Ergin Atalar

Publications and source records attributed to Ergin Atalar.

At least 19 recordsLinked to original sources

Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field.

The homogeneity and stability of the static magnetic field are of paramount importance to the accuracy of MR procedures that are sensitive to phase errors and magnetic field inhomogeneity. It is shown that intense gradient utilization in clinical horizontal-bore superconducting MR scanners of three different vendors results in main magnetic fields that vary on a long time scale both spatially and temporally by amounts of order 0.8-2.5 ppm. The observed spatial changes have linear and quadratic variations that are strongest along the z direction. It is shown that the effect of such variations is of sufficient magnitude to completely obfuscate thermal phase shifts measured by proton-resonance frequency-shift MR thermometry and certainly affect accuracy. In addition, field variations cause signal loss and line-broadening in MR spectroscopy, as exemplified by a fourfold line-broadening of metabolites over the course of a 45 min human brain study. The field variations are consistent with resistive heating of the magnet structures. It is concluded that correction strategies are required to compensate for these spatial and temporal field drifts for phase-sensitive MR protocols. It is demonstrated that serial field mapping and phased difference imaging correction protocols can substantially compensate for the drift effects observed in the MR thermometry and spectroscopy experiments.

Brain↗

MRI-guided gene therapy.

MRI has the ability to generate high-contrast and high-resolution images, to obtain multiple diagnostic evaluations of organ function and morphology, and to provide multiple image planes with no risk of ionizing radiation. Recent efforts have focused on using MR technology to monitor gene delivery, to enhance gene transfection/transduction, and to track gene expression. This review summarizes the current status of MRI-guided gene therapy.

Animals↗

A preliminary analysis and model of prostate injection distributions.

PURPOSE: Understanding the internal dynamics of prostate injections, particularly injection pattern distribution is a key step to developing new therapies for prostate disease that may be best served with a direct injection approach. Due to excellent properties involving liquid contrast agents, MRI can be used for targeting and monitoring of injections into organs and tissues. MATERIALS AND METHODS: Eleven intraprostatic injections were performed in vivo with canines using a custom transrectal guiding and imaging system for use in a standard 1.5 T MR scanner. In addition, 25 injections were performed on excised cadaveric human prostates, using a MedRad Spectris injector system. MRI was used to guide the injections and monitor intraparenchymal injection distribution. RESULTS: T1 and T2-weighted MR images were correlated with histology to produce three-dimensional data sets that can be used to analyze trends in injection patterns. This analysis was used to develop strategies for injection prediction such as gadolinium pre-injections and diffusion-weighted imaging guidance. In addition, a rough model of prostate injections is described, and a preliminary injection guide is developed that takes into account the individual clinician's goals for therapy. CONCLUSIONS: MR visualization of injected therapeutic agents allows for prediction and monitoring of drug distributions, possibly improving efficacy and reducing side effects. Injection analysis and modeling may be used to assist in optimizing clinical treatments that require or would benefit from focal parenchymal injections into the prostate.

Animals↗

Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

BACKGROUND: Endovascular recanalization (guidewire traversal) of peripheral artery chronic total occlusion (CTO) can be challenging. X-ray angiography resolves CTO poorly. Virtually "blind" device advancement during x-ray-guided interventions can lead to procedure failure, perforation, and hemorrhage. Alternatively, MRI may delineate the artery within the occluded segment to enhance procedural safety and success. We hypothesized that real-time MRI (rtMRI)-guided CTO recanalization can be accomplished in an animal model. METHODS AND RESULTS: Carotid artery CTO was created by balloon injury in 19 lipid-overfed swine. After 6 to 8 weeks, 2 underwent direct necropsy analysis for histology, 3 underwent primary x-ray-guided CTO recanalization attempts, and the remaining 14 underwent rtMRI-guided recanalization attempts in a 1.5-T interventional MRI system. Real-time MRI intervention used custom CTO catheters and guidewires that incorporated MRI receiver antennae to enhance device visibility. The mean length of the occluded segments was 13.3+/-1.6 cm. The rtMRI-guided CTO recanalization was successful in 11 of 14 swine and in only 1 of 3 swine with the use of x-ray alone. After unsuccessful rtMRI (n=3), x-ray-guided attempts were also unsuccessful. CONCLUSIONS: Recanalization of long CTO is entirely feasible with the use of rtMRI guidance. Low-profile clinical-grade devices will be required to translate this experience to humans.

Angioplasty↗

Real-time MRI guided atrial septal puncture and balloon septostomy in swine.

Cardiac perforation during atrial septal puncture (ASP) might be avoided by improved image guidance. X-ray fluoroscopy (XRF), which guides ASP, visualizes tissue poorly and does not convey depth information. Ultrasound is limited by device shadows and constrained imaging windows. Alternatively, real-time MRI (rtMRI) provides excellent tissue contrast in any orientation and may enable ASP and balloon atrial septostomy (BAS) in swine. Custom MRI catheters incorporated "active" (receiver antenna) and "passive" (iron or gadolinium) elements. Wholly rtMRI-guided transfemoral ASP and BAS were performed in 10 swine in a 1.5T interventional suite. Hemodynamic results were measured with catheters and velocity encoded MRI. Successful ASP was performed in all 10 animals. Necropsy confirmed septostomy confined within the fossa ovalis in all. BAS was successful in 9/10 animals. Antenna failure in a re-used needle led to inadvertent vena cava tear prior to BAS in 1 animal. ASP in the same animal was easily performed using a new needle. rtMRI illustrated clear device-tissue-lumen relationships in multiple orientations, and facilitated simple ASP and BAS. The mean procedure time was 19 +/- 10 minutes. Septostomy achieved a mean left to right shunt ratio of 1.3:1 in these healthy animals. Interactive rtMRI permits rapid transcatheter ASP and BAS in swine. Further technical development may enable novel applications.

Angioplasty, Balloon, Coronary↗

Transrectal prostate biopsy and fiducial marker placement in a standard 1.5T magnetic resonance imaging scanner.

PURPOSE: We investigated the accuracy and feasibility of a system that provides transrectal needle access to the prostate concurrent with 1.5 Tesla MRI which previously has not been possible. MATERIALS AND METHODS: In 5 patients with previously diagnosed prostate cancer, MRI guided intraprostatic placement of gold fiducial markers (4 procedures) and/or prostate biopsy (3 procedures) was performed using local anesthesia. RESULTS: Mean procedure duration was 76 minutes and all patients tolerated the intervention well. Procedure related adverse events included self-limited hematuria and hematochezia following 3 of 8 procedures (all resolved in less than 1 week). Mean needle placement accuracy was 1.9 mm for the fiducial marker placement studies and 1.8 mm for the biopsy procedures. Mean fiducial marker placement accuracy was 4.8 mm and the mean fiducial marker placement accuracy transverse to the needle direction was 2.6 mm. All patients who underwent the procedure were able to complete their course of radiotherapy without delay or complication. CONCLUSIONS: While studies of clinical usefulness are warranted, transrectal 1.5 T MRI guided prostate biopsy and fiducial marker placement is feasible using this system, providing new opportunities for image guided diagnostic and therapeutic prostate interventions.

Biopsy, Needle↗

Evaluation of MR/fluoroscopy-guided portosystemic shunt creation in a swine model.

PURPOSE: To evaluate three different percutaneous portosystemic shunts created with magnetic resonance (MR) imaging and fluoroscopy guidance in a swine model. MATERIALS AND METHODS: In stage 1 of the experiment, an active MR intravascular needle system was created for needle tracking and extracaval punctures. Twenty inferior vena cava (IVC)/superior mesenteric vein (SMV)/portal vein (PV) punctures were performed in 10 swine (weight, 40-45 kg) in a 1.5-T short-bore interventional MR imager. With use of a real-time MR imaging sequence, the needle was guided through the IVC and into the SMV or PV (N = 20 punctures). After confirmation, a wire was advanced into the portal venous system under MR imaging guidance (N = 20). In stage 2, animals were transferred to the radiographic fluoroscopy suite for deployment of shunts. Three different shunts were evaluated in this study: (i) a commercial stent-graft, (ii) a prototype bridging stent, and (iii) a prototype nitinol vascular anastomotic device. Postprocedural necropsy was performed in all animals. RESULTS: Successful MR-guided IVC/SMV punctures were performed in all 20 procedures (100%). All three shunts were deployed. Stent-grafts had the poorest mechanism for securing a shunt. The vascular anastomotic device and the bridging stent had more secure anchoring mechanisms but also had higher technical failure rates (50% and 40%, respectively). When deployed successfully, the vascular anastomotic device resulted in no bleeding at the sites of punctures at necropsy. CONCLUSION: Percutaneous shunts and vascular anastomoses between the portal mesenteric venous system and IVC were successfully created with use of a combination of MR imaging and conventional fluoroscopy for guidance.

Alloys↗

Percutaneous MR imaging-guided transvascular access of mesenteric venous system: study in swine model.

PURPOSE: To determine if, with use of magnetic resonance (MR) imaging guidance alone, transcaval puncture of the superior mesenteric vein (SMV) and/or portal vein is feasible with a percutaneous femoral vein approach. MATERIALS AND METHODS: The Institutional Animal Care and Use Committee approved the animal studies. Ten inferior vena cava (IVC)-SMV punctures were performed in six pigs. An active MR intravascular needle system was used for all transvascular punctures, and all procedures were performed with a 1.5-T MR unit. The needle was introduced via a 12-F femoral vein sheath and advanced into the IVC by using a real-time gradient-recalled-echo sequence (3.4/1.2 [repetition time msec/echo time msec], 45 degrees flip angle, and six to eight frames per second). Fast transverse spoiled gradient-recalled acquisition in the steady state (SPGR) (6.0/1.5, 60 degrees flip angle, one frame per second) was performed to confirm needle trajectory. The needle system was advanced under real-time MR imaging to puncture the SMV. The location of the needle tip was confirmed with a fast spin-echo sequence (1904/4.5, 36-cm field of view). A direct MR portogram was obtained after the administration of gadopentetate dimeglumine at a concentration of 25% with fast SPGR (6/1.3, 90 degrees flip angle, no section selection, three frames per second). Success was defined as entry into the mesenteric venous system without traversal of any retroperitoneal organs or adjacent vasculature. RESULTS: Successful MR imaging-guided IVC-SMV punctures were performed in all 10 procedures (100%). The needle was fully visualized as it traversed the retroperitoneum and entered the SMV. MR portograms were successfully obtained following all punctures through the needle. Conventional transverse MR imaging helped confirm that the needle did not traverse any retroperitoneal organs or vessels. CONCLUSION: With use of only MR imaging guidance and an active MR imaging intravascular needle system, the authors were able to successfully puncture the SMV from the IVC with direct visualization of the needle and all retroperitoneal structures.

Animals↗

Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine.

OBJECTIVES: This study tested the hypotheses that endografts can be visualized and navigated in vivo solely under real-time magnetic resonance imaging (rtMRI) guidance to repair experimental abdominal aortic aneurysms (AAA) in swine, and that MRI can provide immediate assessment of endograft apposition and aneurysm exclusion. BACKGROUND: Endovascular repair for AAA is limited by endoleak caused by inflow or outflow malapposition. The ability of rtMRI to image soft tissue and flow may improve on X-ray guidance of this procedure. METHODS: Infrarenal AAA was created in swine by balloon overstretch. We used one passive commercial endograft, imaged based on metal-induced MRI artifacts, and several types of homemade active endografts, incorporating MRI receiver coils (antennae). Custom interactive rtMRI features included color coding the catheter-antenna signals individually, simultaneous multislice imaging, and real-time three-dimensional rendering. RESULTS: Eleven repairs were performed solely using rtMRI, simultaneously depicting the device and soft-tissue pathology during endograft deployment. Active devices proved most useful. Intraprocedural MRI provided anatomic confirmation of stent strut apposition and functional corroboration of aneurysm exclusion and restoration of laminar flow in successful cases. In two cases, there was clear evidence of contrast accumulation in the aneurysm sac, denoting endoleak. CONCLUSIONS: Endovascular AAA repair is feasible under rtMRI guidance. Active endografts facilitate device visualization and complement the soft tissue contrast afforded by MRI for precise positioning and deployment. Magnetic resonance imaging also permits immediate post-procedural anatomic and functional evaluation of successful aneurysm exclusion.

Angioplasty↗

Magnetic resonance image-guided trans-septal puncture in a swine heart.

PURPOSE: To test the feasibility of performing magnetic resonance (MR)-guided trans-septal punctures in the swine heart. MATERIALS AND METHODS: All procedures were performed in a 1.5-T MR scanner. A novel, active MR intravascular needle system was utilized for needle tracking and septal punctures. Trans-septal punctures were performed in five swine using electrocardiogram (ECG)-gated high resolution and non-ECG-gated, real-time MR imaging techniques. The intravascular needle was advanced over a guidewire from the femoral vein. Once the needle was in proper position, trans-septal punctures were made. RESULTS: Active tracking of the needle traversing the septum was possible. The location of the catheter tip was confirmed using real time gradient recalled echo (GRE). After a confirmatory ventriculogram with gadolinium-DTPA, a 0.014-inch guidewire was advanced into the left atrium and left ventricle. All punctures were made with no change in cardiac rhythm or rate; postmortem analysis was performed on all animals and demonstrated that 18/19 (95%) punctures were directly through the fossa ovalis. CONCLUSION: Using only MR guidance and a novel active intravascular needle system, we were able to repeatedly puncture the fossa ovalis in a swine heart from a transfemoral approach, with direct visualization of all components, including the needle, the atria, the fossa ovalis, and the surrounding vasculature.

Animals↗

Development of a 0.014-inch magnetic resonance imaging guidewire.

The purpose of this study was to develop a standard 0.014-inch intravascular magnetic resonance imaging guidewire (MRIG), a coaxial cable with an extension of the inner conductor, specifically designed for use in the small vessels. After a theoretical analysis, the 0.014-inch MRIG was built by plating/cladding highly electrically conductive materials, silver or gold, over the inside and outside of the coaxial conductors. The conductors were made of superelastic, nonmagnetic, biocompatible materials, Nitinol or MP35N. Then, in comparison with a previously designed 0.032-inch MRIG, the performance of the new 0.014-inch MRIG in vitro and in vivo was successfully evaluated. This study represents the initial work to confirm the critical role of highly conductive and superelastic materials in building such small-size MRIGs, which are expected to generate high-resolution MR imaging of vessel walls/plaques and guide endovascular interventional procedures in the small vessels, such as the coronary arteries.

Alloys↗

Simultaneous radiofrequency (RF) heating and magnetic resonance (MR) thermal mapping using an intravascular MR imaging/RF heating system.

Previous studies have confirmed the possibility of using an intravascular MR imaging guidewire (MRIG) as a heating source to enhance vascular gene transfection/expression. This motivated us to develop a new intravascular system that can perform MR imaging, radiofrequncy (RF) heating, and MR temperature monitoring simultaneously in an MR scanner. To validate this concept, a series of mathematical simulations of RF power loss along a 0.032-inch MRIG and RF energy spatial distribution were performed to determine the optimum RF heating frequency. Then, an RF generator/amplifier and a filter box were built. The possibility for simultaneous RF heating and MR thermal mapping of the system was confirmed in vitro using a phantom, and the obtained thermal mapping profile was compared with the simulated RF power distribution. Subsequently, the feasibility of simultaneous RF heating and temperature monitoring was successfully validated in vivo in the aorta of living rabbits. This MR imaging/RF heating system offers a potential tool for intravascular MR-mediated, RF-enhanced vascular gene therapy.

Animals↗

MR-guided interventions for prostate cancer.

MR imaging is currently the most effective diagnostic imaging tool for visualizing the anatomy and pathology of the prostate gland. Currently, the practicality and cost effectiveness of transrectal ultrasound dominates image guidance for needle-based prostate interventions. Challenges to the integration of diagnostic and interventional MR imaging have included the lack of real-time feed-back, the complexity of the imaging technique, and limited access to the perineum within the geometric constraints of the MR imaging scanner. Two basic strategies have been explored and clinically demonstrated in the literature: (1) coregistration of previously acquired diagnostic MR imaging to interventional TRUS or open scanner MR images, and (2) stereotactic needle interventions within conventional diagnostic scanners using careful patient positioning or the aid of simple manipulators. Currently, researchers are developing techniques that render MR imaging the method of choice for the direct guidance of many procedures. This article focuses on needle-based interventions for prostate cancer, including biopsy, brachytherapy, and thermal therapy With rapid progress in biologic imaging of the prostate gland, the authors believe that MR imaging guidance will play an increasing role in the diagnosis and treatment of prostate cancer.

Biopsy, Needle↗

Design of a novel MRI compatible manipulator for image guided prostate interventions.

This paper reports a novel remotely actuated manipulator for access to prostate tissue under magnetic resonance imaging guidance (APT-MRI) device, designed for use in a standard high-field MRI scanner. The device provides three-dimensional MRI guided needle placement with millimeter accuracy under physician control. Procedures enabled by this device include MRI guided needle biopsy, fiducial marker placements, and therapy delivery. Its compact size allows for use in both standard cylindrical and open configuration MRI scanners. Preliminary in vivo canine experiments and first clinical trials are reported.

Animals↗

Magnetic resonance imaging-guided coronary interventions.

Magnetic resonance imaging (MRI) guidance for coronary interventions offers potential advantages over conventional x-ray angiography. Advantages include the use of nonionizing radiation, combined assessment of anatomy and function, and three-dimensional assessment of the coronary arteries leading to the myocardium. These advantages have prompted a series of recent studies in this field. Real-time coronary MR angiography, with low-dose catheter-directed intraarterial (IA) infusion of contrast media, has achieved in-plane spatial resolution as low as 0.8 x 0.8 mm2 and temporal resolution as short as 130 msec per image. Catheter-based IA injection of contrast agent has proven useful in the collection of multislice and three-dimensional images, not only for coronary intervention guidance, but also in the assessment of regional myocardial perfusion fed by the affected vessel. Actively visible guidewires and guiding catheters, based on the loopless antenna concept, have been effectively used to negotiate tortuous coronary vessels during catheterization, permitting placement of coronary angioplasty balloon catheters. Passive tracking approaches have been used to image contrast agent-filled coronary catheters and to place susceptibility-based endovascular stents. Although the field is in its infancy, these early results demonstrate the feasibility for performing MRI-guided coronary interventions. Although further methodological and technical developments are required before these methods become clinically applicable, we anticipate that MRI someday will be included in the armamentarium of techniques used to diagnose and treat coronary artery disease.

Contrast Media↗

System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner.

A technique for transperineal high-dose-rate (HDR) prostate brachytherapy and needle biopsy in a standard 1.5 T MRI scanner is demonstrated. In each of eight procedures (in four patients with intermediate to high risk localized prostate cancer), four MRI-guided transperineal prostate biopsies were obtained followed by placement of 14-15 hollow transperineal catheters for HDR brachytherapy. Mean needle-placement accuracy was 2.1 mm, 95% of needle-placement errors were less than 4.0 mm, and the maximum needle-placement error was 4.4 mm. In addition to guiding the placement of biopsy needles and brachytherapy catheters, MR images were also used for brachytherapy treatment planning and optimization. Because 1.5 T MR images are directly acquired during the interventional procedure, dependence on deformable registration is reduced and online image quality is maximized.

Biopsy, Needle↗