PubMed Health⌕ Search

Biomedical subjects

Erik A M Beckers

Publications and source records attributed to Erik A M Beckers.

5 recordsLinked to original sources

Recurrent acute hemolytic transfusion reactions by antibodies against Doa antigens, not detected by cross-matching.

An 81-year-old male patient suffered from recurrent acute hemolytic transfusion reactions after transfusion with phenotyped cross-match-negative red blood cells (RBCs). Extensive posttransfusion workup eventually revealed Dombrock (a) (Do(a)) antibodies. Because commercially available cell panels do not allow for identification of anti-Do(a) and owing to the lack of Do(a) typing serum samples, selection of matched units of RBCs is dependent on negative cross-match results. In this case, selection of Do(a-) units by cross-matching failed, indicating that serologic methods were not reliable. A polymerase chain reaction with sequence-specific priming assay was used to detect DOA and DOB alleles, which encode Do(a) and Do(b) antigens, respectively. The patient was confirmed to be DOB/DOB by DNA sequencing. Furthermore, the involved mismatched units in each of the three hemolytic episodes were shown to be Do(a+). In the presenting case, DNA typing appeared to be superior to serologic methods in selecting matched RBC units in the presence of anti-Do(a).

ADP Ribose Transferases↗

Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the Netherlands.

BACKGROUND: Bacterial contamination of blood products is a great hazard for development of fatal transfusion reactions. Bacterial screening of platelet concentrates (PC) by aerobic and anaerobic culturing (BacT/ALERT, bioMérieux) was introduced in the Netherlands in October 2001. STUDY DESIGN AND METHODS: In November 2002, a nationwide, uniform skin cleansing method was introduced with a double-swab disinfection with 70 percent isopropyl alcohol. One location routinely used an integrated diversion bag to collect the first 20 to 30 mL. RESULTS: Over the calendar years 2002 and 2003, in total 113,093 PCs derived from pooled buffy coats were screened. After introduction of the new disinfection method, 0.85 percent were initially positive. This was a small reduction compared to the previous disinfection methods under which 0.95 percent were initially positive. The location with use of the diversion bag showed a significantly lower frequency of bacterial contamination, with 0.50 percent before and 0.37 percent after introduction of 70 percent isopropyl alcohol. In addition 8000 apheresis PCs were also screened, showing 24 initially positive samples (0.30%). CONCLUSION: The use of the diversion bag and, to a lesser extent, the use of double swabs with 70 percent isopropyl alcohol, led to a reduction of contamination. As expected, predominant contamination with resident skin bacteria was reduced. The combination of diversion bag and new disinfection led to a frequency of initial positive results for pooled five-donor PCs, which is similar to that of single-donor apheresis PCs. Furthermore, the bacterial detection system and associated product recall procedures have been shown to be effective in preventing transfusion of contaminated PCs and/or related red cells, especially for rapidly growing bacteria.

2-Propanol↗

Bacterial detection of platelets: current problems and possible resolutions.

The greatest transfusion-transmitted disease risk facing a transfusion recipient is that of bacterial sepsis. The prevalence of bacterial contamination in platelets and red blood cells is approximately 1 in 3,000 units transfused. The available data indicate that transfusion-associated sepsis develops after 1 in 25,000 platelet transfusions and 1 in 250,000 red blood cell transfusions. One of the most widely used strategies for decreasing bacterial sepsis risk is bacterial detection. A roundtable meeting of experts was convened during the XXVIII Annual Congress of the International Society of Blood Transfusion (Edinburgh, UK, July 2004) to provide a forum for experts to share their experiences in the routine bacterial detection of platelet products. This article summarizes the presentations, discussions, and recommendations of the panel. The data presented indicate that some of the current bacterial screening technology is useful for blocking the issuance of platelet units that contain relatively high levels of contaminating bacteria. Platelet units are usually released based on a test-negative status, which often become test-positive only upon longer storage. These data thus suggest that bacterial screening may not prevent all transfusion-transmitted bacterial infections. Two transfusion-transmitted case reports further highlighted the limitation of the routine bacterial screening of platelet products. It was felt that newer technologies, such as pathogen inactivation, may represent a more reliable process, with a higher level of safety. The panel thus recommended that the Transfusion Medicine community may need to change its thinking (paradigm) about bacterial detection, toward the possibility of the pathogen inactivation of blood products, to deal with the bacterial contamination issue. It was suggested, where permitted by regulatory agencies, that blood centers should consider adopting first-generation pathogen inactivation systems as a more effective approach to reducing the risk of transfusion-associated sepsis than some of the approaches currently available.

Bacteria↗

Functional characteristics of photochemically treated platelets.

BACKGROUND: A photochemical treatment (PCT) process using the psoralen compound amotosalen HCL (S59) and long wavelength UVA light was developed for inactivation of infectious pathogens and WBCs. In this study the effect of PCT on functional characteristics of the platelets was evaluated in vitro. STUDY DESIGN AND METHODS: Platelet concentrates were treated photochemically using the experimental clinical processing system T-bag S59 Reduction Device (SRD) (n = 4) or the commercially available integral processing system Wafer SRD (n = 4) and compared with control platelet concentrates in plasma/PAS III alone (n = 4). The evaluation included variables with respect to the overall quality of the product (e.g., HSR, pH), the function (aggregation and activation tests), apoptosis (annexin V and caspase 3), and lysis. RESULTS: No differences were found in the product quality variables, in P-selectin expression, and the apoptosis variables. PCT using the T-bag SRD led to a significant decrease in aggregation capacity with collagen and thrombin and a significant increase in plasma LDH, whereas no differences for the Wafer SRD were found. CONCLUSION: PCT using the experimental T-bag SRD led to a significant decrease in platelet function. However, the commercially available Wafer SRD had only minor in vitro effects on the quality of the platelets.

Apoptosis↗

Simplification of the diagnostic management of suspected deep vein thrombosis.

BACKGROUND: The standard diagnostic approach in patients with suspected deep vein thrombosis is to repeat the compression ultrasonography after 1 week in all patients with an initial normal result. We hypothesized that a normal finding of a D-dimer assay safely obviates the need for repeated ultrasonography. In addition, we evaluated the potential value of a pretest probability assessment for this purpose. METHODS: At presentation, consecutive outpatients with suspected thrombosis underwent independent assessment by means of ultrasonography of the proximal veins, a whole-blood D-dimer assay, and a pretest clinical model. Patients with normal ultrasonographic findings and an abnormal D-dimer assay result were scheduled for repeated ultrasonography. We evaluated the incidence of symptomatic venous thromboembolic complications during a 3-month follow-up, and the value of clinical pretest probability with ultrasonography or D-dimer assay in scenario analyses. RESULTS: We studied 1756 patients with prevalence of thrombosis of 22%. At entry, results of the D-dimer assay and ultrasonography were normal in 828 patients (47%). Of these, 6 returned with confirmed symptomatic venous thromboembolism (complication rate, 0.7%; 95% confidence interval [CI], 0.3%-1.6%). Repeated ultrasonography was avoided in 61% of the patients with an initial normal test result. Scenario analyses disclosed that the complication rate was 1.6% (95% CI, 0.8%-2.6%) in those with a low clinical pretest probability and a normal result of ultrasonography at referral, whereas this figure was 1.8% (95% CI, 0.9%-3.3%) in patients with a low clinical probability result and a normal result of the D-dimer assay at referral. CONCLUSIONS: It is safe to withhold repeated ultrasonography in patients with suspected deep vein thrombosis who have normal results of ultrasonograpy and the SimpliRED D-dimer assay at presentation. The combination of a low clinical pretest probability with a normal result of compression ultrasonography or the D-dimer assay appears to be equally safe in refuting the diagnosis of deep vein thrombosis.

Adolescent↗