Ergin Tönük

Publications and source records attributed to Ergin Tönük.

5 recordsLinked to original sources

Dynamic function of the fibula. Gait analysis evaluation of three different parts of the shank after fibulectomy: proximal, middle and distal.

The purpose of this case study was to investigate the dynamic features of fibular movement to gait pattern by analyzing the gait of individuals with three different parts of the fibula resected. Gait analyses revealed that proximal fibula resection impaired knee stability, whereas distal fibula resection disturbed ankle kinematics significantly. Except a mild secondary quadriceps weakness, middle fibula resection did not cause a significant biomechanical disturbance on gait.

Adult↗

Nonlinear viscoelastic material property estimation of lower extremity residual limb tissues.

Axisymmetric nonlinear finite-element analysis was used to simulate force-relaxation and creep data obtained during in vivo indentation of the residual limb soft tissues of six individuals with trans-tibial amputation [1]. The finite-element models facilitated estimation of an appropriate set of nonlinear viscoelastic material coefficients of extended James-Green-Simpson material formulation for bulk soft tissue at discrete, clinically relevant test locations. The results indicate that over 90% of the experimental data can be simulated using the two-term viscoelastic Prony series extension of James-Green-Simpson material formulation. This phenomenological material formulation could not, however, predict the creep response from relaxation experiments, nor the relaxation response from creep experiments [2-5]. The estimated material coefficients varied with test location and subject indicating that these coefficients cannot be readily extrapolated to other sites or individuals.

Amputation, Surgical↗

An anatomical study of the meniscofibular ligament.

We examined the anatomical structure of a ligament (ligamentum meniscofibulare) between apex fibulae and lateral meniscus by macroscopic and microscopic dissection and transillumination method in 50 knees of 25 cadavers (5 were fresh). We analyzed the function of this ligament, which runs between the head of the fibulae and lateral meniscus. The existence of a connection between knee joint and proximal tibiofibular joint was demonstrated by injecting colored liquid into the knee joint space and transillumination. The mensicofibular ligament is a capsular ligament originating from the lateral meniscus that is anterior to the popliteal muscle tendon. The meniscofibular ligament, which is attached to fibula with rotatory motion at one end and to the lateral meniscus at the other, is believed to position the lateral meniscus and therefore to play a key role in the knee joint.

Cadaver↗

Nonlinear elastic material property estimation of lower extremity residual limb tissues.

The interface stresses between the residual limb and prosthetic socket have been studied to investigate prosthetic fit. Finite-element models of the residual limb-prosthetic socket interface facilitate investigation of the mechanical interface and may serve as a potential tool for future prosthetic socket design. However, the success of such residual limb models to date has been limited, in large part due to inadequate material formulations used to approximate the mechanical behavior of residual limb soft tissues. Nonlinear finite-element analysis was used to simulate force-displacement data obtained during in vivo rate-controlled (1, 5, and 10 mm/s) cyclic indentation of the residual limb soft tissues of seven individuals with transtibial amputation. The finite-element models facilitated determination of an appropriate set of nonlinear elastic material coefficients for bulk soft tissue at discrete clinically relevant test locations. Axisymmetric finite-element models of the residual limb bulk soft tissue in the vicinity of the test location, the socket wall and the indentor tip were developed incorporating contact analysis, large displacement, and large strain, and the James-Green-Simpson nonlinear elastic material formulation. Model dimensions were based on medical imaging studies of the residual limbs. The material coefficients were selected such that the normalized sum of square error (NSSE) between the experimental and finite-element model indentor tip reaction force was minimized. A total of 95% of the experimental data were simulated using the James-Green-Simpson material formulation with an NSSE less than 5%. The respective James-Green-Simpson material coefficients varied with subject, test location, and indentation rate. Therefore, these coefficients cannot be readily extrapolated to other sites or individuals, or to the same site and individual some time after testing.

Amputation Stumps↗

Accuracy of a manual torque application device for morse-taper implants: a technical note.

PURPOSE: The objective of this study was to compare torques applied by new and used manual torque devices for Morse-taper implants. MATERIAL AND METHODS: Fifteen ITI manual torque devices were tested. Those in group 1 (n = 5) were new (ie, never used), those in group 2 (n = 5) had been used 50 to 200 times, and those in group 3 (n = 5) had been used 500 to 1,000 times. The torques applied by each device were measured for 35 Ncm and 15 Ncm targets in an experimental setup by a custom-made wrench with strain gauges connected to a data acquisition system. The strain-gauge signals were simultaneously delivered to a computer at a sample rate of 10,000 Hz and converted to torque units. RESULTS: New devices applied higher torques than used devices for the 35-Ncm torque target (P < .05). The torques applied by group 3 devices were approximately 1.5 Ncm lower than those of other groups for the 35-Ncm target and approximately 1 Ncm lower for the 15-Ncm target. DISCUSSION AND CONCLUSION: ITI manual torque devices deliver consistent torque output, although a slight decrease occurs as a consequence of clinical use.

Dental Implantation, Endosseous↗