PubMed Health⌕ Search

Biomedical subjects

Emuri Abe

Publications and source records attributed to Emuri Abe.

4 recordsLinked to original sources

Diagnosis of adrenal insufficiency in severe sepsis and septic shock.

RATIONALE: Diagnosis of adrenal insufficiency in critically ill patients has relied on random or cosyntropin-stimulated cortisol levels, and has not been corroborated by a more accurate diagnostic standard. OBJECTIVE: We used the overnight metyrapone stimulation test to investigate the diagnostic value of the standard cosyntropin stimulation test, and the prevalence of sepsis-associated adrenal insufficiency. METHODS: This was an inception cohort study. MEASUREMENTS AND RESULTS: In two consecutive septic cohorts (n = 61 and n = 40), in 44 patients without sepsis and in 32 healthy volunteers, we measured (1) serum cortisol before and after cosyntropin stimulation, albumin, and corticosteroid-binding globulin levels, and (2) serum corticotropin, cortisol, and 11beta-deoxycortisol levels before and after an overnight metyrapone stimulation. Adrenal insufficiency was defined by postmetyrapone serum 11beta-deoxycortisol levels below 7 microg/dl. More patients with sepsis (31/61 [59% of original cohort with sepsis] and 24/40 [60% of validation cohort with sepsis]) met criteria for adrenal insufficiency than patients without sepsis (3/44; 7%) (p < 0.001 for both comparisons). Baseline cortisol (< 10 microg/dl), Delta cortisol (< 9 microg/dl), and free cortisol (< 2 microg/dl) had a positive likelihood ratio equal to infinity, 8.46 (95% confidence interval, 1.19-60.25), and 9.50 (95% confidence interval, 1.05-9.54), respectively. The best predictor of adrenal insufficiency (as defined by metyrapone testing) was baseline cortisol of 10 microg/dl or less or Delta cortisol of less than 9 microg/dl. The best predictors of normal adrenal response were cosyntropin-stimulated cortisol of 44 microg/dl or greater and Delta cortisol of 16.8 microg/dl or greater. CONCLUSIONS: In sepsis, adrenal insufficiency is likely when baseline cortisol levels are less than 10 microg/dl or delta cortisol is less than 9 microg/dl, and unlikely when cosyntropin-stimulated cortisol level is 44 microg/dl or greater or Delta cortisol is 16.8 microg/dl or greater.

Adrenal Insufficiency↗

A novel LC-ESI-MS-MS method for sensitive quantification of colchicine in human plasma: application to two case reports.

A novel method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the identification and quantification of colchicine in plasma or whole blood. Colchicine was isolated from plasma using a liquid-liquid extraction with dichloromethane at pH 8.0 and embutramide as an internal standard, with satisfactory extraction recoveries. Solutes were separated on a 3-microm C18 Uptisphere (Interchim) column (150 x 2.0-mm i.d.) using acetonitrile/2 mM NH4COOH pH 3.8 buffer (50:50, v/v) as the mobile phase with a flow-rate of 200 microL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the ion m/z 400.1 for colchicine and m/z 294.1 for embutramide. The most intense daughter ion of colchicine (m/z 358.1) and embutramide (m/z 207.9) were used for quantification. Retention times were 2.40 and 4.25 min for colchicine and embutramide, respectively. Calibration curves were linear in the 0.50-50 ng/mL range. The limits of detection and quantification were 0.05 ng/mL and 0.50 ng/mL, respectively. The intra- and interassay precisions were < 14%, and the intra- and interassay accuracies were in the 97-105.8% range at either 2 or 20 ng/mL. A fatal case of colchicine self-poisoning with a lethal blood concentration of 60 ng/mL and nonfatal case with a plasma sample collected very late (at least 36 h after the ingestion) are presented. The described method enables the unambiguous identification and quantification of colchicine with a very good sensitivity, using only 1 mL of sample.

Adult↗

Sensitive quantification of apomorphine in human plasma using a LC-ESI-MS-MS method.

An analytical method based on liquid chromatography coupled with ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the identification and quantification of apomorphine in human plasma. Apomorphine was isolated from 0.5 mL of plasma using a liquid-liquid extraction with diethyl ether and boldine as internal standard, with satisfactory extraction recoveries. Analytes were separated on a 5-microm C18 Highpurity (Thermohypersil) column (150 mm x 2.1 mm I.D.) maintained at 30 degrees C, coupled to a precolumn (C18, 5-microm, 10 mm x 2.0 mm I.D., Thermo). The elution was achieved isocratically with a mobile phase of 2 mM NH4COOH buffer pH 3.8/acetonitrile (50/50, vol/vol) at a flow rate of 200 microL per minute. Data were collected either in full-scan MS mode at m/z 150 to 500 or in full-scan tandem mass spectrometry mode, selecting the [M+H]ion at m/z 268.0 for apomorphine and m/z 328.0 for boldine. The most intense daughter ion of apomorphine (m/z 237.1) and boldine (m/z 297.0) were used for quantification. Retention times were 2.03 and 2.11 minutes for boldine and apomorphine, respectively. Calibration curves were linear in the 0.025 to 20 ng/mL range. The limits of detection and quantification were 0.010 ng/mL and 0.025 ng/mL, respectively. Accuracy and precision of the assay were measured by analyzing 54 quality control samples for 3 days. At concentrations of 0.075, 1.5, and 15 ng/mL, intraday precisions were less than 10.1%, 5.3%, and 3.8%, and interday precisions were less than 4.8%, 6.6%, and 6.5%, respectively. Accuracies were in the 99.5 to 104.2% range. An example of a patient who was given 6 mg of apomorphine subcutaneously is shown, with concentrations of 14.1 ng/mL after 30 minutes and 0.20 ng/mL after 6 hours. The method described enables the unambiguous identification and quantification of apomorphine with very good sensitivity using only 0.5 mL of sample, and is very convenient for therapeutic drug monitoring and pharmacokinetic studies.

Apomorphine↗

A rapid and sensitive high-performance liquid chromatography method for determination of embutramide (a Tanax or T61 component) in human blood with photodiode-array UV detection.

Tanax or T61 is an euthanasia solution commonly used in veterinary medicine. Embutramide is one of the three components. In accidental intoxication, suicide, or suicide attempt, the determination of embutramide is needed to confirm the hypothesis of intoxication. Because the amount of sample is sometimes limited in forensic cases, a new rapid and sensitive high-performance liquid chromatography method using only 0.1 mL of blood has been developed with liquid-liquid extraction. The eluate was monitored with a photodiode-array detector with a fixed wavelength at 273 nm. The method provided extraction recoveries greater than 83%. The detection limit was 0.2 mg/L, and the limit of quantitation was 0.6 mg/L. The linearity of standards was excellent (r > 0.997). Intra- and interday precisions were acceptable with a coefficient of variation <or= 10.7% in all cases. This method was applied to the first case of suicide by a known quantity of embutramide after intravenous administration, showing a blood concentration of 90 mg/L and allowing estimation of the embutramide volume of distribution in humans (1.6 L/kg)

Adult↗