PubMed Health⌕ Search

Biomedical subjects

Emma Thomas

Publications and source records attributed to Emma Thomas.

4 recordsLinked to original sources

Esophagus sparing with IMRT in lung tumor irradiation: an EUD-based optimization technique.

PURPOSE: The aim of this study was to evaluate (1) the use of generalized equivalent uniform dose (gEUD) to optimize dose escalation of lung tumors when the esophagus overlaps the planning target volume (PTV) and (2) the potential benefit of further dose escalation in only the part of the PTV that does not overlap the esophagus. METHODS AND MATERIALS: The treatment-planning computed tomography (CT) scans of patients with primary lung tumors located in different regions of the left and right lung were used for the optimization of beamlet intensity modulated radiation therapy (IMRT) plans. In all cases, the PTV overlapped part of the esophagus. The dose in the PTV was maximized according to 7 different primary cost functions: 2 plans that made use of mean dose (MD) (the reference plan, in which the 95% isodose surface covered the PTV and a second plan that had no constraint on the minimum isodose), 3 plans based on maximizing gEUD for the whole PTV with ever increasing assumptions for tumor aggressiveness, and 2 plans that used different gEUD values in 2 simultaneous, overlapping target volumes (the whole PTV and the PTV minus esophagus). Beam arrangements and NTCP-based costlets for the organs at risk (OARs) were kept identical to the original conformal plan for each case. Regardless of optimization method, the relative ranking of the resulting plans was evaluated in terms of the absence of cold spots within the PTV and the final gEUD computed for the whole PTV. RESULTS: Because the MD-optimized plans lacked a constraint on minimum PTV coverage, they resulted in cold spots that affected approximately 5% of the PTV volume. When optimizing over the whole PTV volume, gEUD-optimized plans resulted in higher equivalent uniform PTV doses than did the reference plan while still maintaining normal-tissue constraints. However, only under the assumption of extremely aggressive tumors could cold spots in the PTV be avoided. Generally, high-level overall results are obtained when optimization in the whole PTV is also associated with a second simultaneous optimization in the PTV minus overlapping portions of the esophagus. CONCLUSIONS: Intensity modulated radiation therapy optimizations that utilize gEUD-based cost functions for the PTV and NTCP-based constraints for the OARs result in increased doses to large portions of the PTV in cases where the PTV overlaps the esophagus, while still maintaining (and confining to the overlap region) minimum dose coverage equivalent to the homogeneous PTV optimization cases.

Carcinoma, Non-Small-Cell Lung↗

Benefit of using biologic parameters (EUD and NTCP) in IMRT optimization for treatment of intrahepatic tumors.

PURPOSE: To investigate whether intensity-modulated radiotherapy (IMRT), optimized using the generalized equivalent uniform dose (gEUD) and normal tissue complication probability (NTCP) models, can increase the safe dose to intrahepatic tumors compared with three-dimensional conformal RT (3D-CRT). A secondary objective was to investigate the optimal beam arrangement for liver IMRT plans. METHODS AND MATERIALS: Planning CT data of 15 patients with intrahepatic tumors, previously treated with 3D-CRT, were used as input. The dose delivered using 3D-CRT had been limited either by tolerance of adjacent organs, which were close to, or overlapped with, the planning target volume (PTV; overlap cases, n = 8), or liver toxicity (nonoverlap, n = 7). IMRT plans were created using the gEUD to maximize the dose across the PTV and the NTCP to maintain the organ-at-risk toxicity to that of the conformal plan. Increased heterogeneity was allowed across the PTV in overlap cases, without compromising the minimal PTV dose of the conformal plan and restricting the maximal dose to within 110% of the mean. Three different beam arrangements were used for each case: seven-field equidistant axial, six-field noncoplanar (predominantly right-sided beams), and a reproduction of the conformal gantry angles. gEUDs were also computed and used for evaluation of the plans (regardless of planning technique) to reflect the response of both high- and low-grade tumors. The IMRT plan that allowed the greatest gEUD across the PTV was used in the comparison with the 3D-CRT plan. RESULTS: The use of IMRT significantly increased the maximal gEUD achievable across the PTV compared with the 3D-CRT plans. This was the case for the assumptions of both high- and low-grade tumors, irrespective of the tumor position within the liver. The mean gEUD increase was 11 Gy (high grade) and 18.0 Gy (low grade) for overlap cases (p = 0.001 and p = 0.003, respectively) and 10 Gy for nonoverlap cases (p = 0.020). When comparing the IMRT beam arrangements, gEUDs were considered equivalent if they differed by less than one fraction (1.5 Gy). In overlap cases (n = 8), an equivalent "best" gEUD value was obtained in 3, 5, and 7 cases for the original conformal angle, seven-field axial, and six-field noncoplanar plan, respectively. The corresponding results were 5, 2, and 3 in the cases without an overlap (n = 7). CONCLUSION: We have successfully used mathematical/biologic models directly as cost functions within the optimizing process to produce IMRT plans that maximize the gEUD while maintaining compliance with a well-defined protocol for the treatment of intrahepatic cancer. For both PTV-organ-at-risk overlap and nonoverlap situations, IMRT has the capacity to improve the maximal dose achievable across the PTV, expressed in terms of the gEUD. The use of multiple noncoplanar beams appears to confer an advantage over fewer beams in cases with PTV-organ-at-risk overlap. When liver toxicity is the dose-limiting factor, high gEUD values are obtained most frequently when the field arrangement is chosen to provide the shortest possible transhepatic path length.

Algorithms↗

The role of endoscopic ultrasound (EUS) in planning radiotherapy target volumes for oesophageal cancer.

Computed tomography (CT) scanning is the main imaging modality utilised for planning radical oesophageal radiotherapy. Endoscopic ultrasound allows accurate localisation and local staging of oesophageal tumours. A method of incorporating this information into the CT planning process is described. Gross tumour volume position changes that occur when using this technique are presented.

Adenocarcinoma↗