PubMed Health⌕ Search

Biomedical subjects

Eric R Wilkinson

Publications and source records attributed to Eric R Wilkinson.

3 recordsLinked to original sources

Elastographic measurements of in-vivo radiofrequency ablation lesions of the kidney.

BACKGROUND AND PURPOSE: Elastography may prove useful for monitoring radiofrequency ablative (RFA) therapy because heat-ablated tissues are more elastic than untreated tissues. Herein, we report our initial evaluations of the reliability of elastography for delineating thermal-lesion boundaries at the time of RFA of porcine kidneys. MATERIALS AND METHODS: In-vivo RFA was performed on 20 kidneys from 10 40-kg female pigs. Elastography was performed at the time of surgery and after 48 hours. The imaging plane was perpendicular to the axis of the RF electrode so that the ablated region was around the center of the plane. Measurements of the sections representing the same image plane used for elastography were taken at pathologic examination and compared with the measurements obtained from the elastograms. RESULTS: We found a statistically significant correlation between elastography and pathology measurements with respect to the area and volume estimates (r = 0.9302 and r = 0.953, respectively). Overall, elastography slightly underestimated the lesion size, as judged by the digitalized pathologic images, a finding consistent with previous reports. CONCLUSION: We found a correlation between the area and volume estimates of thermal lesions that were based on elastographic images and the measurements from gross pathologic dimensions. A significant limitation of renal RFA is the inaccuracy of current imaging modalities to provide real-time monitoring, and elastography may prove to be reliable for delineating the resulting thermal lesions.

Animals↗

Third prize: Prostaglandin E(2)-3 receptor is involved in ureteral contractility in obstruction.

BACKGROUND AND PURPOSE: We previously found that prostaglandin (PG) E2 contracts acutely obstructed ureters while relaxing normal ureters. This study investigated the procontractile effects of the PG EP3 receptor in PGE(2)-mediated contractility in obstructed and normal porcine ureters. MATERIALS AND METHODS: We created unilateral ureteral obstruction laparoscopically using titanium clips in farm pigs; the contralateral ureters were dissected as sham controls. Ureters were harvested 48 hours post-obstruction, cut into 5-mm segments, and suspended in water-jacketed tissue baths in Krebs buffer. Tissues were equilibrated for 1 hour, and spontaneous contractile rates were recorded. After 2 hours of incubation in Krebs (controls) or pertussis toxin (G(alpha)i signaling-protein inhibitor [EP-3 blockade]) 500 ng/mL, a concentration- response curve (10(-9) M-10(-5) M) to PGE(2), PGF(2), sulprostone (EP 3 agonist), or 0.01% ethanol (vehicle) was created (N = 4). RESULTS: In the normal ureters, PGE(2) relaxed both pertussis toxin-treated and control tissues. In obstructed segments, PGE(2) increased contractions by 60%; this was reversed by pertussis toxin to a 67% reduction in contractile rate. In both obstructed and contralateral segments, sulprostone induced contractility in the controls; this was attenuated by pertussis toxin. The PGF(2) produced a contractile effect in both the controls and the pertussis toxin-treated segments, demonstrating the selectivity of pertussis toxin for EP3 receptors. CONCLUSION: Our data indicate that the EP3 receptor is involved in hypercontractility during ureteral obstruction. However, it may not be the sole factor behind the condition-dependent effect of PGE(2).

Animals↗

Haemostatic partial nephrectomy using bipolar radiofrequency ablation.

OBJECTIVE: To determine whether an electrode array with a bipolar radiofrequency ablation (RFA) energy source can be used to perform a haemostatic partial nephrectomy by simultaneously ablating and coagulating renal tissue. MATERIALS AND METHODS: Lower-pole partial nephrectomy was performed in 12 porcine kidneys using a bipolar RFA system. Intraoperative ultrasonography was used to identify and avoid the collecting system. Tissues were positioned between opposing electrodes and tissue impedance monitored using a proprietary feedback and control algorithm. Ablation time and power, lesion width and length, and tissue thickness were recorded. The kidneys were assessed in vivo to show haemostasis of the remaining renal unit. Collecting system integrity was assessed with methylene blue injection, and the resected tissue analysed histologically. RESULTS: Partial nephrectomies were successful in all 12 porcine kidneys; the mean nephrectomy specimen was 3.2 x 2.6 cm. The total ablation time (sem) per lesion was 211 (15) s and the mean power was 23 W. Methylene blue injection showed an intact collecting system in 11 of the 12 kidneys, and haematoxylin and eosin staining showed a mean zone of necrosis of 9 mm at the resection margin. Ultrasonography revealed flow to the remaining kidneys after RFA and the in vivo assessment of haemostasis revealed no abnormal bleeding or haemorrhage from the kidneys. CONCLUSIONS: Applying bipolar RF energy to an electrode array can enable transmural excision of renal parenchyma in vivo in a bloodless fashion without collecting system injury.

Animals↗