PubMed Health⌕ Search

Biomedical subjects

Eric B Roesch

Publications and source records attributed to Eric B Roesch.

2 recordsLinked to original sources

Multiplexed genetic analysis using an expanded genetic alphabet.

BACKGROUND: All states require some kind of testing for newborns, but the policies are far from standardized. In some states, newborn screening may include genetic tests for a wide range of targets, but the costs and complexities of the newer genetic tests inhibit expansion of newborn screening. We describe the development and technical evaluation of a multiplex platform that may foster increased newborn genetic screening. METHODS: MultiCode PLx involves three major steps: PCR, target-specific extension, and liquid chip decoding. Each step is performed in the same reaction vessel, and the test is completed in approximately 3 h. For site-specific labeling and room-temperature decoding, we use an additional base pair constructed from isoguanosine and isocytidine. We used the method to test for mutations within the cystic fibrosis transmembrane conductance regulator (CFTR) gene. The developed test was performed manually and by automated liquid handling. Initially, 225 samples with a range of genotypes were tested retrospectively with the method. A prospective study used samples from >400 newborns. RESULTS: In the retrospective study, 99.1% of samples were correctly genotyped with no incorrect calls made. In the perspective study, 95% of the samples were correctly genotyped for all targets, and there were no incorrect calls. CONCLUSIONS: The unique genetic multiplexing platform was successfully able to test for 31 targets within the CFTR gene and provides accurate genotype assignments in a clinical setting.

Autoanalysis↗

Exploiting the enzymatic recognition of an unnatural base pair to develop a universal genetic analysis system.

BACKGROUND: With the invention of the DNA chip, genome-wide analysis is now a reality. Unfortunately, solid-phase detection systems such as the DNA chip suffer from a narrow range in quantification and sensitivity. Today the best methodology for sensitive, wide dynamic range quantification and genotyping of nucleic acids is real-time PCR. However, multiplexed real-time PCR technologies require complicated and costly design and manufacturing of separate detection probes for each new target. METHODS: We developed a novel real-time PCR technology that uses universal energy transfer probes constructed from An Expanded Genetic Information System (AEGIS) for both quantification and genotyping analyses. RESULTS: RNA quantification by reverse transcription-PCR was linear over four orders of magnitude for the simultaneous analysis of beta-actin messenger RNA and 18S ribosomal RNA. A single trial validation study of 176 previously genotyped clinical specimens was performed by endpoint analysis for factor V Leiden and prothrombin 20210A mutation detection. There was concordance for 173 samples between the genotyping results from Invader tests and the AEGIS universal energy transfer probe system for both factor V Leiden and prothrombin G20210A. Two prothrombin and one factor V sample gave indeterminate results (no calls). CONCLUSION: The AEGIS universal probe system allows for rapid development of PCR assays for nucleic acid quantification and genotyping.

Actins↗