PubMed Health⌕ Search

Biomedical subjects

Emmanuel Lansac

Publications and source records attributed to Emmanuel Lansac.

14 recordsLinked to original sources

Aortic prosthetic ring annuloplasty: a useful adjunct to a standardized aortic valve-sparing procedure?

OBJECTIVE: Dilation of aortic annulus, sinuses of Valsalva, and sinotubular junction (STJ) diameters are the characteristic lesions of aortic root aneurysm. The remodeling technique reduces STJ diameter and creates three neosinuses of Valsalva. Alternatively, the reimplantation technique reduces both annulus and STJ diameters to the detriment of aortic root dynamics. Although the remodeling technique is recognized as the most physiological valve-sparing procedure, aortic annulus dilation may jeopardize its results. A standardized approach that combines an external subvalvular aortic prosthetic ring annuloplasty with the remodeling technique is suggested. METHODS: Eighty-three patients underwent an elective aortic root remodeling procedure, either isolated (group 1, n=34) or combined with an external subvalvular aortic prosthetic ring annuloplasty (group 2, n=49). Preoperative aortic regurgitation was 1.59+/-1.1 (group 1) and 1.97+/-1.3 (group 2) (NS). The aortic annulus was more dilated in group 2 than in group 1 (27+/-2.77 mm vs 26.4+/-2.3 mm, p<0.01). Residual aortic regurgitation > or =grade II was the conversion criteria for aortic valve replacement. RESULTS: Operative mortality was 3.6% (n=3). Intraoperative conversion for valve replacement was 32.7% in group 1 (n=11) versus 4.2% in group 2 (n=2) (p<0.001). In group 1, preoperative annulus diameter was larger for converted than for valve-spared patients (27.6+/-1.7 mm vs 25.2+/-1.5 mm, p<0.02). In group 2, implanted aortic ring significantly reduced annulus diameter (20.6+/-1.8 mm) without significant aortic valve gradient (8.3+/-3 mmHg). Follow-up was 17.2+/-13.4 months (group 1) and 10.41+/-7.95 months (group 2). Reoperation for recurrent aortic regurgitation was 13% in group 1 (n=3) versus 4.2% in group 2 (n=2). Echocardiographic follow-up found residual aortic regurgitation < or =grade I in 17 patients in group 1 (90%) versus 43 patients in group 2 (95.5%) and of grade II in two patients in group 1 (10%) and two patients in group 2 (4.5%). CONCLUSION: The addition of external aortic prosthetic ring annuloplasty improves the remodeling technique's operative reproducibility and short-term results. Therefore, its use as a systematical adjunct to the remodeling procedure is suggested. However, further long-term evaluation comparing this valve-sparing procedure to composite graft replacement should define the best surgical strategy for aortic root aneurysm.

Adolescent↗

Kinking of the atrioventricular plane during the cardiac cycle.

Systolic descent of the atrioventricular plane toward the relatively stationary left ventricular apex is well described. As the atrioventricular plane includes two separate valvular units, systolic atrioventricular plane displacement should not be homogenous. In 6 sheep, sonomicrometric crystals were implanted at the base of the right coronary sinus, anterolateral and posteromedial fibrous trigones, posterior mitral annulus, left ventricular apex, and the tips of the anterior and posterior mitral leaflets. The aortomitral angle was calculated and related to simultaneous left ventricular and aortic pressures and mitral valve movement. The aortomitral angle was largest at end diastole (150.73 degrees +/- 15.48 degrees ). During isovolumic contraction, it narrowed rapidly to 144.90 degrees +/- 16.64 degrees , followed by a slower narrowing during ejection until it reached its smallest angle at end systole (139.66 degrees +/- 16.78 degrees ). During isovolumic relaxation, the aortomitral angle increased to 143.66 degrees +/- 16.02 degrees at the beginning of diastole. During the first third of diastole, it narrowed again to 141 degrees +/- 16.24 degrees before re-expanding to maximum at end diastole. During systole, the atrioventricular plane descended non-homogeneously toward the apex, with kinking at the hinge between the aortic and mitral annulus plane. This deformation of the atrioventricular plane has relevance in valve surgery.

Animals↗

Left ventricular endocardial longitudinal and transverse changes during isovolumic contraction and relaxation: a challenge.

Left ventricular (LV) longitudinal and transverse geometric changes during isovolumic contraction and relaxation are still controversial. This confusion is compounded by traditional definitions of these phases of the cardiac cycle. High-resolution sonomicrometry studies might clarify these issues. Crystals were implanted in six sheep at the LV apex, fibrous trigones, lateral and posterior mitral annulus, base of the aortic right coronary sinus, anterior and septal endocardial wall, papillary muscle tips, and edge of the anterior and posterior mitral leaflets. Changes in distances were time related to LV and aortic pressures and to mitral valve opening. At the beginning of isovolumic contraction, while the mitral valve was still open, the LV endocardial transverse diameter started to shorten while the endocardial longitudinal diameter increased. During isovolumic relaxation, while the mitral valve was closed, LV transverse diameter started to increase while the longitudinal diameter continued to decrease. These findings are inconsistent with the classic definitions of the phases of the cardiac cycle.

Animals↗

External aortic annuloplasty ring for valve-sparing procedures.

Two different surgical approaches have been suggested for aortic valve-sparing surgery. My colleagues and I suggest combining the advantages of both approaches by adding an external subvalvular prosthetic ring annuloplasty to the remodeling procedure.

Adult↗

Anterior mitral basal 'stay' chords are essential for left ventricular geometry and function.

BACKGROUND AND AIM OF THE STUDY: Among the anterior mitral basal chords, two particularly strong and thick stay chords (SC) remain under tension during the entire cardiac cycle. Collagen fibers of the anterior mitral leaflet (AML) are oriented from insertion of the SC on the AML to the fibrous trigones (FT), suggesting that local stress is directed from the papillary muscles (PM) over the SC and AML to the FT, maintaining left ventricular (LV) geometry. METHODS: Sonomicrometry crystals were implanted in sheep at the LV apex (A), the anterior (AW) and septal (SW) LV wall, the PM tips (M1 and M2), the SC insertion into the AML (S1 and S2), the posterior (PMA) and lateral (P1 and P2) mitral annulus, the FT (T1 and T2), the tips of the anterior (AL) and posterior (PL) mitral leaflets, and the base of the aortic right coronary sinus (RCS). Changes in distances, areas, and volume were time-related to aortic flow and LV and ascending aorta pressures. Recordings were taken at baseline and after transection of the SC. RESULTS: After transection of the SC, the systolic distance from M1-T1 increased by +0.96 +/- 0.41 mm (p < 0.05) and from M2-T2 by +0.97 +/- 0.42 mm (p < 0.05). The LV length increased at T1-A by +1.14 +/- 0.60 mm (p < 0.05) and at T2-A by +0.97 +/- 0.37 mm (p < 0.05). The aortomitral angle narrowed at end-systole by -3.26 +/- 0.85 degrees (p < 0.05). Transection of the SC reduced dP/dt by -11.20 +/- 5.29% (p < 0.05), maximum aortic flow by -16.89 +/- 7.86% (p < 0.05), and maximum pressure-volume ratio by -10.83 +/- 3.36% (p < 0.05). CONCLUSION: Transection of the anterior mitral SC did not result in mitral regurgitation but induced significant changes in LV geometry, including narrowing of the aortomitral angle and subsequent deterioration of LV function. The SC are essential for maintaining normal LV geometry and function.

Animals↗

Aortic root dynamics are asymmetric.

BACKGROUND AND AIM OF THE STUDY: The presence of conformational changes in the aortic root during the cardiac cycle is well known, but precise information on time-related changes at each level of the root is lacking. METHODS: High-resolution, 3D sonomicrometry (200 Hz) was applied in an acute sheep model. Twelve crystals were implanted in eight sheep at each base (n = 3), commissure (n = 3), sinotubular junction (n = 3) and ascending aorta (n = 3). Under stable hemodynamic conditions, geometric changes of the perimeter of each sinus of Valsalva, sinus height, and twist and root tilt angles were time-related to left ventricluar (LV) and aortic pressures. RESULTS: Expansion of the perimeter of the three sinuses of Valsalva was homogeneous, but in significantly different proportions (p < 0.001): the right sinus expanded (+32.4 +/- 2.4%) more than the left (+29.3 +/- 3.2%), and more than the non-coronary (NC) sinus (+25.8 +/- 1.7%). A similar pattern was found for aortic root height: right greater than left, and left greater than NC sinus (p < 0.001). This asymmetry resulted in changes of the root's twist and tilt angles. Although the twist deformation was consistent for each sheep, no general pattern was found. The aortic root tilt angle (between the basal plane and the commissural plane) was 16.3 +/- 1.5 degrees at end-diastole (angle oriented posteriorly and to the left). During systole, it was reduced by 6.6 +/- 0.5 degrees, aligning the LV outflow tract with the ascending aorta. This tilt angle returned to its original value after valve closure. CONCLUSION: Aortic root expansion is asymmetric, generating precise changes in its tilt angle. During systole, tilt angle reduction resulted in a straight cylinder that probably facilitates ejection; during diastole, the tilt angle increased, probably reducing leaflet stress. These findings should impact upon surgical procedures and the design of new prostheses.

Animals↗

Ischemic mitral valve prolapse: mechanisms and implications for valve repair.

OBJECTIVE: The aim of this study was to assess the mechanisms of prolapse in ischemic mitral valve regurgitation (MR) and the techniques of valve repair. METHODS: Out of 121 patients operated upon for ischemic MR, a prolapse was present in 44 patients (36.4%). The operation was performed emergently in four cases (9.1%) and electively in 40 patients (90.9%). Fifteen patients (34.1%) were operated upon within 60 days following acute myocardial infarction. RESULTS: The diagnosis of prolapse had been overlooked by echography in five cases (11.4%). A commissural area was involved as the site of prolapse in 31 cases (70.4%). The mechanism of prolapse was a papillary muscle (PM) lesion in 38 cases (86.4%) (anterior PM: n=8, posterior PM n=36) or a chordal lesion in six cases (13.6%). PM injury was elongation (n=16), or rupture (total n=1, partial n=21, incomplete n=4). The operative technique was mitral valve repair with Carpentier's techniques in 42 cases (95.5%) or replacement in two cases (4.5%). Hospital mortality was 11.4% (n=4). The mean follow-up was to 44.7+/-29.6 months. Overall survival and freedom from reoperation were 68.3+/-9.0 and 89.9+/-5.7% at 5 years, respectively. Freedom from MR equal or > grade 2 was 69.7+/-9.5% at 5 years. CONCLUSIONS: The mechanisms of ischemic mitral valve prolapse were variable and tightly linked to the PM anatomy. A reliable mitral valve repair could be achieved in most cases with acceptable mid-term results.

Aged↗

Homograft replacement of the mitral valve: eight-year results.

OBJECTIVE: The objective of this study was to assess whether the mitral homograft represents a valuable alternative for complete or partial mitral valve replacement. METHODS: Since 1993, 104 patients underwent mitral homograft replacement surgery. The mean age was 38 +/- 15 years. The causes of mitral valve disease were rheumatic disease (n = 76), infective endocarditis (n = 24), and others (n = 4). Sixty-five of these procedures were total homografts, and 39 were partial homografts. RESULTS: The mean follow-up was 52 +/- 35 months (maximum, 117 months). Overall hospital mortality was 4 (3.8%) of 104 patients and 2.5% versus 8.7% for patients without endocarditis and with endocarditis, respectively (P <.19). There were 9 late deaths (cardiac, 4; noncardiac, 5). There have been 5 early (<3 months) and 10 late reoperations. Of the remaining 77 patients, New York Heart Association class was I in 61, II in 14, and III in 2. Four patients had endocarditis, and 5 had an ischemic or hemorrhagic event. Freedom from major cardiac events was 71% +/- 6% at 8 years (partial at 81% vs total at 63%, P <.19). Among patients with a total homograft, freedom from major cardiac events was 61% +/- 9% and 85% +/- 8% at 6 years in patients younger than and older than 40 years, respectively (P =.09). CONCLUSION: The risk of early dysfunction related to a mismatch between the mitral homograft and the patient's valve is the main pitfall of the technique. Beyond that stage, the results were comparable with those of bioprostheses in a cohort of young patients.

Adult↗

Sonometric study of the normal tricuspid valve annulus in sheep.

BACKGROUND AND AIM OF THE STUDY: Mitral valve dynamic changes during the cardiac cycle have been previously studied in sheep using sonomicrometry. The study aim was to analyze geometric changes of the normal tricuspid annulus in sheep using a similar methodology. This is most likely the first tricuspid valve study using high temporal resolution (200 Hz = 200 data points per second). METHODS: Thirteen crystals were implanted in seven sheep along the annulus (n = 6), at the tips of papillary muscles (n = 3), at the free edge of the leaflets (n = 3), and at the apex of the left ventricle (n = 1). Recordings (10 s) of crystal distances were used to create a three-dimensional (3D) coordinate system based on the least-squares plane of the annulus, and maximum and minimum values were calculated for length, area, and position in xyz coordinates. RESULTS: During the cardiac cycle, the tricuspid annulus area expanded 28.6 +/- 3.6% with similar maximum expansions of each segment along the annulus: septal (10.4 +/- 1.2%), anterior (13.0 +/- 1.5%), and posterior (14.0 +/- 1.6%). The annulus was saddle-shaped, with a circumferential expansion from elliptical at minimum area to more circular at maximum area. The time delay to maximum leaflet area and maximum papillary area occurred 83 +/- 13 ms and 279 +/- 30 ms respectively after maximum annulus area. CONCLUSION: The tricuspid valve undergoes continual and complex geometric changes during the cardiac cycle. In addition, the annulus expands significantly due to similar increases in length of the septal and free wall segments. The annulus is not in a single plane, but is saddle-shaped. The expansion and contraction of the tricuspid valve complex is stepwise, and sequential from base to apex.

Animals↗

Anterior leaflet augmentation with autologous pericardium for mitral repair in rheumatic valve insufficiency.

BACKGROUND AND AIM OF THE STUDY: The mechanism of insufficiency in rheumatic valve disease includes annulus dilatation and restricted leaflet motion. In order to improve the treatment of restriction, the anterior mitral leaflet (AML) can be augmented with a piece of glutaraldehyde-treated autologous pericardium. METHODS: Between January 1995 and December 1999, among 274 patients referred for rheumatic mitral disease, 143 (52%) underwent a valve repair. Of these patients, 81% had pure regurgitation and 19% had significant associated stenosis. Ring annuloplasty was used in all cases. Techniques used to treat the restrictive component of the regurgitation were compared in two consecutive cohorts of patients, either with (n = 62) or without (n = 81) AML augmentation. Mean patient age was 42 +/- 3 years, and all preoperative variables were comparable except for the incidence of redo patients, who all underwent AML extension. RESULTS: In-hospital mortality was 0.7% (n = 1 with AML extension), and there was one early reoperation for pericardial patch dehiscence. After a mean follow up of 3.2 years, there was one sudden death (no AML extension). The reoperation rate was lower with (2.5%) than without (12.9%) AML augmentation (p <0.05). Echocardiography showed a lower incidence in recurrence of mitral insufficiency when AML augmentation was performed (grade 2, 9% versus grade 3, 3%) as compared to no AML augmentation (grade 2, 35% versus grade 3, 14%) (p <0.05). The mitral orifice area was larger (AML augmentation 2.2 +/- 0.3 cm versus no AML augmentation 1.8 +/- 0.4 cm2). CONCLUSION: Ring annuloplasty alone failed to correct rheumatic mitral insufficiency in all cases. AML augmentation improved the quality of the repair, and decreased the risk of reoperation.

Adolescent↗

Anterior mitral leaflet mobility is limited by the basal stay chords.

BACKGROUND: We hypothesize that 2 tendon-like anterior basal stay chords, which remain taut during the entire cardiac cycle, limit the motion of the anterior mitral leaflet. METHODS AND RESULTS: Sonomicrometric crystals were implanted in 6 sheep at the insertion of stay chords at anterior mitral leaflet (S1 and S2), papillary muscle tips, fibrous trigones, mitral annulus, and the tip of the anterior leaflet (AL). Distances between crystals were recorded before and after section of stay chords. During the cardiac cycle, the angle alpha between mitral annulus and AL changed by +54.2+/-12.4 degrees; the angles between mitral annulus and S1 (beta1) changed by +25.7+/-14.6 degrees, and between mitral annulus and S2 (beta2) by +20.4+/-7.8 degrees. During diastole, AL twice crossed the virtual plane formed by the stay chords: during E-wave by a maximum of 6.5 mm (mean, 2.5+/-2.2 mm) and during A-wave by a maximum of 3.2 mm (mean, 1.7+/-0.9 mm). After section of both stay chords, total anterior mitral leaflet motion increased as follows: AL, +6.9+/-3.4 degrees; S1, +13.1+/-4.4 degrees; and S2, +30.9+/-11.7 degrees (P<0.05). CONCLUSIONS: Although the lateral movement of anterior mitral leaflet is limited by stay chords, the midportion moves unimpaired toward the septum, like a sail, between the 2 stay chords during diastole. A diastolic left ventricular-inflow and systolic left ventricular-outflow funnel mechanism is created. Stay chord section increased lateral anterior mitral leaflet movement.

Animals↗

Dynamic balance of the aortomitral junction.

OBJECTIVE: The aortic and mitral valves have been studied in isolation, as if their functions were independent. We hypothesized that both valves work in synchrony on the basis of the shared myocardial pump and orifice. METHODS: Six sonometric crystals (7 sheep) were placed in both trigones, the midpoint of the anterior and posterior anulus, and the lateral extremities of the posterior anulus. In a separate series of animals, 3 crystals (8 sheep) were implanted in the aortic annular base of the right, left, and noncoronary sinuses of Valsalva. In an acute, open-chest model, under stable hemodynamic conditions, geometric changes were time related to simultaneous left ventricular and aortic pressures. RESULTS: From mid-diastole to end-systole, the mitral anulus area contracted by -16.1% +/- 1.9% (mean +/- SEM), whereas the aortic base area expanded by +29.8% +/- 3.3% during systole. The mitral anulus deformation was heterogeneous. In systole, the anterior mitral anulus expanded (intertrigonal distance, +11.5% +/- 2.3%) and the posterior mitral anulus contracted (distance between lateral extremities of the posterior anulus, -12.1% +/- 1.5%). The intertrigonal distance corresponded to the base of the left and noncoronary sinus of Valsalva, which expanded similarly during systole (+12.9% +/- 2.0%). The anteroposterior diameter of the mitral anulus was reduced twice that of the transverse diameter. This disparity of reduction can be explained by the posterior displacement of the intertrigonal area corresponding to the systolic aortic root expansion. CONCLUSIONS: Mitral anulus deformation is closely related to aortic root dynamics. During systole, the posterior movement of the aortic curtain allows for aortic root expansion, probably to maximize ejection, whereas during diastole, aortic root reduction participates in mitral anulus dilatation. These findings should affect mitral and aortic surgical approaches.

Animals↗

A temporarily stented, autologous pericardial aortic valve prosthesis.

BACKGROUND AND AIM OF THE STUDY: A new bioprosthesis has been developed that is: (i) constructed from glutaraldehyde-treated autologous pericardium due to its lack of antigenicity and low cost; (ii) easily constructed in the operating room; (iii) stentless but easy to implant by using a temporary stent that is removed once its function is no longer necessary; and (iv) implanted with a single proximal suture and three commissural stitches. METHODS: This prosthesis was implanted in the subcoronary aortic position of six sheep. The mean prosthesis size was 19.7 +/- 3.5 mm, and manufacturing time 16 +/- 3 min. Cardiopulmonary bypass and cross-clamp times were 142.5 +/- 26.7 min and 100.2 +/- 28.8 min, respectively. Three sheep were euthanized at three, seven, or 27 days, and the remainder at five months postoperatively. RESULTS: In all cases the valve was competent and the single commissural stitches were well-anchored. The pericardium was pliable in all cases, but one animal had obvious endocarditis (at 27 days). Small calcific nodules were found at the commissures in valves explanted at five months. Histology showed an intact collagen and elastin structure, and neointimal growth was seen covering the basal quarter of the leaflets and commissures. CONCLUSION: This new bioprosthesis might offer a particularly attractive alternative for the young patient population of the developing world. The simplicity of construction, low cost, and absence of any need for anticoagulation makes this prosthesis close to the ideal aortic valve substitute.

Animals↗