PubMed Health⌕ Search

Biomedical subjects

Eric Buel

Publications and source records attributed to Eric Buel.

8 recordsLinked to original sources

Simultaneous determination of total human and male DNA using a duplex real-time PCR assay.

A single duplex assay to determine both the amount of total human DNA and the amount of male DNA in a forensic sample has been developed. This assay is based on TaqMan technology and uses the multicopy Alu sequence to quantitate total human DNA and the multicopy DYZ5 sequence to quantitate Y chromosomal (male) DNA. The assay accepts a wide concentration range of input DNA (2 muL of 64 ng/microL to 0.5 pg/microL), and also allows detection of PCR failure. The PCR product sizes Alu (127 bp) and DYZ5 (137bp) approximate that of the smaller short tandem repeats (STRs) which should make the assay predictive of STR success with degraded DNA. The assay was optimized for probe/primer concentrations and BSA addition and validated on its reproducibility, on its human specificity, on its nonethnic variability, for artificial mixtures and adjudicated casework, for the effect of inhibitors and for state of DNA degradation. This assay should prove very usual in forensic analyses because knowing the relative amounts of male versus female DNA can allow the examiner to decide which samples may yield the most probative value in a case or direct the samples to methods that would yield the greatest information.

Alu Elements↗

An Alu-based, MGB Eclipse real-time PCR method for quantitation of human DNA in forensic samples.

The forensic community needs quick, reliable methods to quantitate human DNA in crime scene samples to replace the laborious and imprecise slot blot method. A real-time PCR based method has the possibility of allowing development of a faster and more quantitative assay. Alu sequences are primate-specific and are found in many copies in the human genome, making these sequences an excellent target or marker for human DNA. This paper describes the development of a real-time Alu sequence-based assay using MGB Eclipse primers and probes. The advantages of this assay are simplicity, speed, less hands-on-time and automated quantitation, as well as a large dynamic range (128 ng/microL to 0.5 pg/microL).

Alu Elements↗

Forensic DNA typing by capillary electrophoresis using the ABI Prism 310 and 3100 genetic analyzers for STR analysis.

DNA typing with short tandem repeat (STR) markers is now widely used for a variety of applications including human identification. Capillary electrophoresis (CE) instruments, such as the ABI Prism 310 and ABI 3100 Genetic Analyzers, are the method of choice for many laboratories performing STR analysis. This review discusses issues surrounding sample preparation, injection, separation, detection, and interpretation of STR results using CE systems. Requirements for accurate typing of STR alleles are considered in the context of what future analysis platforms will need to increase sample throughput and ease of use.

Electrophoresis, Capillary↗

Quantification of DNA in forensic samples.

Quantification of DNA in a forensic sample is of major importance for proper DNA amplification and STR profiling. Several methods have been developed to quantify DNA, from basic UV spectrometry, through gel-based techniques, to dye staining, blotting techniques, and, very recently, DNA amplification methods (polymerase chain reaction, PCR). Early techniques simply measured total DNA, but newer techniques can specifically measure human DNA while excluding non-human DNA (foodstuff, animal, or bacterial contamination). These newer assays can be faster and less expensive than traditional methods, making them ideal for the busy forensic laboratory. This paper reviews classic and newer quantification techniques and presents methods recently developed by the authors on the basis of PCR of Alu sequences.

Animals↗

Using resolution calculations to assess changes in capillary electrophoresis run parameters.

Capillary electrophoresis is widely used in the forensic community for the analysis of Short Tandem Repeat DNA. The CE system used in most forensic laboratories allows the user to modify standard operational protocols to accommodate some samples that fall outside of interpretational guidelines. We have made operational changes and monitored system resolution and the ability of the software to identify alleles as a result of these modifications. Increased amount of amplified product in the injection preparation, lengthened injection times or repeated injections of the same sample were all investigated along with variations in run voltages. Certain protocol modifications offer some advantages to the analysis of STRs and may allow the analyst to avoid extraction of additional portions of crime scene samples to achieve interpretable results.

Alleles↗

Development of an Alu-based, QSY 7-labeled primer PCR method for quantitation of human DNA in forensic samples.

Determining the amount of human DNA extracted from a crime scene sample is an important step in DNA profiling. The forensic community relies almost entirely upon a technique (slot blot) to quantitate human DNA that is imprecise, time consuming, and labor intensive. This paper describes the development of a new technique based on PCR amplification of a repetitive Alu sequence. Specific primers were used to amplify a 124-bp fragment of Alu sequence; amplification was detected by SYBR Green I staining in a fluorescent plate reader. To reduce background in the plate reader assay, QSY-7 labeled primers were utilized. The assay was tested on animal DNAs, human blood spots, mock crime samples, and degraded DNA in comparison with the slot blot technique. The QSY Alu assay has a dynamic range of 10 ng to 10 pg, and is sensitive, specific, fast, quantitative, and comparable in cost to the slot blot assay.

Alu Elements↗

Development of an Alu-based, real-time PCR method for quantitation of human DNA in forensic samples.

Determining the amount of human DNA extracted from a crime scene sample is an important step in DNA profiling. The forensic community relies almost entirely upon a technique (slot blot) to quantitate human DNA that is imprecise, time consuming, and labor intensive. We have previously described a method for quantitation of human DNA based on PCR amplification of a repetitive Alu sequence that uses a fluorescence plate reader. This manuscript describes and validates a variation of this assay using real-time PCR and SYBR Green I for quantitation. The advantages of the real-time assay over the plate reader assay are: reduced hands-on time, lower assay cost, and a greater dynamic range. The main disadvantage is the cost of the real-time instrument. However, for those forensic laboratories with access to a real-time instrument, this Alu-based assay has a dynamic range of 16 ng to 1 pg, is sensitive, specific, fast, quantitative, and uses only 2 microL of sample.

Alu Elements↗

Validation of a 16-locus fluorescent multiplex system.

STR multiplexes have been indispensable for the efficient genotyping of forensic samples. The PowerPlex 16 System contains the coreCODIS loci, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, THOI, TPOX, vWA, the sex determinant locus, amelogenin, and two pentanucleotide STR loci, Penta D and Penta E. This multiplex satisfies the locus requirements for most national databases and is the most efficient currently available system due to its single PCR amplification. To provide the groundwork for judicial acceptance, including the publication of primer sequences, and to evaluate laboratory-to-laboratory variation, a developmental validation for casework on this commercially available system was performed in 24 laboratories and produced the following conclusions. Amplification was reliable on a variety of thermal cyclers and product could be analyzed on either an ABI PRISM 310 Genetic Analyzer or an ABI PRISM 377 DNA Sequencer. Genotyping using single source samples was consistent between 0.25 and 2 ng of input DNA template with a few laboratories obtaining complete genotypes at 0.0625 ng. However, heterozygote allele imbalance (<60% peak height balance) caused by stochastic effects was observed at a rate of 13% with 0.125 ng DNA and 22% at 0.0625 ng DNA. Mixture analyses were done using a total of 1 ng of DNA template. Most alleles were detected in mixtures of 4 to 1 and some minor alleles were detected in mixtures of 19 to 1. Optimum amplification cycle number was dependent on the sensitivity of the detection instrument used and could also be adjusted to accommodate larger amounts of DNA on solid supports such as FTA paper. Reaction conditions including volume, annealing temperature, and concentrations of primer, AmpliTaq Gold, and magnesium were shown to be optimal yet robust enough to withstand moderate variations without affecting genotype analysis. Environmental, matrix and standard source analyses revealed an ability to obtain complete genotypes in all sample types except those exposed to 80 degrees C for 12-48 days. Finally, comparison of genotype results from the PowerPlex 16 System with other commercially available systems on non-probative reference and forensic samples showed consistent results.

Alleles↗