PubMed Health⌕ Search

Biomedical subjects

Eric Vigneault

Publications and source records attributed to Eric Vigneault.

13 recordsLinked to original sources

Permanent prostate implant using high activity seeds and inverse planning with fast simulated annealing algorithm: A 12-year Canadian experience.

PURPOSE: To report outcomes and toxicity of the first Canadian permanent prostate implant program. METHODS AND MATERIALS: 396 consecutive patients (Gleason < or =6, initial prostate specific antigen (PSA) < or =10 and stage T1-T2a disease) were implanted between June 1994 and December 2001. The median follow-up is of 60 months (maximum, 136 months). All patients were planned with fast-simulated annealing inverse planning algorithm with high activity seeds ([gt] 0.76 U). Acute and late toxicity is reported for the first 213 patients using a modified RTOG toxicity scale. The Kaplan-Meier biochemical failure-free survival (bFFS) is reported according to the ASTRO and Houston definitions. RESULTS: The bFFS at 60 months was of 88.5% (90.5%) according to the ASTRO (Houston) definition and, of 91.4% (94.6%) in the low risk group (initial PSA < or =10 and Gleason < or =6 and Stage < or =T2a). Risk factors statistically associated with bFFS were: initial PSA >10, a Gleason score of 7-8, and stage T2b-T3. The mean D90 was of 151 +/- 36.1 Gy. The mean V100 was of 85.4 +/- 8.5% with a mean V150 of 60.1 +/- 12.3%. Overall, the implants were well tolerated. In the first 6 months, 31.5% of the patients were free of genitourinary symptoms (GUs), 12.7% had Grade 3 GUs; 91.6% were free of gastrointestinal symptoms (GIs). After 6 months, 54.0% were GUs free, 1.4% had Grade 3 GUs; 95.8% were GIs free. CONCLUSION: The inverse planning with fast simulated annealing and high activity seeds gives a 5-year bFFS, which is comparable with the best published series with a low toxicity profile.

Aged↗

Bypassing the learning curve in permanent seed implants using state-of-the-art technology.

PURPOSE: The aim of this study was to demonstrate, based on clinical postplan dose distributions, that technology can be used efficiently to eliminate the learning curve associated with permanent seed implant planning and delivery. METHODS AND MATERIALS: Dose distributions evaluated 30 days after the implant of the initial 22 consecutive patients treated with permanent seed implants at two institutions were studied. Institution 1 (I1) consisted of a new team, whereas institution 2 (I2) had performed more than 740 preplanned implantations over a 9-year period before the study. Both teams had adopted similar integrated systems based on three-dimensional (3D) transrectal ultrasonography, intraoperative dosimetry, and an automated seed delivery and needle retraction system (FIRST, Nucletron). Procedure time and dose volume histogram parameters such as D90, V100, V150, V200, and others were collected in the operating room and at 30 days postplan. RESULTS: The average target coverage from the intraoperative plan (V100) was 99.4% for I1 and 99.9% for I2. D90, V150, and V200 were 191.4 Gy (196.3 Gy), 75.3% (73.0%), and 37.5% (34.1%) for I1 (I2) respectively. None of these parameters shows a significant difference between institutions. The postplan D90 was 151.2 Gy for I1 and 167.3 Gy for I2, well above the 140 Gy from the Stock et al. analysis, taking into account differences at planning, results in a p value of 0.0676. The procedure time required on average 174.4 min for I1 and 89 min for I2. The time was found to decrease with the increasing number of patients. CONCLUSION: State-of-the-art technology enables a new brachytherapy team to obtain excellent postplan dose distributions, similar to those achieved by an experienced team with proven long-term clinical results. The cost for bypassing the usual dosimetry learning curve is time, with increasing team experience resulting in shorter treatment times.

Brachytherapy↗

Prostatic edema in 125I permanent prostate implants: dynamical dosimetry taking volume changes into account.

The purpose of this study is to determine the impact of edema on the dose delivered to the target volume. An evaluation of the edema characteristics was first made, and then a dynamical dosimetry algorithm was developed and used to compare its results to a standard clinical (static) dosimetry. Source positions and prostate contours extracted from 66 clinical cases on images taken at different points in time (planning, implant day, post-implant evaluation) were used, via the mean interseed distance, to characterize edema [initial increase (deltar0), half-life (tau)]. An algorithm was developed to take into account the edema by summing a time series of dose-volume histograms (DVHs) with a weight based on the fraction of the dose delivered during the time interval considered. The algorithm was then used to evaluate the impact of edema on the dosimetry of permanent implants by comparing its results to those of a standard clinical dosimetry. The volumetric study yielded results as follows: the initial prostate volume increase was found to be 1.58 (ranging from 1.15 to 2.48) and the edema half-life, approximately 30 days (range: 3 to 170 days). The dosimetric differences in D90 observed between the dynamic dosimetry and the clinical one for a single case were up to 15 Gy and depended on the edema half-life and the initial volume increase. The average edema half-life, 30 days, is about 3 times longer than the previously reported 9 days. Dosimetric differences up to 10% of the prescription dose are observed, which can lead to differences in the quality assertion of an implant. The study of individual patient edema resorption with time might be necessary to extract meaningful clinical correlation or biological parameters in permanent implants.

Algorithms↗

Randomized trial of antioxidant vitamins to prevent acute adverse effects of radiation therapy in head and neck cancer patients.

PURPOSE: Many cancer patients take antioxidant vitamin supplements with the hope of improving the outcome of conventional therapies and of reducing the adverse effects of these treatments. A randomized trial was conducted to determine whether supplementation with antioxidant vitamins could reduce the occurrence and severity of acute adverse effects of radiation therapy and improve quality of life without compromising treatment efficacy. PATIENTS AND METHODS: We conducted a randomized, double-blind, placebo-controlled trial among 540 head and neck cancer patients treated with radiation therapy. Patients were randomly assigned into two arms. The supplementation with alpha-tocopherol (400 IU/d) and beta-carotene (30 mg/d) or placebos was administered during radiation therapy and for 3 years thereafter. During the course of the trial, supplementation with beta-carotene was discontinued because of ethical concerns. RESULTS: Patients randomly assigned in the supplement arm tended to have less severe acute adverse effects during radiation therapy (odds ratio [OR], 0.72; 95% CI, 0.52 to 1.02). The reduction was statistically significant when the supplementation combined alpha-tocopherol and beta-carotene for adverse effects to the larynx (OR, 0.38; 95% CI, 0.21 to 0.71) and overall at any site (OR, 0.38; 95% CI, 0.20 to 0.74). Quality of life was not improved by the supplementation. The rate of local recurrence of the head and neck tumor tended to be higher in the supplement arm of the trial (hazard ratio, 1.37; 95% CI, 0.93 to 2.02). CONCLUSION: Supplementation with high doses of alpha-tocopherol and beta-carotene during radiation therapy could reduce the severity of treatment adverse effects. However, this trial suggests that use of high doses of antioxidants as adjuvant therapy might compromise radiation treatment efficacy.

Acute Disease↗

A randomized trial of antioxidant vitamins to prevent second primary cancers in head and neck cancer patients.

BACKGROUND: Although low dietary intakes of antioxidant vitamins and minerals have been associated with higher risks of cancer, results of trials testing antioxidant supplementation for cancer chemoprevention have been equivocal. We assessed whether supplementation with antioxidant vitamins could reduce the incidence of second primary cancers among patients with head and neck cancer. METHODS: We conducted a multicenter, double-blind, placebo-controlled, randomized chemoprevention trial among 540 patients with stage I or II head and neck cancer treated by radiation therapy between October 1, 1994, and June 6, 2000. Supplementation with alpha-tocopherol (400 IU/day) and beta-carotene (30 mg/day) or placebo began on the first day of radiation therapy and continued for 3 years after the end of radiation therapy. In the course of the trial, beta-carotene supplementation was discontinued after 156 patients had enrolled because of ethical concerns. The remaining patients received alpha-tocopherol or placebo only. Survival was evaluated by Kaplan-Meier analysis. Cox proportional hazards models were used to estimate hazard ratios (HRs) and 95% confidence intervals (CIs). All statistical tests were two-sided. RESULTS: After a median follow-up of 52 months, second primary cancers and recurrences of the first tumor were diagnosed in 113 and 119 participants, respectively. The effect of supplementation on the incidence of second primary cancers varied over time. Compared with patients receiving placebo, patients receiving alpha-tocopherol supplements had a higher rate of second primary cancers during the supplementation period (HR = 2.88, 95% CI = 1.56 to 5.31) but a lower rate after supplementation was discontinued (HR = 0.41, 95% CI = 0.16 to 1.03). Similarly, the rate of having a recurrence or second primary cancer was higher during (HR = 1.86, 95% CI = 1.27 to 2.72) but lower after (HR = 0.71, 95% CI = 0.33 to 1.53) supplementation with alpha-tocopherol. The proportion of participants free of second primary cancer overall after 8 years of follow-up was similar in both arms. CONCLUSIONS: alpha-Tocopherol supplementation produced unexpected adverse effects on the occurrence of second primary cancers and on cancer-free survival.

Adult↗

Psychological functioning associated with prostate cancer: cross-sectional comparison of patients treated with radiotherapy, brachytherapy, or surgery.

This study compared the prevalence of psychological difficulties (i.e., anxiety and depression), psychophysiological problems (i.e., insomnia and fatigue), and sexual difficulties across three modalities of treatment for prostate cancer (radiotherapy, brachytherapy, and radical prostatectomy). A total of 861 men completed a battery of questionnaires assessing anxiety, depression, fatigue, insomnia, and quality of life. Patients who initially received radiotherapy had higher levels of depression, anxiety, and fatigue and a lower quality of life, and were more likely to report clinical levels of depression and fatigue. Patients who initially received surgery were more likely to report clinical levels of sexual difficulties but less likely to report clinical levels of depression and fatigue, while patients who received brachytherapy were less likely to report sexual difficulties. Although cross-sectional, these findings raise the possibility of a differential influence of treatments for prostate cancer on some aspects of psychological functioning.

Aged↗

Anatomy-based inverse planning dose optimization in HDR prostate implant: a toxicity study.

BACKGROUND AND PURPOSE: The aim of this study is to evaluate the acute and late complications in patients who have received HDR implant boost using inverse planning, and to determine dose volume correlations. PATIENTS AND METHODS: Between September 1999 and October 2002, 44 patients with locally advanced prostate cancer (PSA>/=10 ng/ml, and/or Gleason score>/=7, and/or Stage T2c or higher) were treated with 40-45 Gy external pelvic field followed by 2--3 fraction of inverse-planned HDR implant boost (6--9.5 Gy /fraction). Median follow-up time was 1.7 years with 81.8% of patients who had at least 12 months of follow up (range 8.6--42.5. Acute and late morbidity data were collected and graded according to RTOG criteria. Questionnaires were used to collect prostate related measures of quality of life, and international prostate symptom score (IPSS) before and after treatment. Dose-volume histograms for prostate, urethra, bladder, penis bulb and rectum were analyzed. RESULTS: The median patient age was 64 years. Of these, 32% were in the high risk group, and 61% in the intermediate risk group. 3 patients (7%) had no adverse prognostic factors. A single grade 3 GU acute toxicity was reported but no grade 3--4 acute GI toxicity. No grade 3--4 late GU or GI toxicity was reported. Acute (late) grade 2 urinary and rectal symptoms were reported in 31.8 (11.4%) and 4.6% (4.6%) of patients, respectively. A trend for predicting acute GU toxicity is seen for total HDR dose of more than 18 Gy (OR=3.6, 95%CI=[0.96--13.5], P=0.058). The evolution of toxicity is presented for acute and late GU/GI toxicity. Erectile dysfunction occurs in approximately 27% of patients who were not on hormonal deprivation, but may be taking sildenafil. The IPSS peaked on averaged 6 weeks post-implant and returned to the baseline at a median of 6 months. CONCLUSIONS: Inverse-planned HDR brachytherapy is a viable option to deliver higher dose to the prostate as a boost without increasing GU or rectal complication. Further HDR dose escalation to the prostate is feasible.

Adenocarcinoma↗

Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers.

PURPOSE: To measure the interfraction and intrafraction motion of the prostate during the course of external beam radiotherapy using a video electronic portal imaging device and three-dimensional analysis. METHODS AND MATERIALS: Eighteen patients underwent implantation with two or three gold markers in the prostate before five-angle/11-field conformal radiotherapy. Using CT data as the positional reference, multiple daily sets of portal images, and a three-dimensional reconstruction algorithm, intrafraction translations, as well as interfraction and intrafraction rotations, were analyzed along the three principal axes (left-right [LR], superoinferior [SI], and AP). The overall mean values and standard deviations (SDs), along with random and systematic SDs, were computed for these translations and rotations. RESULTS: For 282 intrafraction translational displacements, the random SD was 0.8 mm (systematic SD, 0.2) in the LR, 1.0 mm (systematic SD, 0.4) in the SI, and 1.4 mm (systematic SD, 0.7) in the AP axes. The analysis of 348 interfraction rotations revealed random SDs of 6.1 degrees (systematic SD, 5.6 degrees ) around the LR axis, 2.8 degrees (systematic SD, 2.4 degrees ) around the SI axis, and 2.0 degrees (systematic SD, 2.2 degrees ) around the AP axis. The intrafraction rotational motion observed during 44 fractions had a random SD of 1.8 degrees (systematic SD, 1.0 degrees ) around the LR, 1.1 degrees (systematic SD, 0.8 degrees ) around the SI, and 0.6 degrees (systematic SD, 0.3 degrees ) around the AP axis. CONCLUSION: The interfraction rotations observed were more important than those reported in previous studies. Intrafraction motion was generally smaller in magnitude than interfraction motion. However, the intrafraction rotations and translations of the prostate should be taken into account when designing planning target volume margins because their magnitudes are not negligible.

Humans↗

Idealized line source configuration for permanent 125I prostate implants.

BACKGROUND AND PURPOSE: To validate the use of idealized seed orientations in conjunction with the line source formalism for post-implant dosimetry of permanent 125I prostate implants. PATIENTS AND METHODS: Post-implant, a CT scan and three fluoroscopic images were obtained for 32 patients having undergone permanent implants. From these images, the seed positions and orientations (phi,theta) were determined (1625 individual seeds). Two different dosimetric calculations were done: one using real orientations and one using idealized orientations (seeds along the axis of implantation). Dose volume histograms (DVHs) and key dosimetric parameters were compiled for the prostate, urethra, rectum, bladder and penile bulb, to evaluate the difference between the two approximations. RESULTS: The phi angle distribution (phi = 1.1 degrees; sigma phi = 22.9 degrees) and the theta angle distribution (theta= -4.29 degrees; sigma theta = 27.1 degrees) were found to be similar to the first order except for the pronounced peak of the phi angle distribution. The DVHs comparison and dosimetric parameters study reveal no significant difference between the two approximations. The difference in D90 for the prostate was only 0.02% (sigma = 0.91%) The differences were slightly higher in the case of the organs at risk, as expected from the dosimetric characteristics of the seed model used. CONCLUSIONS: The angular distributions (phi,theta) of individual seeds were determined. The dosimetric evaluation shows that line source formalism can be used in conjunction with an idealized seed configuration presented here to report prostate and organs at risk dose coverage.

Brachytherapy↗

Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate.

PURPOSE: To present an exhaustive dosimetric comparison between three geometric optimization methods and our inverse-planning simulated annealing (IPSA) algorithm, with two different prescriptions for high-dose-rate (HDR) boost of the prostate. The objective of this analysis was to quantify the dosimetric advantages of the IPSA algorithm compared with more standard geometric optimizations. METHODS AND MATERIALS: Between September 1999 and June 2001, 34 patients were treated to a dose of 40-44 Gy by external pelvic fields, followed by an HDR boost of 18 Gy in 3 fractions. The first 4 patients were treated with HDR using geometric optimization, and anatomy-based inverse-planning dose optimization was used for the remaining 30 patients. We retrospectively used the data from these 30 patients to create HDR dose distributions according to five different dose optimization protocols, including our IPSA algorithm. The various geometric optimization procedures differed in the way the dwell positions were activated and plan normalization was performed. Dose-volume histograms from all these plans were analyzed and multiple implant quality indexes extracted. RESULTS: The IPSA algorithm provided better clinical tumor volume prescription dose coverage than did the geometric optimizations. The average prostate volume receiving 100% of the prescribed dose (V100) was 96.3% and 94.5% for IPSA with two different prescriptions compared with 92.1%, 92.6%, and 88.8% for the three geometric optimization schemes. The average urethra V150 value was 0.0% and 0.7% for IPSA with two different prescriptions, and the three geometric optimization protocols generated average values of 22.9%, 33.9%, and 38.8%. The bladder and rectal dose-volume histograms were similar, although the latest version of the IPSA algorithm slightly decreases the dose to these organs at risk because of organ-specific dose constraints included in the objective function. CONCLUSION: We found that planning an HDR prostate boost could be performed in a fast, secure, and effective manner with the IPSA algorithm. We demonstrated that our inverse-planning algorithm produces superior HDR plans than more conventional geometric optimizations for adenocarcinoma of the prostate. The organs at risk protection included in the objective function is a major feature of the algorithm and should allow us to escalate the HDR dose to the prostate without increasing undesirable side effects.

Adenocarcinoma↗

Dosimetric impact of the variation of the prostate volume and shape between pretreatment planning and treatment procedure.

PURPOSE: The goal of this study is to evaluate the dosimetric impact on a pretreatment planning of prostatic volume and shape variations occurring between the moment of the volume study (preplanning) and just before a transperineal permanent seed implant procedure. Such variations could be an obvious source of misplacement of the seeds relative to the prostate gland and organs at risk. Other sources of dosimetric uncertainties, such as misplacement due to the procedure itself or edema, are eliminated by looking at these variations before the implant procedure. METHODS AND MATERIALS: For 35 clinical cases, prostate contours were taken at preplanning time as well as in the operating room (OR) minutes before the procedure. Comparison of shape and volume between the two sets was made. The impact on V100 was evaluated by placing the seeds in their planned positions in the new volume (clinical situation) and also by performing a new plan with the second set of contours to simulate an intraoperative approach. RESULTS: The volume taken in the OR remained unchanged compared to the pretreatment planning volume in only 37% of the cases. While on average the dose coverage loss from pretreatment planning due to a combination of variations of volume and shape was small at 5.7%, a V100 degradation of up to 20.9% was observed in extreme cases. Even in cases in which no changes in volume were observed, changes in shape occurred and strongly affected implant dosimetry. CONCLUSIONS: Variations of volume and shape between pretreatment planning and the implant procedure can have a strong impact on the dosimetry if the planning and the implant procedure are not performed on the same day. This is an argument in favor of performing implant dosimetry in the OR.

Brachytherapy↗

A comparison between tandem and ovoids and interstitial gynecologic template brachytherapy dosimetry using a hypothetical computer model.

PURPOSE: To evaluate the dose distribution within the clinical target volume between two gynecologic brachytherapy systems---the tandem and ovoids and the Syed-Neblett gynecologic template---using a hypothetical computer model. METHODS AND MATERIALS: Source positions of an intracavitary system (tandem and ovoids) and an interstitial system (GYN template) were digitized into the Nucletron Brachytherapy Planning System. The GYN template is composed of a 13-catheter implant (12 catheters plus a tandem) based on the Syed-Neblett gynecologic template. For the tandem and ovoids, the dwell times of all sources were evenly weighted to produce a pear-shaped isodose distribution. For the GYN template, the dwell times were determined using volume optimization. The prescribed dose was then normalized to point A in the intracavitary system and to a selected isodose line in the interstitial system. The treated volume in the two systems was kept approximately the same, and a cumulative dose-volume histogram of the treated volume was then generated with the Nucletron Brachytherapy Planning System to use for comparison. To evaluate the dose to a hypothetical target, in this case the cervix, a 2-cm-long, 3-cm-diameter cylinder centered along the tandem was digitized as the clinical target volume. The location of this hypothetical cervix was based on the optimal application of the brachytherapy system. A visual comparison of clinical target coverage by the treated volume on three different orthogonal planes through the treated volume was performed. The percentage dose-volume histograms of the target were generated for comparison. Multiple midline points were also placed at 5-mm intervals away from the tandem in the plane of the cervix to simulate the location of potential bladder and rectal dose points. Doses to these normal structures were calculated for comparison. RESULTS: Although both systems covered the hypothetical cervix adequately, the interstitial system had a better coverage of the region lateral to the cervix. Smaller volumes of the vagina and uterine fundus received the full dose from the interstitial implant. The cumulative dose-volume histograms revealed larger high-dose regions within the treatment volume for the intracavitary system. The volumes receiving > or = 180% of the prescription dose were 31 cc and 17 cc for the intracavitary system and interstitial system, respectively. The isodose lines showed that most of this difference results from the high-dose region around the tandem. The percentage dose-volume histograms showed that a larger percentage of cervix received a higher dose in the intracavitary system. Fifty-two percent of the target volume received 200% or higher of the prescription dose with tandem and ovoids, compared with only 20% with the template system. Analysis of dose points outside of the 100% isodose lines showed a slightly more rapid dose drop-off with the interstitial system compared to the intracavitary system. Point doses at 20, 25, and 30 mm from the tandem in the interstitial system were 100%, 69%, and 51% of prescribed dose, and from the intracavitary system were 101%, 76%, and 58%, respectively. CONCLUSIONS: Our dosimetric analysis revealed a better coverage in the parametrial regions, but underdosage of the central cervical region, for the interstitial system. On the other hand, because of the increased distance of source to dose point, there is a more rapid dose drop-off outside the treated volume with the interstitial system, which has the potential to improve tissue sparing. Based on this analysis, we caution against using a radiotherapy system with a homogeneous central dose distribution when treating cervical cancer with an intact uterus. We recommend differential loading of the implant catheters with the majority of dose delivered from the tandem when using an interstitial GYN template with remote afterloader.

Brachytherapy↗