Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples.

In this work the third generation of flow injection analysis, that is, the so-called micro-lab-on-valve (microLOV) approach, is proposed for the first time for the separation, preconcentration, and monitoring of metalloids as hyphenated with atomic fluorescence spectrometry (AFS). This was made feasible by interfacing the micromachined LOV-module with AFS by a multisyringe flowing stream network for on-line postcolumn derivatization of the eluate aimed at generation of hydride species. The potential of this new hyphenated technique for environmental assays was ascertained via determination of ultratrace level concentrations of total inorganic arsenic in freshwater. Employing quantitative preoxidation of As(III) to As(V) in the samples by means of permanganate, the method involves preconcentration of arsenate at pH 10 on a renewable anion exchanger, namely, Q-Sepharose, packed in a LOV microcolumn. The analyte species is afterward stripped out and concurrently prereduced by a 300 microL eluent plug containing 6 mol L(-)1 HCl and 10% KI. The eluate is downstream merged with a metered volume of sodium tetrahydroborate (0.3% w/v) for generation of arsine, which is subsequently quantified by AFS. The flow system facilitates on-column reduction of the retained arsenic with no need for application of programmable stopped flow. Yet, the high concentration of reductant and extreme pH conditions for elution hinder the sorbent to be reused due to gradual deactivation of the functional moieties, so that maximum benefit can be taken from the application of the bead renewable strategy. The proposed procedure is characterized by a high tolerance to metal species and interfering hydride-forming elements. In fact, ratios of Se(IV) to As < or = 5000 and Sb(V) to As < or = 500 are tolerated at the 10% interference level. Under the optimized experimental conditions, a detection limit (3sigma) of 0.02 ng mL(-1) As, a dynamic linear range of 0.05-2.0 ng mL(-1) As (by tailoring the AFS gain), an enrichment factor of 8.8 for arsenate, and a precision better than 6.0% at the 0.1 ng mL-1 level were obtained for the bead-injection mode whenever the loading sample volume was affixed at 3.0 mL. The reliability and accuracy of the automated procedure was ascertained by determining total inorganic arsenic in both spiked environmental waters and certified reference materials of variable matrix complexity (TMDA-54.3 and ERM-CA010) at the low ng mL(-1) level. No significant differences were found between the experimental results and the certified values at a significance level of 0.05.

Journal Article↗

Development of a simple extraction cell with bi-directional continuous flow coupled on-line to ICP-MS for assessment of elemental associations in solid samples.

A continuous-flow system comprising a novel, custom-built extraction module and hyphenated with inductively coupled plasma-mass spectrometric (ICP-MS) detection is proposed for assessing metal mobilities and geochemical associations in soil compartments as based on using the three step BCR (now the Measurements and Testing Programme of the European Commission) sequential extraction scheme. Employing a peristaltic pump as liquid driver, alternate directional flows of the extractants are used to overcome compression of the solid particles within the extraction unit to ensure a steady partitioning flow rate and thus to maintain constant operationally defined extraction conditions. The proposed flow set-up is proven to allow for trouble-free handling of soil samples up to 1 g and flow rates < or =10 mL min(-1). The miniaturized extraction system was coupled to ICP-MS through a flow injection interface in order to discretely introduce appropriate extract volumes to the detector at a given time and with a given dilution factor. The proposed hyphenated method demonstrates excellent performance for on-line monitoring of major and trace elements (Ca, Mn, Fe, Ni, Pb, Zn and Cd) released when applying the various extracting reagents as addressed in the BCR scheme, that is, 0.11 M CH(3)COOH, 0.1 NH(2)OH.HCl and 30% H(2)O(2), even when a well recognized matrix-sensitive detector, such as ICP-MS, is used. As a result of the enhanced temporal resolution of the ongoing extraction, insights into the breaking down of phases and into the kinetics of the metal release are obtained. With the simultaneous multielement detection capability of ICP-MS, the dynamic fractionation system presents itself as an efficient front-end for evaluation of actual elemental association by interelement comparison of metals leached concurrently during the extraction time. Thus, the intimate elemental association between Cd and Zn in contaminated soils could be assessed.

Chemical Fractionation↗

Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

Journal Article↗

On-line dynamic extraction and automated determination of readily bioavailable hexavalent chromium in solid substrates using micro-sequential injection bead-injection lab-on-valve hyphenated with electrothermal atomic absorption spectrometry.

A novel and miniaturized micro-sequential injection bead-injection lab-on-valve (microSI-BI-LOV) fractionation system was developed for on-line microcolumn soil extraction under simulated environmental scenarios and accurate monitoring of the content of easily mobilisable hexavalent chromium in soil environments at the sub-low parts-per-million level. The flow system integrates dynamic leaching of hexavalent chromium using deionized water as recommended by the German Standard DIN 38414-S4 method; on-line pH adjustment of the extract by a 0.01 mol L(-1) Tris-HNO(3) buffer solution; isolation of the chromate leached from the matrix constituents onto a Q Sepharose strong anion-exchanger freshly packed into the microconduits of the microSI-assembly; air-segmented elution of the sorbed species by a 40 microL plug of 0.5 mol L(-1) NH(4)NO(3) (pH 8) eluent; and detection by electrothermal atomic absorption spectrometry (ETAAS). The effect of simulated acidic rain on the accessibility of chromate forms for plant uptake was also investigated. The proposed approach offers several advantages over conventional speciation/fractionation protocols in the batch mode, including immediate separation with concomitant preconcentration of the released chromate, minimization of Cr(vi) to Cr(iii) interconversion risks, enhanced accuracy, and non-existence of re-adsorption/re-distribution problems along with a detailed pattern of the kinetics of the leaching process. The reliability of the proposed method was evaluated via spiking of a moderately polluted agricultural soil material (San Joaquin Soil-Baseline Trace Element Concentrations) with water-soluble Cr(vi) salts at different concentration levels. The potential of the microSI-BI-LOV set-up with renewable surfaces for flame-AAS determination of high levels of readily bioavailable chromate in contaminated soils is also addressed.

Biological Availability↗

Universal approach for selective trace metal determinations via sequential injection-bead injection-lab-on-valve using renewable hydrophobic bead surfaces as reagent carriers.

A new concept is presented for selective and sensitive determination of trace metals via electrothermal atomic absorption spectrometry based on the principle of bead injection (BI) with renewable reversed-phase surfaces in a sequential injection-lab-on-valve (SI-LOV) mode. The methodology involves the use of poly(styrene-divinylbenzene) beads containing pendant octadecyl moieties (C18-PS/DVB), which are preimpregnated with a selective organic metal chelating agent prior to the automatic manipulation of the beads in the microbore conduits of the LOV unit. By adapting this approach, the immobilization of the most suitable chelating agent can be effected irrespective of the kinetics involved, optimal reaction conditions can be used for implementing the chelating reaction of the target metal analyte with the immobilized re-agent, and an added degree of freedom is offered in selecting the most favorable elution mode in order to attain the highest sensitivity. The potential of the SI-BI-LOV scheme is demonstrated by taking Cr(VI) as a model analyte, using a 1,5-diphenylcarbazide (DPC)-loaded bead column as the active microzone. As this reaction requires the use of high acidity, it is also shown that the bead material exhibits excellent chemical stability at low pH values. On-line pH sample adjustment prevents alteration of the original distribution of chromium species while ensuring fast rates for the DPC-Cr(VI) reaction. The proposed procedure was successfully applied to the determination of trace levels of Cr(VI) in natural waters containing high levels of dissolved salts (such as seawater and hard tap water) without requiring any dilution step. Method validation was performed by determination of total chromium in an NIST standard reference material (NIST 1640, natural water) after Cr(III) oxidation, and the results were in good agreement with the certified value.

Journal Article↗

Automated sequential injection-microcolumn approach with on-line flame atomic absorption spectrometric detection for implementing metal fractionation schemes of homogeneous and nonhomogeneous solid samples of environmental interest.

An automated sequential injection (SI) system incorporating a dual-conical microcolumn is proposed as a versatile approach for the accommodation of both single and sequential extraction schemes for metal fractionation of solid samples of environmental concern. Coupled to flame atomic absorption spectrometric detection and used for the determination of Cu as a model analyte, the potentials of this novel hyphenated approach are demonstrated by the ability of handling up to a 300 mg sample of a nonhomogeneous sewage amended soil (viz., CRM 483). The three steps of the endorsed Standards, Measurements, and Testing sequential extraction method have been also performed in a dynamic fashion and critically compared with the conventional batchwise protocols. The ecotoxicological relevance of the data provided by both methods with different operationally defined conditions is thoroughly discussed. As compared to traditional batch systems, the developed SI assembly offers minimal risks of sample contamination, the absence of metal re-distribution/readsorption, and dramatic saving of operational times (from 16 h to 40-80 min per partitioning step). It readily facilitates the accurate manipulation of the extracting reagents into the flow network and the minute, well-defined injection of the desired leachate volume into the detector. Moreover, highly time-resolved information on the ongoing extraction is given, which is particularly relevant for monitoring fast leaching kinetics, such as those involving strong chelating agents. On-line and off-line (for Cu, Pb, and Zn) single extraction schemes are also proven to constitute attractive alternatives for fast screening of metal pollution in solid samples and for predicting the current, rather than the potential, element bioavailability by the assessment of the readily mobilizable metal forms.

Journal Article↗

Use of flow injection and sequential injection analysis schemes for the determination of trace-level concentrations of metals in complex matrices by ETAAS and ICPMS.

Despite their excellent analytical chemical capacities for determination of low levels of metal species, electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry often require suitable pretreatment (separation and preconcentration) of the sample material to facilitate the desired sensitivity and selectivity of measurement. Such pretreatment schemes are advantageously performed in flow injection (FI) or sequential injection (SI) manifolds, where all unit operations can be effected on-line and under enclosed and strictly controlled conditions. Various separation/preconcentration procedures are feasible, such as liquid-liquid extraction (possibly including back extraction), (co)precipitation with collection in knotted coils, adsorption on hydrophilic or hydrophobic reactors, hydride generation, or the use of ion-exchange/chelating packed columns. After describing the particulars and characteristics of FI and SI, we present, via selected examples, various separation/preconcentration FI/SI schemes for the determination of trace levels of metals, with particular emphasis on the use of the novel extension of FI/SI, that is, the so-called lab-on-valve concept.

Environmental Monitoring↗