PubMed Health⌕ Search

Biomedical subjects

Eric J Mozdy

Publications and source records attributed to Eric J Mozdy.

2 recordsLinked to original sources

Functional GPCR microarrays.

This paper describes G-protein-coupled receptor (GPCR) microarrays on porous glass substrates and functional assays based on the binding of a europium-labeled GTP analogue. The porous glass slides were made by casting a glass frit on impermeable glass slides and then coating with gamma-aminopropyl silane (GAPS). The emitted fluorescence was captured on an imager with a time-gated intensified CCD detector. Microarrays of the neurotensin receptor 1, the cholinergic receptor muscarinic 2, the opioid receptor mu, and the cannabinoid receptor 1 were fabricated by pin printing. The selective agonism of each of the receptors was observed. The screening of potential antagonists was demonstrated using a cocktail of agonists. The amount of activation observed was sufficient to permit determinations of EC50 and IC50. Such microarrays could potentially streamline drug discovery by helping integrate primary screening with selectivity and safety screening without compromising the essential functional information obtainable from cellular assays.

Drug Evaluation, Preclinical↗

Self-referencing a single waveguide grating sensor in a micron-sized deep flow chamber for label-free biomolecular binding assays.

In order to allow the design of increasingly sensitive label-free biosensors, compensation of environmental fluctuations is emerging as the dominant hurdle. The system and technique presented here utilize a unique combination of microfluidics, optical instrumentation, and image processing to provide a reference signal for each label-free biomolecular binding assay. Moreover, this reference signal is generated from the same sensor used to detect the biomolecular binding events. In this manner, the reference signal and the binding signal share nearly all common-mode noise sources (temperature, pressure, vibration, etc.) and their subtraction leaves the purest binding signal possible. Computational fluid dynamic simulations have been used to validate the flow behavior and thermal characteristics of the fluids inside the sensing region. This system has been demonstrated in simple bulk refractive index tests, as well as small molecule (biotin/streptavidin) binding experiments. The ability to perform not only simple binding but also control experiments has been discussed, indicating the wide applicability of the technique.

Biotin↗