System performance evaluation of refractive surgical lasers: a mathematical approach.

A study was conducted for the purpose of improving the designs of the next generation of refractive surgical laser systems. Two common refractive laser systems, variable-spot scanning (type A) and small-spot scanning (type B), are discussed by identifying sources of error that could adversely affect the capability of these lasers to accurately produce complex, customized wavefront guided ablations. A mathematical model was used to construct a laser simulator that models the two common laser systems in terms of the root-mean-square error. Error sources from ablation profile fitting, ablation registration, eye tracking, and the laser delivery system are compared, and the relative contribution of each to the overall system error is analyzed. This system-level analysis can be helpful to the improvement of both laser systems.

Computer Simulation↗

Shack-Hartmann-Based wavefront analyzer for calibrating excimer lasers.

PURPOSE: Currently, refractive surgical excimer laser systems are calibrated by ablating plastic lenses, which are measured by lensometer and analyzed by a technician. The accuracy of this method is approximately 0.25 diopters (D) in sphere and cylinder power. Theoretically, objective calibration using wavefront technology would be significantly more accurate, thereby improving surgical outcomes. This study describes a Shack-Hartmann-based instrument, which has been developed to measure ablated plastic lenses for calibration and quality control of the excimer laser. METHODS: A calibration instrument comprising an LED source at 640 nm, a lenslet array, beam-guiding optics, and a CCD camera was designed to perform full wavefront analysis. The measurement plane is conjugate to the lenslet array plane, and the diameter of the pupil is 5 mm. Accuracy was determined by measuring a set of well-calibrated spherical and cylindrical glass lenses. Plastic lenses were ablated, and high-precision measurements were performed by surface profile scanner. RESULTS: In the power range of -6.00 to +4.00 D, repeatability exceeded 0.01 D, accuracy of measurement exceeded 0.04 D, and 10 for the axis of cylinder lenses. The measurement of excimer-ablated plastic lenses agreed with high-precision surface profile scanner measurements within 0.10 D, and repeatability exceeded 0.01 D. CONCLUSIONS: Wavefront technology-based, high-precision measurement of calibration lenses can more accurately set the energy of the excimer laser, which enhances the accuracy of refractive laser correction. In automating calibration, the new instrument removes operator subjectivity and decreases the time needed for calibration.

Calibration↗