Spectrophotometric determination of trace arsenic in water samples using a nanoparticle of ethyl violet with a molybdate-iodine tetrachloride complex as a probe for molybdoarsenate.

A new spectrophotometric method was developed for the determination of low ppb levels of arsenic in water. We found that Ethyl Violet with molybdate-iodine tetrachloride complex forms nanoparticles under acidic conditions, which provide a sensitive probe for molybdoarsenate. The nanoparticles form stable particles with a diameter micrometers in size in the presence of heteropolyacid, and the resulting particles give a purple color to the apparently homogeneous solution, the intensity of which depends on the arsenic concentration. The nanoparticle itself is unstable due to conversion of the dye to a colorless carbinol species under acidic conditions without heteropolyacid. Although triphenylmethane dyes have been the subject of a number of investigations, there do not appear to be any reports on the dye particles for trace determination. The calibration curve is linear up to 20 microg L-1 arsenic, and the detection limit is 0.5 microg L-1 (6.6 x 10(-9) mol L-1). The coefficient of variation for spectrophotometry at 10 microg L-1 is 5.8% (n = 8). Furthermore, it is possible to detect concentrations as low as 1 microg L-1 arsenic visually using this method. The interferences from phosphorus and silica were eliminated using an anion exchange column and sodium fluoride as a masking agent, respectively. The proposed method has been successfully applied to water samples in abandoned mine water, groundwater, and river water. There was good agreement between the results obtained by the proposed method and those by hydride generation atomic absorption spectrometry. Since this method is specific for As(V), it is applicable to the speciation of arsenic oxidation states. Our method has enormous practical potential for simple and field detection of arsenic, requiring no complex apparatus or skilled laboratory support.

Arsenates↗

Spectrophotometric determination of arsenic in water samples based on micro particle formation of ethyl violet-molybdoarsenate.

In this study, a simple and sensitive method for the determination of arsenic in water samples was developed. The method is based on the formation of micro particles of Ethyl Violet and molybdoarsenate, which gives an apparently homogeneous blue color to the solution. The absorption of the excess dye gradually decreases due to its conversion to a colorless carbinol species under strongly acidic conditions. Consequently, the sufficiently low reagent blank enables the spectrophotometric determination of arsenic with the detection limit of 4 microg l(-1). The coefficient of variation for the spectrophotometry at 50 microg l(-1) was 3.5% (n = 5). Furthermore, it is possible to detect concentrations as low as 10 microg l(-1) of arsenic visually. Our method will be useful as a simple, rapid, and cost-effective field test of arsenic, requiring no complex apparatus or skilled laboratory support.

Journal Article↗

Separation of V(V)-4-(2-pyridylazo)resorcinolato complex from a large excess reagent using an ODS cartridge for high-performance liquid chromatography.

A selective off-line preconcentration technique for the V(V) complex with 4-(2-pyridylazo)resorcinol has been developed and successfully applied to the determination of V(V) in an air-borne sample. The target complex was separated from excess reagent using an ODS cartridge and water as the eluent. The complex was then concentrated on another ODS cartridge using tetrabutylammonium bromide and eluted with methanol; the eluate was applied to a one-drop concentration/HPLC. A detection limit as low as (6.05 +/- 0.82)x 10(-11) M (5 ppt) was achieved.

Journal Article↗

Determination of trace silica in highly purified water based on delayed quenching of Rhodamine B through nanoparticle formation with molybdosilicate.

The development of a highly sensitive analytical method for trace silica is an urgent necessity for the real-time monitoring of highly purified water used in the semiconductor industry. However, there are no reports of a simple yet sensitive method for the determination of trace silica. Here we describe the delayed quenching phenomenon of Rhodamine B cation caused by nanoparticle formation with molybdosilicate ions in aqueous solution and its application to the one-step determination of trace silica at ppt to low ppb levels. We found that the quenching takes place over several minutes and the quenching time is dependent on the concentration of silica. The measurements made by a dynamic light scattering particle size analyzer indicated that the diameter of the particles were at nanometer levels. The detection limit was found to be 34 ng dm(-3) Si (1.2 x 10(-9) mol dm(-3)). The average quenching time for 1 microg dm(-3) was 239 s with an RSD of 2.2% (n= 7). The proposed method has been successfully applied to distilled and highly purified water samples. There was good agreement between the results obtained by the proposed method and those by ICP-three dimensions quadrupole MS/MS with 11-fold evaporation concentration. The main point of this method is that in the trace determination of silica, the signal is larger at lower concentrations. The advantages of the proposed method are that it can be used as real-time monitoring for trace silica in highly purified water, and will be a great aid to industries in which the quality control of water is crucial.

Journal Article↗

Development of visual analytical methods for trace determination.

In this paper our recent progress in the field of simple analytical methods is reviewed, with particular focus on the development of rapid, inexpensive, yet sensitive techniques to visualize trace elements of medical, industrial, and environmental importance. Our objective is to solve long-standing practical problems in these fields. We have repeatedly shown that visual perception is remarkably sensitive when used with our new techniques. The applicability of the proposed methods to real samples is also discussed. Making measurements visually is a method free from machinery malfunctions and serves as a simple and sensitive analytical technique, avoiding all of the practical disadvantages associated with sophisticated instrumentation as well as tedious procedures.