analyzed retrospectively by two experienced and independent radiologist. The following morphologic tumor characteristics of primary ( n=20) and ( n=16) recurrent tumors were evaluated according to tumor size, shape, homogeneity, density compared with liver, contrast enhancement, presence of calcifications, ulcerations, fistula or distant metastases and the anatomical relationship to the intestinal wall, and the infiltration of adjacent visceral organs. Small GIST (<5 cm) showed a sharp tumor margin with homogeneous density and structure on unenhanced and contrast-enhanced images, and were characterized by an intraluminal tumor growth. Intermediate sized GIST (>5-10 cm) demonstrated an irregular shape, inhomogeneous density on unenhanced and contrast-enhanced images, a combined intra- and extraluminal tumor growth with aggressive findings, and infiltration of adjacent organs in 9 primary diagnosed and 2 recurrent tumors. Large GIST (>10 cm), which were observed in 8 primary tumors and 11 recurrent tumors, showed an irregular margin with inhomogeneous density and aggressive findings, and were characterized by signs of malignancy such as distant and peritoneal metastases. Small recurrent tumors had a similar appearance as compared with large primary tumors. Computed tomography gives additional information with respect to the relationship of gastrointestinal stromal tumor to the gastrointestinal wall and surrounding organs, and it detects distant metastasis. Primary and recurrent GIST demonstrate characteristic CT imaging features which are related to tumor size. Aggressive findings and signs of malignancy are found in larger tumors and in recurrent disease. Computed tomography is useful in detection and characterization of primary and recurrent tumors with regard to tumor growth pattern, tumor size, and varied appearances of gastrointestinal stromal tumors, and indirectly gives hints regarding dignity and therefore prognostic outcome.

Female↗

Amorphous silicon, flat-panel, x-ray detector versus storage phosphor-based computed radiography: contrast-detail phantom study at different tube voltages and detector entrance doses.

RATIONALE AND OBJECTIVES: Evaluation of the contrast-detail performance of an active-matrix flat-panel x-ray detector in comparison with a storage phosphor system with special regard to the potential of dose reduction. METHODS: A digital x-ray detector based on cesium iodide (CsI) and amorphous silicon (a-Si) technology was compared with a fifth-generation storage phosphor system. A lucite plate with 36 drilled holes of varying diameters and depths was used as contrast-detail phantom. At 45 kVp, 70 kVp, and 113 kVp, images at 8 different detector entrance doses ranging between 0.3 microGy and 40 microGy were obtained. On soft-copy displays, 3 masked observers evaluated the detectability of each aperture in each image according to a 5-point scale. The mean sum scores of corresponding images were compared. RESULTS: For all tube voltages and detector entrance doses, the images obtained with the CsI/a-Si detector resulted in better observer contrast-detail performance as compared with the images of the storage phosphor system. The CsI/a-Si system allowed a calculated dose reduction of 39% at 45 kVp, 68% at 70 kVp, and 81% at 113 kVp as compared with the storage phosphor system, without loss of contrast-detail detectability. CONCLUSIONS: Under the conditions of the chosen experimental design, the CsI/a-Si system provided a superior contrast-detail performance as compared with the storage phosphor system. The potential of dose reduction increased with rising tube voltage.

Cesium↗

Comparison of the detectability of high- and low-contrast details on a TFT screen and a CRT screen designed for radiologic diagnosis.

RATIONALE AND OBJECTIVES: To evaluate the detection rate of fine details of a new thin-film transistor (TFT) grayscale monitor designed for radiologic diagnosis, compared with a type of cathode ray tube (CRT) screen used routinely for diagnostic radiology. METHODS: Fifteen radiographs of a statistical phantom presenting low- and high-contrast details were obtained and read out with an Agfa ADC compact storage phosphor system. Each radiograph presented 60 high-density (high-contrast) and 60 low-density (low-contrast) test bodies. Approximately half the test bodies contained holes with different diameters. Observers were asked to detect the presence or absence of a hole in the test body on a 5-point confidence range. The total of 1800 test bodies was reviewed by 5 radiologists on the TFT monitor (20.8 inches; 1536 x 2048 pixels; maximum luminance, 650 cd/m2; contrast, 600:1) and the CRT monitor (21 inches; P45 Phosphor; 2048 x 2560 pixels operated at 1728 x 2304 pixels; maximum luminance, 600 cd/m2; contrast, 300:1). The data were analyzed by receiver-operator characteristic analysis. RESULTS: For high-contrast details, the mean area under the curve rated 0.9336 for the TFT monitor and 0.9312 for the CRT monitor. For low-contrast details, the mean area under the curve rated 0.9189 for the TFT monitor and 0.9224 for the CRT monitor. At P <or= 0.05, no statistically significant difference could be detected between the 2 observational modalities for both (holes in high- and low-contrast disks) types of artifacts. CONCLUSIONS: The TFT screen performs as well as CRT monitors for the detection of fine details in both high- and low-contrast environments. Further studies with images derived from clinical routine are necessary before safely using TFT monitors in clinical practice.

Phantoms, Imaging↗

Comparison of reconstruction intervals in routine ECG-pulsed 64-row-MSCT coronary angiography in frequency controlled patients.

PURPOSE: In light of the increasing use and acceptance of multislice computed tomography (MSCT) coronary angiography it was the purpose of this study to compare reconstruction intervals used in a routine ECG-pulsed MSCT coronary artery angiography setting with frequency controlled patients. METHODS: Examinations were performed on a Siemens Somatom Sensation 64 scanner with a total of 110 ml of contrast agent and ECG pulsing (interval from 40% to 70%) after oral application of a beta-blocker if the heart rate was higher than 65 bpm. All human subjects were referred for the evaluation of suspected coronary artery disease. Coronary artery segments were evaluated by two experienced radiologists in a consensus reading. A ranking of diagnostic image quality (from 1 (no evaluation possible) to 5 (excellent image quality)) was statistically evaluated by Wilcoxon Signed Rank Test. RESULTS: In 45 patients (30 male, 15 female, age 63.8 +/- 12.1 years) we detected a significant advantage of the 60% reconstruction interval over 40%, 50%, and 70% (for each p < 0.05). In cases of sudden arrhythmia or movement during the scan, additional reconstruction intervals within the ECG-pulsed reconstruction intervals remained necessary for diagnosis. CONCLUSION: In a routine diagnostic setting with frequency controlled patients and ECG pulsing the 60% reconstruction interval can be considered superior for the initial diagnosis in 64-row multislice computed tomography coronary angiography. However, further information can be derived from various reconstruction intervals such as 40% and 70%.

Adult↗

Sinonasal computed tomography in patients with Wegener's granulomatosis.

The goal of this study was to describe pathologies of sinonasal CT in patients with Wegener's granulomatosis. Between 1993 and 2004, sinonasal CT was performed in 28 patients (15 male, 13 female) with Wegener's granulomatosis. The following imaging findings were assessed on the CT scans: mucosal thickening, subtotal opacification, air-fluid level, bony destruction, sclerosing osteitis, bony thickening, orbital mass, and saddle nose deformity. Of the 28 patients, 61% showed mucosal thickening in the nasal cavity and 75% in the paranasal sinuses. A subtotal opacification of the paranasal sinuses was detected in 25%, and of the mastoid cells in 7% of patients. Fifty-seven percent of patients had bony destruction of the nasal cavity, and 54% of the paranasal sinuses. CT revealed sclerosing osteitis of the paranasal sinuses in 21%, and of the mastoid cells in 18% of patients. Bony thickening of the paranasal sinuses was detected in 18%, and of the mastoid cells in 14% of patients. With respect to all imaging findings, the maxillary sinuses were the most frequently affected paranasal sinuses. The authors conclude that the following sinonasal CT findings are observed in patients with Wegener's granulomatosis: (1) bony destruction, mainly of the nasal cavity, maxillary sinuses, and mastoid cells; (2) sclerosing osteitis, mainly of the maxillary sinuses and mastoid cells; (3) bony thickening, mainly of the maxillary sinuses and mastoid cells; and (4) mucosal thickening, mainly of the maxillary sinuses. These findings are, however, nonspecific and should be combined with other clinicopathologic and laboratory studies to confirm the diagnosis of Wegener's granulomatosis.

Adult↗