PubMed Health⌕ Search

Biomedical subjects

Eric Verbeken

Publications and source records attributed to Eric Verbeken.

22 records · Page 2Linked to original sources

Long-term biocompatibility evaluation of a novel polymer-coated stent in a porcine coronary stent model.

BACKGROUND: Polymer coatings have been used to modify the surface of stents and to serve as a matrix for local drug delivery. METHODS: Bare stainless steel stents or poly-bis-trifluorethoxy phosphazene (PTFEP) dip-coated stents (Coroflex, Germany) were randomly implanted into porcine coronary arteries with a balloon-to-artery ratio of 1.1-1.2 : 1. Scanning electron microscopy (SEM), repeat quantitative coronary angiography (QCA) and histomorphometric analysis were performed at 5 days, 6 weeks and 6 months. RESULTS: At 5 days, complete endothelial cell coverage with fibrin strands was detected in both the bare and the coated stents with SEM. Late loss, determined by QCA, of coated and bare stents was identical at all time points. Histomorphometric analysis showed that coated and bare stents elicited a similar tissue response at 5 days. At 6 weeks, the coated stents showed a moderate peri-strut inflammatory response, resulting in increased neointimal hyperplasia. Compared to the bare stents, however, no significant differences were observed. At 6 months, peri-strut inflammation was minimal and similar in the coated and the bare stent groups. Neointimal hyperplasia of the coated and bare stent groups was also comparable (1.37+/-0.44 compared with 1.15+/-0.40 mm2, P=0.213) and decreased compared to the 6-week response. CONCLUSION: This PTFEP stent coating showed a long-term biocompatibility in a porcine coronary stent model. Because no increased proliferative response was observed up to 6 months, this phosphazene coating may serve as a vehicle for local drug delivery.

Animals↗

Ischemic preconditioning reduces unloaded myocardial oxygen consumption in an in-vivo sheep model.

OBJECTIVE: Ischemic preconditioning (IP) describes the adaptation of the myocardium to ischemic stress preceded by short periods of ischemia and reperfusion. However, its cardioprotective mechanisms are not completely understood. We assessed the effect of IP on ventricular energetics in an in-vivo sheep model. METHODS: IP was performed in six sheep by three 5 min aortic cross-clamping periods interspersed with 5 min of reperfusion during cardiopulmonary bypass and with six sheep as time-matched controls. Global myocardial ischemia was subsequently achieved by 30 min aortic cross-clamping with left ventricular unloading during normothermic cardiopulmonary bypass. Weaning from cardiopulmonary bypass was performed 40 min after reperfusion. At baseline, after treatment (IP or time-matched cardiopulmonary bypass), and up to 100 min after reperfusion, left ventricular pressure-volume loops were measured using a conductance catheter during a right heart bypass preparation. Contractility, diastolic function, and ventriculo-arterial coupling were evaluated. Ventricular energetics [the relation between myocardial oxygen consumption (MVO(2)) and systolic pressure-volume area (PVA)] was also evaluated. A right heart bypass was instituted to control the preload and to decompress the right ventricle completely, thereby eliminating parallel conductance variation and minimizing the contribution of the right ventricle to MVO(2). RESULTS: IP reduced unloaded MVO(2) (PVA-independent MVO(2)). Contractility, diastolic function, and ventriculo-arterial coupling in the IP group were better preserved than in the control group after ischemia-reperfusion. CONCLUSIONS: IP reduces unloaded MVO(2), and preserves contractility, diastolic function, and ventriculo-arterial coupling after 30 min global myocardial ischemia in an in-vivo sheep model.

Analysis of Variance↗

Melphalan availability in hypoxia-inducible factor-1alpha+/+ and factor-1alpha-/- tumors is independent of tumor vessel density and correlates with melphalan erythrocyte transport.

Many tumors are impervious to anticancer agents. Resistance due to lack of cytotoxic penetration into the tumor is often overlooked but can play a significant role in undermining therapy. Insufficient and irregular vascularization of tumors is a possible barrier to drug delivery, but there are others, e.g., impaired vessel permeability and poor interstitial transport. We evaluated the importance of tumor vessel density in the availability of melphalan to tumors. A nude mouse tumor model with different vascularization due to a single-gene deletion of hypoxia-inducible factor 1alpha (HIF-1alpha(+/+) and HIF-1alpha(-/-) embryonic stem cell-derived tumors) was used. The availability of melphalan to HIF-1alpha(+/+) (n = 20) and HIF-1alpha(-/-) (n = 23) tumors was not significantly different (p = 0.12). Furthermore, in the various subgroup analyses accentuating the difference in vessel density, no significant correlation between vessel density and melphalan availability was found. In the second part of the study, melphalan, was demonstrated to be transported in blood in mice with a distribution of 24% in erythrocytes vs. 76% in plasma. A strong correlation (r = 0.93, p < 0.000001) between melphalan concentrations in plasma and erythrocytes was found, indicating an equilibrium between these 2 compartments. Plasma and erythrocyte concentrations of melphalan are correlated with the tumor availability of melphalan (r = 0.66 and 0.64, respectively, both p < 0.001). These data suggest that tumor vessel density is not an important predictor of the tumor availability of small cytotoxic drugs such as melphalan and indicate the importance of erythrocytes in the transport of melphalan.

Animals↗

In-vivo biocompatibility evaluation of stents coated with a new biodegradable elastomeric and functional polymer.

BACKGROUND: In-stent restenosis may be prevented by impregnating an antiproliferative agent in a polymer from a stent platform. This approach requires both an antiproliferative agent effective in small doses and a biocompatible polymer. METHODS: A series of new biodegradable elastomeric poly(ester-amide)(co-PEA) polymers having functional carboxyl groups for drug conjugation were synthesized from non-toxic building blocks. The in-vivo biocompatibility was tested in porcine coronary arteries, by comparing the polymer-coated stents with bare metal stents in 10 pigs. RESULTS: All animals survived until sacrifice 28 days later and follow-up angiography prior to sacrifice revealed identical diameter stenosis (21 +/- 23%) in both groups. Histology confirmed similar injury scores (0.34 +/- 0.34 compared with 0.34 +/- 0.32), inflammatory reaction (1.18 +/- 0.38 compared with 1.11 +/- 0.32) and area stenosis (26 +/- 17% compared with 28 +/- 22%). CONCLUSIONS: This study suggests that the newly developed copoly(ester-amide) elastomers may be suitable for stent-based local drug delivery.

Absorbable Implants↗