PubMed Health⌕ Search

Biomedical subjects

Ergun Erçelebi

Publications and source records attributed to Ergun Erçelebi.

3 recordsLinked to original sources

Comparison of subspace-based methods with AR parametric methods in epileptic seizure detection.

Electroencephalography is an important clinical tool for the evaluation and treatment of neurophysiologic disorders related to epilepsy. Careful analyses of the electroencephalograph (EEG) records can provide valuable insight and improved understanding of the mechanisms causing epileptic disorders. The detection of epileptiform discharges in the EEG is an important component in the diagnosis of epilepsy. In this study, we have proposed subspace-based methods to analyze and characterize epileptiform discharges in the form of 3-Hz spike and wave complex in patients with absence seizure. The variations in the shape of the EEG power spectra were examined in order to obtain medical information. These power spectra were then used to compare the applied methods in terms of their frequency resolution and the effects in determination of epileptic seizure. Global performance of the proposed methods was evaluated by means of the visual inspection of power spectral densities (PSDs). Graphical results comparing the performance of the proposed methods with that of the autoregressive techniques were given. The results demonstrate consistently superior performance of the proposed methods over the autoregressive ones.

Computer Simulation↗

Classification of EEG signals using neural network and logistic regression.

Epileptic seizures are manifestations of epilepsy. Careful analyses of the electroencephalograph (EEG) records can provide valuable insight and improved understanding of the mechanisms causing epileptic disorders. The detection of epileptiform discharges in the EEG is an important component in the diagnosis of epilepsy. As EEG signals are non-stationary, the conventional method of frequency analysis is not highly successful in diagnostic classification. This paper deals with a novel method of analysis of EEG signals using wavelet transform and classification using artificial neural network (ANN) and logistic regression (LR). Wavelet transform is particularly effective for representing various aspects of non-stationary signals such as trends, discontinuities and repeated patterns where other signal processing approaches fail or are not as effective. Through wavelet decomposition of the EEG records, transient features are accurately captured and localized in both time and frequency context. In epileptic seizure classification we used lifting-based discrete wavelet transform (LBDWT) as a preprocessing method to increase the computational speed. The proposed algorithm reduces the computational load of those algorithms that were based on classical wavelet transform (CWT). In this study, we introduce two fundamentally different approaches for designing classification models (classifiers) the traditional statistical method based on logistic regression and the emerging computationally powerful techniques based on ANN. Logistic regression as well as multilayer perceptron neural network (MLPNN) based classifiers were developed and compared in relation to their accuracy in classification of EEG signals. In these methods we used LBDWT coefficients of EEG signals as an input to classification system with two discrete outputs: epileptic seizure or non-epileptic seizure. By identifying features in the signal we want to provide an automatic system that will support a physician in the diagnosing process. By applying LBDWT in connection with MLPNN, we obtained novel and reliable classifier architecture. The comparisons between the developed classifiers were primarily based on analysis of the receiver operating characteristic (ROC) curves as well as a number of scalar performance measures pertaining to the classification. The MLPNN based classifier outperformed the LR based counterpart. Within the same group, the MLPNN based classifier was more accurate than the LR based classifier.

Adult↗

Electrocardiogram signals de-noising using lifting-based discrete wavelet transform.

This paper introduces an effective technique for the denoising of electrocardiogram (ECG) signals corrupted by nonstationary noises. The technique is based on a second generation wavelet transform and level-dependent threshold estimator. Here, wavelet coefficients of ECG signals were obtained with lifting-based wavelet filters. A lifting scheme is used to construct second-generation wavelets and is an alternative and faster algorithm for a classical wavelet transform. The overall denoising performance of our proposed method is considered in relation to several measuring parameters, including types of wavelet filters (Haar, Daubechies 4 (DB4), Daubechies 6 (DB6), Filter(9-7), and Cubic B-splines), thresholding method, and decomposition depth. Three different kinds of noise were considered in this work: muscle artifact noise, electrode motion artifact noise, and white noise. Global performance is evaluated by means of the signal-to-noise ratio and visual inspection. Numerical results comparing the performance of the proposed method with that of nonlinear filtering techniques (median filter) are given. The results demonstrate consistently superior denoising performance of the proposed method over median filtering.

Algorithms↗