PubMed Health⌕ Search

Biomedical subjects

Eric K Birks

Publications and source records attributed to Eric K Birks.

3 recordsLinked to original sources

Exercise-induced pulmonary hemorrhage.

EIPH is a condition affecting virtually all horses during intense exercise worldwide. The hemorrhage originates from the pulmonary vasculature and is distributed predominantly bilaterally in the dorsocaudal lung lobes. As the condition progresses, the lung abnormalities extend cranially along the dorsal portions of the lung. An inflammatory response occurs in association with the hemorrhage and may contribute to the chronic sequela. Although conflicting opinions exist as to its affect on performance, it is a syndrome that is thought to increase in severity with age. The most commonly performed method to diagnose EIPH at the present time is endoscopy of the upper airway alone or in combination with tracheal wash analysis for the presence of erythrocytes and hemosiderophages. Because horses may not bleed to the same extent every time and the bleeding may originate from slightly different locations, these diagnostic procedures may not be extremely sensitive or quantitative. At this time, there is no treatment that is considered a panacea, and the currently allowed treatments have not proven to be effective in preventing EIPH. Future directions for therapeutic intervention may need to include limiting inflammatory responses to blood remaining within the lungs after EIPH.

Animals↗

Quantification of clenbuterol in equine plasma, urine and tissue by liquid chromatography coupled on-line with quadrupole time-of-flight mass spectrometry.

Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.

Adrenergic beta-Agonists↗

Cardiac output technologies with special reference to the horse.

Critical illness, anesthesia, primary cardiovascular disease, and exercise may result in marked hemodynamic alterations. Measuring cardiac output (CO) is central to defining these alterations for both clinician and researcher. In the past 10 years, several new methods of measuring CO have been developed for the human medical market. Some of these methods are now validated in the horse and are in clinical use. The Fick method has been used in equine research for more than a century. It depends on simultaneous measurement of mixed venous (pulmonary arterial) and peripheral arterial oxygen content and oxygen uptake by the lungs. The technique is technically demanding, which restricts its clinical use. Indicator dilution techniques, with indocyanine green, cold (thermodilution), or lithium as the marker, have also been widely used in the horse. The indocyanine technique is cumbersome, and thermodilution requires right heart catheterization, which is not a benign procedure, making both of these methods less than ideal for clinical use. Lithium dilution requires catheterization of a peripheral artery and a jugular vein. It has recently been validated in anesthetized adult horses and neonatal foals. Doppler echocardiography is a noninvasive ultrasound-based technique. More accurate measurements are obtained with transesophageal than with transthoracic measurements; however, both methods require considerable technical expertise. Bioimpedance and pulse contour analysis are 2 new methods that have yet to be validated in the horse. With the currently available technology, lithium dilution appears to be the method of measuring CO best suited to the equine clinic.

Animals↗