PubMed Health⌕ Search

Biomedical subjects

Eric Bonneil

Publications and source records attributed to Eric Bonneil.

9 recordsLinked to original sources

aPKC-mediated phosphorylation regulates asymmetric membrane localization of the cell fate determinant Numb.

In Drosophila, the partition defective (Par) complex containing Par3, Par6 and atypical protein kinase C (aPKC) directs the polarized distribution and unequal segregation of the cell fate determinant Numb during asymmetric cell divisions. Unequal segregation of mammalian Numb has also been observed, but the factors involved are unknown. Here, we identify in vivo phosphorylation sites of mammalian Numb and show that both mammalian and Drosophila Numb interact with, and are substrates for aPKC in vitro. A form of mammalian Numb lacking two protein kinase C (PKC) phosphorylation sites (Numb2A) accumulates at the cell membrane and is refractory to PKC activation. In epithelial cells, mammalian Numb localizes to the basolateral membrane and is excluded from the apical domain, which accumulates aPKC. In contrast, Numb2A is distributed uniformly around the cell cortex. Mutational analysis of conserved aPKC phosphorylation sites in Drosophila Numb suggests that phosphorylation contributes to asymmetric localization of Numb, opposite to aPKC in dividing sensory organ precursor cells. These results suggest a model in which phosphorylation of Numb by aPKC regulates its polarized distribution in epithelial cells as well as during asymmetric cell divisions.

Amino Acid Sequence↗

Integrated microfluidic devices with enhanced separation performance: application to phosphoproteome analyses of differentiated cell model systems.

This work reports on the application of a microfluidic device integrating nanoscale LC to nanoelectrospray MS (nano-LC-chip-MS) for the analysis of complex protein digests. Peak profile analyses of more than 700 peptide ions, reproducibly detected across replicate nano-LC-chip-MS runs (n = 5), indicated that the system provided RSD values of 0.24% on retention time, +/- 30 ppm on m/z measurement and +/- 30% variation on intensity over three orders of magnitude. RP adsorbant media with different alkyl chains and particle size packed in both trapping and separation channels were investigated to improve the chromatographic performance of this system. A two-fold improvement in chromatographic peak capacity was achieved using microfluidic devices comprising a 5 mircrom C3 trap with 2.5 microm C18 trap separation channel compared to the traditional 5 microm C18 stationary phase. Enhanced sample selectivity for the identification of phosphopeptides was obtained by combining immobilized metal affinity media prior to peptide separation on the RP microfluidic device. This system was evaluated in the context of differential phosphoproteome analyses to identify changes in signaling events and protein expression of human monocytes following the administration of phorbol ester.

Animals↗

Improvement in peptide detection for proteomics analyses using NanoLC-MS and high-field asymmetry waveform ion mobility mass spectrometry.

Sensitive and selective detection of multiply charged peptide ions from complex tryptic digests was achieved using high-field asymmetric waveform ion mobility spectrometry (FAIMS) combined with nanoscale liquid chromatography-mass spectrometry (nanoLC-FAIMS-MS). The combination of FAIMS provided a marked advantage over conventional nanoLC-MS experiments by reducing the extent of chemical noise associated with singly charged ions and enhancing the overall population of detectable tryptic peptides. Such advantages were evidenced by a 6-12-fold improvement in signal-to-noise ratio measurements for a wide range of multiply charged peptide ions. An increase of 20% in the number of detected peptides compared to conventional nanoelectrospray was achieved by transmitting ions of different mobilities at high electric field vs low field while simultaneously recording each ion population in separate mass spectrometry acquisition channels. This method provided excellent reproducibility across replicate nanoLC-FAIMS-MS runs with more than 90% of all detected peptide ions showing less than 30% variation in intensity. The application of this technique in the context of proteomics research is demonstrated for the identification of trace-level proteins showing differential expression in U937 monocyte cell extracts following incubation with phorbol ester.

Animals↗

Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs.

The present investigation describes the analytical performances of a microfluidic device comprising an enrichment column, a reversed-phase separation channel, and a nanoelectrospray emitter embedded altogether in polyimide layers. This configuration minimizes transfer lines and connections and reduces postcolumn peak broadening and dead volumes. This compact and versatile modular nanoLC-chip system was interfaced to both ion trap and time-of-flight mass spectrometers, and its analytical potentials were evaluated in the context of proteomics applications. The figures of merit of this system in terms of peak capacity, reproducibility, sensitivity, and linear dynamic range of peptide detection were determined using tryptic digests of complex protein extracts including albumin- and immunoglobulin-depleted rat plasma samples. The analysis of peak profiles for more than 600 peptide ions reproducibly detected across replicate nanoLC-chip-MS runs (n = 10) indicated that this system provided good reproducibility of retention time and peak intensity with RSD values of less than 0.5 and 9.1%, respectively. Variation in peptide abundance as low as 2-fold changes was identified for spiked tryptic digests present at levels of 2-5 fmol in plasma samples. Sensitivity measurements were performed on dilution series of protein digests spiked into rat plasma samples and provided a detection limit of 1-5 fmol. The modular concept of the microfluidic systems also facilitated the integration of two-dimensional chromatography (strong cation exchange/C18) thereby increasing the sample loading and selectivity of the nanoLC-chip-MS system. The application of this integrated device was evaluated for complex rat plasma samples to compare the number of protein identifications obtained using one- and two-dimensional nanoLC-chip-MS/MS.

Biomarkers↗

Multiplex multidimensional nanoLC-MS system for targeted proteomic analyses.

The present work describes a dual-column and dual-sprayer LC-MS system for high-throughput proteomic analyses. This system consists of two precolumns for sample desalting and two analytical columns. Each column is terminated by a nanoelectrospray emitter mounted on a robotic arm enabling their sequential positioning in front of the sampling cone of the mass spectrometer. The effluent from each emitter is recorded in separate acquisition channels without detectable crosstalk. Gradient elution to both nanoLC columns is delivered by a single HPLC system via a flow splitter. The reproducibility of retention time and peak intensity of the present multiplex system were comparable to those obtainable using a single emitter configuration. Replicate injections of complex tryptic digests (n = 10) indicated that this system provided good reproducibility of retention time and peak intensity on both columns with RSD values of less than 0.9 and 18.6%, respectively. The application of this system is demonstrated for the monitoring of protein expression changes in U937 human monocyte cells with and without phorbol ester administration. Furthermore, we also demonstrated the use of this multiplex system in a 2-D LC configuration to increase sample loading and throughput for the analysis of biomarker samples of higher complexity. Variations in peptide abundance down to two-fold change were identified across salt fractions for spiked tryptic digests present at a level of 50 fmol in 1.5 microg of plasma samples.

Animals↗

Probing genetic variation and glycoform distribution in lectins of the Erythrina genus by mass spectrometry.

Six leguminous lectins from the seeds of plants of the Erythrina genus, namely E. caffra (ECafL), E. cristagalli (ECL), E. flabelliformis (EFL), E. lysistemon (ELysL), E. rubrinerva (ERL), and E. vespertilio (EVL), were examined to establish their sequence homology and to determine the structure and sites of attachment of their glycans. Tryptic digests of these lectins were analyzed by capillary electrophoresis coupled to electrospray mass spectrometry (CE-ESMS). Assignments were made by comparing the molecular masses of the observed tryptic peptides with those of Erythrina corallodendron lectin (ECorL), the sequence of which had been established previously. Glycan structure and genetic variations in the amino acid sequence were probed by tandem mass spectrometry. Small differences were found between the sequences of the various lectins examined and all of them exhibited C-terminal processing resulting in proteins with a C-terminal Asn residue. The major glycan of these glycoproteins was shown to be the heptasaccharide Man(3)XylFucGlcNAc(2), consistent with previous investigations on ECL and ECorL. A minor glycan heterogeneity was observed for most lectins examined except for that of ECafL and ECorL where an extra hexose residue was observed on the reducing GlcNAc residue of the heptasaccharide.

Amino Acid Sequence↗

N-Terminal ubiquitination of extracellular signal-regulated kinase 3 and p21 directs their degradation by the proteasome.

Extracellular signal-regulated kinase 3 (ERK3) is an unstable mitogen-activated protein kinase homologue that is constitutively degraded by the ubiquitin-proteasome pathway in proliferating cells. Here we show that a lysineless mutant of ERK3 is still ubiquitinated in vivo and requires a functional ubiquitin conjugation pathway for its degradation. Addition of N-terminal sequence tags of increasing size stabilizes ERK3 by preventing its ubiquitination. Importantly, we identified a fusion peptide between the N-terminal methionine of ERK3 and the C-terminal glycine of ubiquitin in vivo by tandem mass spectrometry analysis. These findings demonstrate that ERK3 is conjugated to ubiquitin via its free NH(2) terminus. We found that large N-terminal tags also stabilize the expression of the cell cycle inhibitor p21 but not that of substrates ubiquitinated on internal lysine residues. Consistent with this observation, lysineless p21 is ubiquitinated and degraded in a ubiquitin-dependent manner in intact cells. Our results suggests that N-terminal ubiquitination is a more prevalent modification than originally recognized.

Cell Line↗

Integration of solid-phase extraction membranes for sample multiplexing: application to rapid protein identification from gel-isolated protein extracts.

The present report describes the design and application of a dual sprayer system for high-throughput proteome analysis. This system comprises parallel solid-phase extraction cartridges used for preconcentration and desalting of proteolytic digests prior to nanoelectrospray mass spectrometry analyses. Tryptic peptides from in-gel digest of protein bands/spots are first adsorbed on styrene divinyl benzene membrane and subsequently eluted with a short plug of organic buffer prior to infusion to the mass spectrometer at a flow rate of typically 500 nL/min. Tryptic peptide eluting from the membrane are analyzed by the mass spectrometer by moving in turn each sprayer in front of the sampling orifice. Sequential injection, preconcentration and analyses of tryptic digests are typically achieved with a throughput of up to 3.5 min/sample and a detection limit of approximately 8-80 fmol per injection. Replicate injections of peptide mixtures indicated that reproducibility of peak areas ranged from relative standard deviations (RSD) of 1.1% to 4.5%. The application of this device is demonstrated for digests of gel-isolated proteins obtained from sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) separation of rat liver plasma membrane and from two-dimensional gel electrophoresis of total cell lysate extracts from human prostatic cancer cell.

Angiotensin I↗

Application of microfluidic devices to proteomics research: identification of trace-level protein digests and affinity capture of target peptides.

This report describes an integrated and modular microsystem providing rapid analyses of trace-level tryptic digests for proteomics applications. This microsystem includes an autosampler, a microfabricated device comprising a large channel (2.4 microl total volume), an array of separation channels, together with a low dead volume enabling the interface to nanoelectrospray mass spectrometry. The large channel of this microfluidic device provides a convenient platform to integrate C(18) reverse phase packing or other type of affinity media such as immobilized antibodies or immobilized metal affinity chromatography beads thus enabling affinity selection of target peptides prior to electrophoretic separation and mass spectrometry analyses on a quadrupole/time-of-flight instrument. Sequential injection, preconcentration, and separation of peptide standards and tryptic digests are achieved with a throughput of up to 12 samples/per h and a concentration detection limit of approximately 5 nM (25 fmol on chip). Replicate injections of peptide mixtures indicated that reproducibility of migration time was 1.2-1.8%, whereas relative standard deviation ranging from 9.2 to 11.8% are observed on peak heights. The application of this device for trace-level protein identification is demonstrated for two-dimensional gel spots obtained from extracts of human prostatic cancer cells (LNCap) using both peptide mass-fingerprint data base searching and on-line tandem mass spectrometry. Enrichment of target peptides prior to mass spectral analyses is achieved using c-myc-specific antibodies immobilized on protein G-Sepharose beads and facilitates the identification of antigenic peptides spiked at a level of 20 ng/ml in human plasma. Affinity selection is also demonstrated for gel-isolated protein bands where tryptic phosphopeptides are captured on immobilized metal affinity chromatography beads and subsequently separated and characterized on this microfluidic system.

Amino Acid Sequence↗