PubMed Health⌕ Search

Biomedical subjects

Eric Fleury

Publications and source records attributed to Eric Fleury.

2 recordsLinked to original sources

Optimizing sequential biventricular pacing using radionuclide ventriculography.

BACKGROUND: Biventricular pacemakers are usually programmed with the default setting of synchronous biventricular pacing, although the ventricles may be paced sequentially. Whether this parameter is important for optimizing resynchronization therapy is not clear. OBJECTIVES: The purpose of this study was to investigate whether sequential pacing acutely improves left ventricular ejection fraction (LVEF) and dyssynchrony and to assess the feasibility of nuclear ventriculography for device optimization. METHODS: Twenty-seven patients implanted with a biventricular pacemaker or implantable cardioverter-defibrillator for heart failure were studied. LVEF was measured using planar radionuclide ventriculography during simultaneous biventricular pacing and during sequential pacing at four different interventricular intervals ranging from LV-40 (preexciting the left ventricle by 40 ms) to LV+40 (preexciting the right ventricle). Interventricular and intraventricular dyssynchrony were analyzed by phase analysis at each setting. RESULTS: There was great heterogeneity in individual response to VV interval programming. Twenty-four of 27 patients (89%) had significant changes (both favorable and unfavorable) in LVEF at different interventricular delays, with variations of up to 10% in absolute terms. Simultaneous biventricular pacing yielded maximal LVEF in 9 of 27 patients (33%), with a relative increase in LVEF of 18 +/- 14% by optimized sequential pacing in the remaining patients. Interventricular dyssynchrony varied significantly, with least dyssynchrony at the LV-20 setting (P = .024). There were no significant differences in intraventricular dyssynchrony at the different settings. CONCLUSION: Programming VV intervals has considerable impact on LVEF. However, there is a great degree of variation between patients in response to these settings, requiring individual assessment for device optimization.

Aged↗

Normal values and within-subject variability of cardiac I-123 MIBG scintigraphy in healthy individuals: implications for clinical studies.

BACKGROUND: Although several myocardial iodine 123 metaiodobenzylguanidine (MIBG) indices are increasingly used to detect alterations in myocardial sympathetic activity in various forms of cardiac pathology, published measurements of normal values and within-subject variability are lacking. METHODS AND RESULTS: Twenty-five healthy volunteers underwent planar and single photon emission computed tomography (SPECT) imaging. Heart-mediastinum ratio (H/M) and myocardial washout were calculated from planar images comparing three different methods for the assessment of myocardial activity: (1) global region over the myocardium (cavity included), (2) global region over the myocardium (cavity excluded), and (3) fixed small myocardial region. Segmental (relative) uptake and washout were assessed by SPECT. For all MIBG indices, the interindividual variation was the lowest for methods 1 and 2. In SPECT this variation was low for relative segmental uptake compared with washout. In 9 subjects a second MIBG scintigraphy was performed after 3 months. The within-subject variability of H/M and washout assessed by planar methods 1 and 2 was 5%, whereas it was approximately 9% for planar method 3. For relative segmental uptake from SPECT, this variability was 5%. CONCLUSION: MIBG H/M (planar) and relative segmental uptake (SPECT) show a low interindividual and within-subject variability. This enables the detection of small (regional) variations in myocardial sympathetic nervous function, especially to monitor the effect of therapeutic interventions in patients with various cardiac diseases.

3-Iodobenzylguanidine↗