PubMed Health⌕ Search

Biomedical subjects

Eric G Poon

Publications and source records attributed to Eric G Poon.

At least 19 recordsLinked to original sources

Correlates of electronic health record adoption in office practices: a statewide survey.

OBJECTIVE: Despite emerging evidence that electronic health records (EHRs) can improve the efficiency and quality of medical care, most physicians in office practice in the United States do not currently use an EHR. We sought to measure the correlates of EHR adoption. DESIGN: Mailed survey to a stratified random sample of all medical practices in Massachusetts in 2005, with one physician per practice randomly selected for survey. MEASUREMENTS: EHR adoption rates. RESULTS: The response rate was 71% (1345/1884). Overall, while 45% of physicians were using an EHR, EHRs were present in only 23% of practices. In multivariate analysis, practice size was strongly correlated with EHR adoption; 52% of practices with 7 or more physicians had an EHR, as compared with 14% of solo practices (adjusted odds ratio, 3.66; 95% confidence interval, 2.28-5.87). Hospital-based practices (adjusted odds ratio, 2.44; 95% confidence interval, 1.53-3.91) and practices that teach medical students or residents (adjusted odds ratio, 2.30; 95% confidence interval, 1.60-3.31) were more likely to have an EHR. The most frequently cited barriers to adoption were start-up financial costs (84%), ongoing financial costs (82%), and loss of productivity (81%). CONCLUSIONS: While almost half of physicians in Massachusetts are using an EHR, fewer than one in four practices in Massachusetts have adopted EHRs. Adoption rates are lower in smaller practices, those not affiliated with hospitals, and those that do not teach medical students or residents. Interventions to expand EHR use must address both financial and non-financial barriers, especially among smaller practices.

Attitude to Computers↗

Medication dispensing errors and potential adverse drug events before and after implementing bar code technology in the pharmacy.

BACKGROUND: Many dispensing errors made in hospital pharmacies can harm patients. Some hospitals are investing in bar code technology to reduce these errors, but data about its efficacy are limited. OBJECTIVE: To evaluate whether implementation of bar code technology reduced dispensing errors and potential adverse drug events (ADEs). DESIGN: Before-and-after study using direct observations. SETTING: Hospital pharmacy at a 735-bed tertiary care academic medical center. INTERVENTION: A bar code-assisted dispensing system was implemented in 3 configurations. In 2 configurations, all doses were scanned once during the dispensing process. In the third configuration, only 1 dose was scanned if several doses of the same medication were being dispensed. MEASUREMENTS: Target dispensing errors, defined as dispensing errors that bar code technology was designed to address, and target potential ADEs, defined as target dispensing errors that can harm patients. RESULTS: In the pre- and post-bar code implementation periods, the authors observed 115,164 and 253,984 dispensed medication doses, respectively. Overall, the rates of target potential ADEs and all potential ADEs decreased by 74% and 63%, respectively. Of the 3 configurations of bar code technology studied, the 2 configurations that required staff to scan all doses had a 93% to 96% relative reduction in the incidence of target dispensing errors (P < 0.001) and 86% to 97% relative reduction in the incidence of potential ADEs (P < 0.001). However, the configuration that did not require scanning of every dose had only a 60% relative reduction in the incidence of target dispensing errors (P < 0.001) and an increased (by 2.4-fold) incidence of target potential ADEs (P = 0.014). There were several potentially life-threatening ADEs involving intravenous dopamine and intravenous heparin in that configuration. LIMITATIONS: The authors used surrogate outcomes; did not mask assessors to the purpose of study; and excluded the controlled substance fill process (a process with low error rates at baseline) from the study, which may bias the combined decrease in error rates toward a larger magnitude. CONCLUSIONS: The overall rates of dispensing errors and potential ADEs substantially decreased after implementing bar code technology. However, the technology should be configured to scan every dose during the dispensing process.

Drug Labeling↗

Assessing the level of healthcare information technology adoption in the United States: a snapshot.

BACKGROUND: Comprehensive knowledge about the level of healthcare information technology (HIT) adoption in the United States remains limited. We therefore performed a baseline assessment to address this knowledge gap. METHODS: We segmented HIT into eight major stakeholder groups and identified major functionalities that should ideally exist for each, focusing on applications most likely to improve patient safety, quality of care and organizational efficiency. We then conducted a multi-site qualitative study in Boston and Denver by interviewing key informants from each stakeholder group. Interview transcripts were analyzed to assess the level of adoption and to document the major barriers to further adoption. Findings for Boston and Denver were then presented to an expert panel, which was then asked to estimate the national level of adoption using the modified Delphi approach. We measured adoption level in Boston and Denver was graded on Rogers' technology adoption curve by co-investigators. National estimates from our expert panel were expressed as percentages. RESULTS: Adoption of functionalities with financial benefits far exceeds adoption of those with safety and quality benefits. Despite growing interest to adopt HIT to improve safety and quality, adoption remains limited, especially in the area of ambulatory electronic health records and physician-patient communication. Organizations, particularly physicians' practices, face enormous financial challenges in adopting HIT, and concerns remain about its impact on productivity. CONCLUSION: Adoption of HIT is limited and will likely remain slow unless significant financial resources are made available. Policy changes, such as financial incentivesto clinicians to use HIT or pay-for-performance reimbursement, may help health care providers defray upfront investment costs and initial productivity loss.

Attitude of Health Personnel↗

How many hospital pharmacy medication dispensing errors go undetected?

BACKGROUND: Hospital pharmacies dispense large numbers of medication doses for hospitalized patients. A study was conducted at an academic tertiary care hospital to characterize the incidence and severity of medication dispensing errors in a hospital pharmacy. METHODS: Direct observation of dispensing processes was undertaken to determine presence of errors with review by a physician panel to determine severity. RESULTS: A total of 140,755 medication doses filled by pharmacy technicians were observed during a seven-month period, and 3.6% (5075) contalned errors. The hospital pharmacist detected only 79% of these errors during routine verification; thus, 0.75% of doses filled would have left the phannacy with undetected errors. Overall, 23.5% of undetected errors were potential adverse drug events (ADEs), of which 28% were serious and 0.8% were life threatening. The most common potential ADEs were incorrect medications (36%), incorrect strength (35%), and incorrect dosage form (21%). DISCUSSION: Given the volume of medications dispensed, even a low rate of drug distribution process translates into a large number of errors with potential to harm patients. Pharmacy distribution systems require further process redesign to achieve the highest possible level of safety and reliability.

Academic Medical Centers↗

Design and implementation of a web-based patient portal linked to an ambulatory care electronic health record: patient gateway for diabetes collaborative care.

BACKGROUND: Despite the availability of expert guidelines and widespread diabetes quality improvement efforts, care of patients with diabetes remains suboptimal. Two key barriers to care that may be amenable to informatics-based interventions include (1) lack of patient engagement with therapeutic care plans and (2) lack of medication adjustment by physicians ("clinical inertia") during clinical encounters. METHODS: The authors describe the conceptual framework, design, implementation, and analysis plan for a diabetes patient web-portal linked directly to the electronic health record (EHR) of a large academic medical center via secure Internet access designed to overcome barriers to effective diabetes care. RESULTS: Partners HealthCare System (Boston, MA), a multi-hospital health care network comprising several thousand physicians caring for over 1 million individual patients, has developed a comprehensive patient web-portal called Patient Gateway that allows patients to interact directly with their EHR via secure Internet access. Using this portal, a specific diabetes interface was designed to maximize patient engagement by importing the patient's current clinical data in an educational format, providing patient-tailored decision support, and enabling the patient to author a "Diabetes Care Plan." The physician view of the patient's Diabetes Care Plan was designed to be concise and to fit into typical EHR clinical workflow. CONCLUSIONS: We successfully designed and implemented a Diabetes Patient portal that allows direct interaction with our system's EHR. We are assessing the impact of this advanced informatics tool for collaborative diabetes care in a clinic-randomized controlled trial among 14 primary care practices within our integrated health care system.

Ambulatory Care↗

The costs of a national health information network.

BACKGROUND: The use of information technology may result in a safer and more efficient health care system. However, consensus does not exist about the structure or costs of a national health information network (NHIN). OBJECTIVES: To describe the potential structure and estimate the costs of an NHIN. DESIGN: Cost estimates of an NHIN model developed by an expert panel. SETTING: U.S. health care system. MEASUREMENTS: An expert panel estimated the existing and the expected prevalence in 5 years of critical information technology functionalities. They then developed a model of an achievable NHIN by defining key providers, functionalities, and interoperability functions. By using these data and published cost estimates, the authors determined the cost of achieving this model NHIN in 5 years given the current state of information technology infrastructure. RESULTS: To achieve an NHIN would cost 156 billion dollars in capital investment over 5 years and 48 billion dollars in annual operating costs. Approximately two thirds of the capital costs would be required for acquiring functionalities and one third for interoperability. Ongoing costs would be more evenly divided between functionality and interoperability. If the current trajectory continues, the health care system will spend 24 billion dollars on functionalities over the next 5 years or about one quarter of the cost for functionalities of a model NHIN. LIMITATIONS: Because of a lack of primary data, the authors relied on expert estimates. CONCLUSIONS: While an NHIN will be expensive, 156 billion dollars is equivalent to 2% of annual health care spending for 5 years. Assessments such as this one may assist policymakers in determining the level of investment that the United States should make in an NHIN.

Health Expenditures↗

Patient safety concerns arising from test results that return after hospital discharge.

BACKGROUND: Failure to relay information about test results pending when patients are discharged from the hospital may pose an important patient-safety problem. Few data are available on the epidemiology of test results pending at discharge or on physician awareness of these results. OBJECTIVE: To determine the prevalence, characteristics, and physician awareness of potentially actionable laboratory and radiologic test results returning after hospital discharge. DESIGN: Cross-sectional study. SETTING: Two tertiary care academic hospitals. PATIENTS: 2644 consecutive patients discharged from hospitalist services from February to June 2004. MEASUREMENTS: The main outcomes were the prevalence and characteristics of potentially actionable test results returning after hospital discharge, awareness of these results by inpatient and primary care physicians, and satisfaction of inpatient physicians with current systems for follow-up on test results. The authors prospectively collected data on test results pending at the time of discharge and, as results returned after discharge, surveyed hospitalists, junior residents, and primary care physicians about those results that were potentially actionable according to a physician-reviewer. RESULTS: A total of 1095 patients (41%) had 2033 test results return after discharge. Of these results, 191 (9.4% [95% CI, 8.0% to 11.0%]) were potentially actionable. Surveys were sent regarding 155 results, and 105 responses were returned. Of the 105 results in the surveys with responses, physicians had been unaware of 65 (61.6% [CI, 51.3% to 70.9%]); of these 65, they agreed with physician-reviewers that 24 (37.1% [CI, 25.7% to 50.2%]) were actionable and 8 (12.6% [CI, 6.4% to 23.3%]) required urgent action. Inpatient physicians were dissatisfied with their systems for following up on test results returning after discharge. LIMITATIONS: The authors were unable to determine whether physicians' lack of awareness of test results returning after discharge was associated with adverse outcomes. CONCLUSIONS: Many patients are discharged from hospitals with test results still pending, and physicians are often unaware of potentially actionable test results returning after discharge. Further work is needed to design better follow-up systems for test results returning after hospital discharge.

Clinical Laboratory Techniques↗

Using qualitative studies to improve the usability of an EMR.

The adoption of electronic medical records (EMRs) and user satisfaction are closely associated with the system's usability. To improve the usability of a results management module of a widely deployed web-based EMR, we conducted two qualitative studies that included multiple focus group and field study sessions. Qualitative research can help focus attention on user tasks and goals and identify patterns of care that can be visualized through task modeling exercises. Findings from both studies raised issues with the amount and organization of information in the display, interference with workflow patterns of primary care physicians, and the availability of visual cues and feedback. We used the findings of these studies to recommend design changes to the user interface of the results management module.

Attitude to Computers↗

Issues and initiatives in the testing process in primary care physician offices.

BACKGROUND: Errors occur frequently in management of the testing process in primary care physicians' offices. These errors may result in significant harm to patients and lead to inefficient practice. Important issues are summarized for primary care clinicians and their offices toconsider in improving the management of the testing processes. METHODS: To identify published efforts to improve management of the testing process, a literature search was performed and the references from the identified articles were checked for additional studies. Descriptive studies, expert opinion pieces, and controlled trials were all included. Unpublished results of ongoing studies in laboratory testing errors in primary care practice are presented. RESULTS: A conceptual model of the testing process was developed, with identified general and specific errors that occur in the testing process. On the basis largely of descriptive studies, ways are described to reduce testing process errors and the harm resulting from these errors. CONCLUSIONS: Standardization of processes, computerized test tracking systems (especially those embedded in electronic medical records), and attention to human factors issues are likely to reduce errors and harm. These ideas need confirmation in well-designed randomized trials and quality improvement initiatives.

Communication↗

Outpatient prescribing errors and the impact of computerized prescribing.

BACKGROUND: Medication errors are common among inpatients and many are preventable with computerized prescribing. Relatively little is known about outpatient prescribing errors or the impact of computerized prescribing in this setting. OBJECTIVE: To assess the rates, types, and severity of outpatient prescribing errors and understand the potential impact of computerized prescribing. DESIGN: Prospective cohort study in 4 adult primary care practices in Boston using prescription review, patient survey, and chart review to identify medication errors, potential adverse drug events (ADEs) and preventable ADEs. PARTICIPANTS: Outpatients over age 18 who received a prescription from 24 participating physicians. RESULTS: We screened 1879 prescriptions from 1202 patients, and completed 661 surveys (response rate 55%). Of the prescriptions, 143 (7.6%; 95% confidence interval (CI) 6.4% to 8.8%) contained a prescribing error. Three errors led to preventable ADEs and 62 (43%; 3% of all prescriptions) had potential for patient injury (potential ADEs); 1 was potentially life-threatening (2%) and 15 were serious (24%). Errors in frequency (n=77, 54%) and dose (n=26, 18%) were common. The rates of medication errors and potential ADEs were not significantly different at basic computerized prescribing sites (4.3% vs 11.0%, P=.31; 2.6% vs 4.0%, P=.16) compared to handwritten sites. Advanced checks (including dose and frequency checking) could have prevented 95% of potential ADEs. CONCLUSIONS: Prescribing errors occurred in 7.6% of outpatient prescriptions and many could have harmed patients. Basic computerized prescribing systems may not be adequate to reduce errors. More advanced systems with dose and frequency checking are likely needed to prevent potentially harmful errors.

Adult↗

Workflow analysis in primary care: implications for EHR adoption.

Within busy practice settings, it is difficult to provide adequate provider training on evolving electronic health record (EHR) functionality. As a result, providers may not reap the full benefits of EHR. This poster presents a systematic workflow study conducted to enhance the adoption of advanced EHR features. This study led us to develop new adoption and training strategies, which resulted in statistically significant (p<0.03) improvement in the adoption of advanced results management features.

Computer User Training↗

Primary care clinician attitudes towards ambulatory computerized physician order entry.

Ambulatory computerized physician order entry (ACPOE) represents one strategy to improve physician ordering practices, compliance with guidelines, and patient safety. We surveyed primary care physicians (PCPs) regarding attitudes towards ACPOE and its various features. Most PCPs did not have systems for tracking test results and were concerned about missed tests. However, there was concern that ACPOE might be time consuming, and only one-third of PCPs felt that ACPOE features would be very useful. Speed and workflow issues will be important contributors to the success of ACPOE. In addition, physician buy-in to the utility of its various features will need to be strengthened.

Ambulatory Care Information Systems↗

Effect of bar-code technology on the incidence of medication dispensing errors and potential adverse drug events in a hospital pharmacy.

We performed a direct observation prepost study to evaluate the impact of barcode technology on medication dispensing errors and potential adverse drug events in the pharmacy of a tertiary-academic medical center. We found that barcode technology significantly reduced the rate of target dispensing errors leaving the pharmacy by 85%, from 0.37% to 0.06%. The rate of potential adverse drug events (ADEs) due to dispensing errors was also significantly reduced by 63%, from 0.19%to 0.069%. In a 735-bed hospital where 6 million doses of medications are dispensed per year, this technology is expected to prevent about 13,000 dispensing errors and 6,000 potential ADEs per year.

Clinical Pharmacy Information Systems↗

"I wish I had seen this test result earlier!": Dissatisfaction with test result management systems in primary care.

BACKGROUND: Failure to review and follow up on outpatient test results in a timely manner represents a patient safety and malpractice concern. Therefore, we sought to identify problems in current test result management systems and possible ways to improve these systems. METHODS: We surveyed 262 physicians working in 15 internal medicine practices affiliated with 2 large urban teaching hospitals (response rate, 64%). We asked physicians about systems they used and the amount of time they spent managing test results. We asked them to report delays in reviewing test results and their overall satisfaction with their management of test results. We also asked physicians to rate features they would find useful in a new test result management system. RESULTS: Overall, 83% of respondents reported at least 1 delay in reviewing test results during the previous 2 months. Despite reporting that they spent on average 74 minutes per clinical day managing test results, only 41% of physicians reported being satisfied with how they managed test results. Satisfaction was associated with fewer self-reported delays in reviewing test results. Physicians who actively tracked their test orders to completion were also more likely to be satisfied. The most highly desired features of a test result management system were tools to help physicians generate result letters to patients, prioritize their workflow, and track test orders to completion. CONCLUSIONS: Delays in test result review are common, and many physicians are not satisfied with how they manage test results. Tools to improve test result management in office practices need to improve workflow efficiency and track test orders to completion.

Adult↗

Communication factors in the follow-up of abnormal mammograms.

OBJECTIVE: To identify the communication factors that are significantly associated with appropriate short-term follow-up of abnormal mammograms. DESIGN: Prospective longitudinal study involving medical record review and patient survey. SETTING: Ten academically affiliated ambulatory medical practices in the Boston metropolitan area. PARTICIPANTS: One hundred twenty-six women with abnormal mammograms requiring short-term (6 months) follow-up imaging. MEASUREMENTS: Proportion of women in the study who received appropriate follow-up care. RESULTS: Eighty-one (64%) of the women with abnormal mammograms requiring short-term follow-up imaging received the appropriate follow-up care. After adjusting for patients' age and insurance status, 2 communication factors were found to be independently associated with the delivery of appropriate follow-up care: 1). physicians' documentation of a follow-up plan in the medical record (adjusted odds ratio, 2.79; 95% confidence interval, 1.11 to 6.98; P =.029); and 2). patients' understanding of the need for follow-up (adjusted odds ratio, 3.86; 95% confidence interval, 1.50 to 9.96; P =.006). None of the patients' clinical or psychological characteristics were associated with the delivery of appropriate follow-up care. CONCLUSIONS: Follow-up care for women with abnormal mammograms requiring short-term follow-up imaging is suboptimal. Documentation of the follow-up plan by the physician and understanding of the follow-up plan by the patient are important factors that are correlated with the receipt of appropriate follow-up care for these women. Interventions designed to improve the quality of result follow-up in the outpatient setting should address these issues in patient-doctor communication.

Breast Diseases↗

Primary care clinician attitudes towards electronic clinical reminders and clinical practice guidelines.

Compliance with outpatient practice guidelines is low and clinical reminders have had variable success in improving adherence rates. We surveyed primary care physicians (PCPs) regarding practice guidelines and the perceived utility of electronic reminders for both routine health maintenance (HM) items and chronic disease management. Most PCPs preferred receiving reminders in an electronic format rather than a paper format. Electronic reminders were felt to be more useful for HM items than for diabetes management. The majority of clinicians felt that electronic reminders significantly improved overall health care quality.

Attitude of Health Personnel↗