PubMed Health⌕ Search

Biomedical subjects

Eric T Han

Publications and source records attributed to Eric T Han.

7 recordsLinked to original sources

A feasibility study of in vivo T1rho imaging of the intervertebral disc.

PURPOSE: Recent studies have proposed that magnetic resonance (MR) T1rho relaxation time is associated with loss of macromolecules. The depletion of macromolecules in the matrix of the intervertebral disc may be an initiating factor in degenerative disc disease. The purpose of this study was to test the feasibility of quantifying T1rho relaxation time in phantoms and intervertebral discs of healthy volunteers using in vivo MR imaging at 3 T. MATERIALS AND METHODS: A multislice T1rho spiral sequence was used to quantify T1rho relaxation time in phantoms with different agarose concentrations and in the intervertebral discs of 11 healthy volunteers (mean age=31.3 years; age range=23-60 years; gender: 5 females, 6 males). RESULTS: The phantom studies demonstrated the feasibility of using spiral imaging at 3 T. The in vivo results indicate that the median T1rho value of the nucleus (116.6+/-21.4 ms) is significantly greater (P<0.05) than that of the annulus (84.1+/-11.7 ms). The correlations between the age of the volunteers and T1rho relaxation time in the nucleus (r2=-0.82; P=0.0001) and the annulus (r2=-0.37; P=0.04) were significant. A trend of decreasing T1rho values from L3-4 to L4-5 to L5-S1 was evident. CONCLUSION: The results of this study suggest that in vivo T1rho quantification is feasible and may potentially be a clinical tool in identifying early degenerative changes in the intervertebral disc.

Adult↗

Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction.

PURPOSE: To investigate changes in image and dynamic signal-to-noise ratios (SNRs) of the DeltaR2* curve, as well as magnetic susceptibility-induced artifacts between a standard quadrature head coil and an eight-channel phased-array coil with and without sensitivity-encoding (SENSE) at 3T, compared to the current clinical standard head coil acquisition at 1.5T. MATERIALS AND METHODS: Dynamic susceptibility contrast (DSC) perfusion MRI was performed on 80 brain tumor patients using a gradient-echo, echo-planar imaging (EPI) sequence. Image and dynamic SNR were compared between 1.5T and 3T field strengths, a quadrature and eight-channel phased-array coil, and a conventional vs. partially parallel EPI acquisition with SENSE reconstruction. The amount of geometric distortion and signal dropout was quantified and compared between conventional and SENSE EPI acquisitions within the same exam at 3T. RESULTS: An initial 2.6-fold elevation in dynamic SNR was observed in normal-appearing white matter when doubling the field strength (P < 0.001), with an additional 1.7-fold increase found when employing an eight-channel phased-array coil (P < 0.002). Compared to the standard 3T eight-channel coil acquisition, the implementation of SENSE reduced the number of voxels experiencing large anterior shifts in the phase-encode direction, lowered the volume of signal dropout by 2.0-11.5%, and allowed a 1.4-fold increase in slice coverage, while only decreasing the dynamic SNR by 22%. CONCLUSION: SENSE EPI at 3T yielded a significant improvement in dynamic SNR over the 1.5T acquisitions. A significant reduction in magnetic susceptibility-induced artifacts was achieved with SENSE EPI compared to the standard EPI eight-channel coil acquisition at 3T.

Adult↗

Q-ball reconstruction of multimodal fiber orientations using the spherical harmonic basis.

Diffusion tensor imaging (DTI) accurately delineates white matter pathways when the Gaussian model of diffusion is valid. However, DTI yields erroneous results when diffusion takes on a more complex distribution, as is the case in the brain when fiber tracts cross. High angular resolution diffusion imaging (HARDI) overcomes this limitation of DTI by more fully characterizing the angular dependence of intravoxel diffusion. Among the various HARDI methods that have been proposed, QBI offers advantages such as linearity, model independence, and relatively easy implementation. In this work, reconstruction of the q-ball orientation distribution function (ODF) is reformulated in terms of spherical harmonic basis functions, yielding an analytic solution with useful properties of a frequency domain representation. The harmonic basis is parsimonious for typical b-values, which enables the ODF to be synthesized from a relatively small number of noisy measurements and thus brings the technique closer to clinical feasibility from the standpoint of total imaging time. The proposed method is assessed using Monte Carlo computer simulations and compared with conventional q-ball reconstruction using spherical RBFs. In vivo results from 3T whole-brain HARDI of adult volunteers are also provided to verify the underlying mathematical theory.

Adult↗

Measurement of in vivo multi-component T2 relaxation times for brain tissue using multi-slice T2 prep at 1.5 and 3 T.

The objective of this study was to implement a clinically relevant multi-slice multi-echo imaging sequence in order to quantify multi-component T2 relaxation times for normal volunteers at both 1.5 and 3 T. Multi-echo data were fitted using a nonnegative least square algorithm. Twelve echo data with nonlinear echo sampling were acquired using a receive-only eight-channel phased array coil and volume head coil for phantoms and normal volunteers, and compared to 32-echo data with linear echo sampling. It was observed that the performance of the 180 degrees refocusing trains was more spatially uniform for the receive-only eight-channel phased array coil than for the head coil, particularly at 3 T. The phantom study showed that the estimated T2 relaxation times were accurate and reproducible for both single- and multi-slice acquisition from a commercial phantom with known T2 relaxation times. Short T2 components (T2 <50 ms) were mainly observed within the white matter for normal volunteers, and the fraction of short T2 water components (i.e., myelin water) was 7-12% of total water. It was observed that the calculated myelin water fraction map from the nonlinearly sampled 12-echo data was comparable with that from the linearly sampled 32-echo data. Quantification of T2 relaxation times from multi-slice images was accomplished with a clinically acceptable scan times (16 min) for normal volunteers by using a nonselective T2 prep imaging sequence. The use of the eight-channel head coil involved more accurate quantification of T2 relaxation times particularly when the number of echoes was limited.

Adult↗

Quantitative apparent diffusion coefficients and T2 relaxation times in characterizing contrast enhancing brain tumors and regions of peritumoral edema.

PURPOSE: To investigate the potential value and relationship of in vivo quantification of apparent diffusion coefficients (ADCs) and T2 relaxation times for characterizing brain tumor cellularity and tumor-related edema. MATERIALS AND METHODS: A total of 26 patients with newly diagnosed gliomas, meningiomas, or metastases underwent diffusion-weighted and six-echo multisection T2-preparation imaging. Regions of interest (ROIs) were drawn on conventional MR images to include tumor (as defined by contrast agent enhancement) and immediate and peripheral edema. Areas of necrosis were excluded. Median values of ADCs and T2 in the ROIs were calculated. RESULTS: ADCs for gliomas were similar to those for meningiomas or metastases in all regions. Tumor T2 values for gliomas (159.5+/-30.6 msec) were significantly higher than those for meningiomas or metastases (125.0+/-31.1 msec; P=0.005). Immediate-edema T2 values for meningiomas or metastases (226.0+/-44.1 msec) were significantly higher than those for gliomas (203.5+/-32.8 msec; P=0.033). Peripheral-edema T2 values for gliomas (219.5+/-41.9 msec) were similar to those for meningiomas or metastases (202.5+/-26.5 msec; P=0.377). Both immediate- and peritumoral-edema ADCs and T2 values were significantly higher than those in tumor for both tumor types. ADCs and T2 values from all regions correlated significantly for gliomas (r=0.95; P<0.0001) and for meningiomas or metastases (r=0.81; P<0.0001). CONCLUSION: The higher immediate-edema T2 values for nonglial tumors than for gliomas suggest tumor-related edema (vasogenic vs. infiltrated) can be further characterized by using T2 values. There were significant correlations between ADC and T2 values.

Adult↗

Application of refocused steady-state free-precession methods at 1.5 and 3 T to in vivo high-resolution MRI of trabecular bone: simulations and experiments.

PURPOSE: To evaluate the potential of fully-balanced steady-state free-precession (SSFP) sequences in in vivo high-resolution (HR) MRI of trabecular bone at field strengths of 1.5 and 3 T by simulation and experimental methods. MATERIALS AND METHODS: Using simulation studies, refocused SSFP acquisition was optimized for our imaging purposes with a focus on signal-to-noise ratio (SNR) and SNR efficiency. The signal behavior in trabecular bone was estimated using a magnetostatic model of the trabecular bone and marrow. Eight normal volunteers were imaged at the proximal femur, calcaneus, and the distal tibia on a GE Signa scanner at 1.5 and at 3 T with an optimized single-acquisition SSFP sequence (three-dimensional FIESTA) and an optimized multiple-acquisition SSFP sequence (three-dimensional FIESTA-c). Images were also acquired with a fast gradient echo (FGRE) sequence for evaluation of the SNR performance of SSFP methods. RESULTS: Refocused SSFP images outperformed FGRE acquisitions in both SNR and SNR efficiency at both field strengths. At 3 T, susceptibility effects were visible in FIESTA and FGRE images and much reduced in FIESTA-c images. The magnitude of SNR boost at 3 T was closely predicted by simulations. CONCLUSION: Single-acquisition SSFP (at 1.5 T) and multiple-acquisition SSFP (at 3 T) hold great potential for HR-MRI of trabecular bone.

Adult↗

In vivo 3T spiral imaging based multi-slice T(1rho) mapping of knee cartilage in osteoarthritis.

T(1rho) describes the spin-lattice relaxation in the rotating frame and has been proposed for detecting damage to the cartilage collagen-proteoglycan matrix in osteoarthritis. In this study, a multi-slice T(1rho) imaging method for knee cartilage was developed using spin-lock techniques and a spiral imaging sequence. The adverse effect of T(1) regrowth during the multi-slice acquisition was eliminated by RF cycling. Agarose phantoms with different concentrations, 10 healthy volunteers, and 9 osteoarthritis patients were scanned at 3T. T(1rho) values decreased as agarose concentration increased. T(1rho) values obtained with imaging methods were compared with those obtained with spectroscopic methods. T(1rho) values obtained during multi-slice acquisition were validated with those obtained in a single slice acquisition. Reproducibility was assessed using the average coefficient of variation of median T(1rho), which was 0.68% in phantoms and 4.8% in healthy volunteers. There was a significant difference (P = 0.002) in the average T(1rho) within patellar and femoral cartilage between controls (45.04 +/- 2.59 ms) and osteoarthritis patients (53.06 +/- 4.60 ms). A significant correlation was found between T(1rho) and T(2); however, the difference of T(2) was not significant between controls and osteoarthritis patients. The results suggest that T(1rho) relaxation times may be a promising clinical tool for osteoarthritis detection and treatment monitoring.

Adolescent↗