PubMed Health⌕ Search

Biomedical subjects

Erik K Paulson

Publications and source records attributed to Erik K Paulson.

At least 19 recordsLinked to original sources

Abdominal pain: coronal reformations from isotropic voxels with 16-section CT--reader lesion detection and interpretation time.

PURPOSE: To retrospectively assess if reader detection of intraabdominal pathologic findings on coronal reformations from isotropic voxels at 16-section computed tomography (CT) was similar to reader detection on transverse scans. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant study, and a waiver of informed consent was obtained. Twenty-nine consecutive patients (12 men, 17 women; mean age, 48 years; age range, 21-93 years) with abdominal pain underwent 16-section CT with coronal reformations. Eight independent readers reviewed randomized scans (transverse and coronal) and identified pathologic findings in multiple organ systems. Timing for each interpretation was recorded. One month later, readers reviewed the scan reformatted in the other imaging plane. Agreement between transverse and coronal scans was measured by using Cohen kappa coefficients. RESULTS: Agreement was moderate to near perfect between transverse and coronal interpretations for intraabdominal anatomic and pathologic findings (kappa=0.59-1.00). For transverse interpretations, more thoracic pathologic findings were noted than for coronal interpretations; for coronal interpretations, more lymph nodes were noted than for transverse interpretations. Mean transverse interpretation time was 4.9 minutes+/-1.1 (standard deviation) (range, 2.9-6.5 minutes); mean coronal interpretation time was 5.1 minutes+/-0.8 (range, 3.3-6.7 minutes). For each reader, there was no statistically significant difference in interpretation time between transverse and coronal scans (P=.06). CONCLUSION: With regard to the presence of intraabdominal pathologic findings, coronal reformations from isotropic voxels are similar to transverse scans in terms of interpretation time and reader agreement.

Abdominal Neoplasms↗

MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 Tesla.

To evaluate whether clips from prior cholecystectomy impair image quality during magnetic resonance cholangiography (MRC) at 3 Tesla (T) compared with 1.5 T, surgical clips were embedded in a gel phantom and positioned at predefined distances from a fluid-filled tube designed to simulate the bile duct. The maximum clip distance was noted where susceptibility artifacts obscured the fluid-filled tube at 1.5 T and 3 T. Susceptibility artifact size was calculated for each sequence within each magnet class. In vivo analysis included 42 patients postcholecystectomy who underwent MRC at either 1.5 T or 3 T. In vitro, mean area of susceptibility artifacts was 104 mm2 on 3-T and 75 mm2 on 1.5-T MR imaging (MRI). While surgical clips within a 2-mm range impaired visualization of the fluid-filled tube on 1.5-T MRI, this range increased to 4 mm on 3-T MRI. In vivo, MRC image quality was impaired by susceptibility artifacts in three of 21 cases at 3 T and in two of 21 cases at 1.5 T. Overall, biliary pseudo-obstructions due to susceptibility artifacts from cholecystectomy surgical clips were not substantially more common on 3-T MRC in clinical practice, and patients with a history of prior cholecystectomy should not be excluded from a 3-T MRC.

Adult↗

Causes of errors in polyp detection at air-contrast barium enema examination.

PURPOSE: To retrospectively determine the cause of errors in air-contrast barium enema (ACBE) examination for detection of polyps 6 mm or larger. MATERIALS AND METHODS: The study had institutional review board approval. Informed consent was waived for this HIPAA-compliant study. ABCE findings in 41 subjects with 56 missed polyps were evaluated by two radiologists to determine if the cause of errors was perceptual or technical. A comparison was made between total number of polyps in the proximal and distal colon and those missed at each location (Fisher exact test). The 288 ACBE examinations were assessed on a scale of 0-4 (0, excellent; 4, very poor) for six colonic segments (paired t test). RESULTS: Of 17 polyps 1 cm or larger not detected in 15 subjects, 11 (65%) were missed because of technical errors and six (35%) because of perceptual errors. Eight (72%) technical and four (67%) perceptual errors occurred proximal to the splenic flexure. One 3.5-cm cecal carcinoma was not diagnosed prospectively (perceptual error). Of 39 6-9-mm polyps not detected in 26 subjects, 35 (90%) were missed because of technical errors and four (10%) because of perceptual errors. Eighty percent of technical and 75% of perceptual errors were in the proximal colon. When the proportion of polyps in the proximal and distal colon was compared, 22 (63%) of 35 polyps in the distal colon and 15 (26%) of 58 in the proximal colon were detected (P = .0009). There were no detectable differences in the quality of studies in subjects whose polyps were detected and subjects whose polyps were missed (P > .05). CONCLUSION: Technical errors were more common than perceptual errors. The majority of missed polyps were in the proximal colon. Detection rates of polypoid lesions might increase if the quality of ACBE examination can be improved, especially in the proximal colon.

Adult↗

Prospective comparison of patient experience with colon imaging tests.

PURPOSE: Patient experience varies with the currently available colon imaging tests, including air contrast barium enema, computed tomographic colonography, and colonoscopy. We examined differences in patient experience with colon imaging tests and whether they varied with gender, age, and race. SUBJECTS AND METHODS: Patients with fecal occult blood, hematochezia, iron-deficiency anemia, or a family history of colon cancer underwent air contrast barium enema followed 7 to 14 days later by computed tomographic colonography and colonoscopy. Validated patient experience questionnaires that measured the experience for each test and a separate questionnaire that obtained an overall summary measure were administered after testing. Eleven patient experiences including pain, embarrassment, difficulty with bowel preparation, and satisfaction with tests were examined. RESULTS: A total of 614 subjects completed all 3 imaging tests. The test most patients were willing to repeat was colonoscopy; it also was reported to be the least painful procedure. Patients were least satisfied with air contrast barium enema, and fewer would undergo air contrast barium enema compared with computed tomographic colonography or colonoscopy. There were limited racial and gender differences in perceptions of the tests. Younger adults perceived air contrast barium enema to be more painful than older adults. CONCLUSION: Taking into account a wide variety of patient experience measures, patients preferred colonoscopy to air contrast barium enema and computed tomographic colonography. This finding has important implications for physicians considering different colon imaging tests.

Barium Sulfate↗

A randomized comparison of EUS-guided FNA versus CT or US-guided FNA for the evaluation of pancreatic mass lesions.

BACKGROUND: Diagnosing pancreatic cancer by EUS-FNA is a potentially appealing alternative to percutaneous biopsy. AIM: To compare EUS-FNA with CT or US-guided FNA for diagnosing pancreatic cancer. DESIGN: Single center, prospective, randomized, cross-over. SETTING: Duke University Medical Center. POPULATION: Eighty-four patients referred with suspicious solid pancreatic mass lesions randomized to CT/US-FNA (n = 43) or EUS-FNA (n = 41). INTERVENTION: Patients underwent an imaging procedure/FNA. If cytology was nondiagnostic, cross over to the other modality was offered. Final outcome was determined by clinical follow-up every 6 months for 2 years and/or surgical pathology for patients with negative FNA. MAIN OUTCOME MEASUREMENTS: Sensitivity and accuracy of EUS-FNA versus CT/US-FNA for pancreatic cancer. RESULTS: There were 16 true positive (TP) by CT/US-FNA and 21 TP by EUS-FNA. Sixteen of the 20 CT/US-FNA negative patients crossed over to EUS-FNA; 12 underwent FNA, 4 had no mass at EUS. Seven of the 12 had positive EUS-FNA. Eight EUS-FNA negative crossed over to CT/US; 4 had no mass at CT/US, 3 remained true negative throughout follow-up, 1 had chronic pancreatitis at surgery. The sensitivity of CT/US-FNA and EUS-FNA for detecting malignancy was 62% and 84%, respectively. A comparison of the accuracy for CT/US-FNA and EUS-FNA was not statistically significant (P = .074, chi(2)). LIMITATIONS: Failure to meet target enrollment resulted in an inability to demonstrate a statistically significant difference between the 2 modalities. CONCLUSIONS: EUS-FNA is numerically (though not quite statistically) superior to CT/US-FNA for the diagnosis of pancreatic malignancy.

Adenocarcinoma↗

Abdominal MR imaging at 3T.

Body MR imaging at 3T is in its infancy, and should improve substantially over the next several years. Radiologists need to be aware of several limitations that are based on the laws of physics: Overall, the gain in SNR at 3T will be less than twofold (without protocol alteration) compared with a standard 1.5T MR system because of the increase in T'I'1 at ultra high field. Typically, the gain in SNR is greater in T2-weighted sequences than in TI-weighted sequences, because longer TRs allow for a more complete recovery of the longitudinal magnetization, and T2 is independent of Bo. Thus, for example, patients who are referred for an MR cholangiography may benefit from an ultrahigh-field MR examination. Chemical shift artifacts of the first kind are twice as large in ultrahigh-field MR imaging compared with standard 1.5T MR imaging. Conversely, chemical shift artifacts of the second kind do not increase in size, although the timing is altered. The increased difference in resonant frequency between water and fat at 3T also is advantageous because it allows for a better separation of the fat and water peak during MR spectroscopy, and allows better or faster fat suppression using chemical shift techniques, such as fat saturation or water excitation. Susceptibility artifacts are approximately twice as large by volume on 3T MR imaging. Although patients who are referred for a "colon" study may be challenging at ultrahigh field, the search for "gas" (eg, free air or pneumobilia) should be easier. Patients with metal implants should undergo an MR examination at 3T only if the metal-containing device specifically has been proved to be MR safe at this field strength. Usually, standing wave and conductivity effects are not seen in body imaging at a field strength of 1.5T. At 3T, these artifacts are most pronounced in pregnant women in the sec-ond and third trimester, because of the large amount of conductive amniotic fluid and the increased size of the abdomen. Therefore, fetal MR imaging generally should not be performed at 3T because of these artifacts and the increased safety concerns. The same holds true for patients with a large amount of ascites, who also are not well suited for an ultrahigh-field MR examination. Except as noted above, most patients can undergo an abdominal MR imaging study at 3T with a reasonable outcome in terms of image quality.

Abdomen↗

Optimization of multiplanar reformations from isotropic data sets acquired with 16-detector row helical CT scanner.

Institutional review board approval and waiver of consent were obtained for the patient component of this retrospective HIPAA-compliant study. By using an anthropomorphic phantom and metal oxide semiconductor field effect transistor detectors, radiation dose was determined for one eight-detector row and two 16-detector row computed tomographic (CT) protocols. A custom phantom was scanned by using the three protocols to identify isotropy. Contrast-to-noise ratios (CNRs) were determined for the same protocols by using a third phantom. Seven patients had undergone isotropic 16-detector row CT of the abdomen and pelvis. Anonymized coronal reformations at various thicknesses were ranked qualitatively by three radiologists. Effective dose equivalents were similar for the eight- and 16-detector row protocols. When transverse and coronal reformations of data acquired in the custom phantom were compared, coronal reformations obtained with the 16-detector row and 0.625-mm section thickness protocol were found to be nearly identical to the transverse image for all sets of line pairs. CNRs were consistently highest on 5-mm-thick coronal reformations (CNR range, 1.2-3.3). For qualitative assessment, 2- and 3-mm-thick coronal reformations were consistently preferred.

Adult↗

Postprocedure sepsis in imaging-guided percutaneous hepatic abscess drainage: how often does it occur?

OBJECTIVE: This retrospective study was conducted to determine the incidence of sepsis at our institution after percutaneous drainage of a hepatic abscess. MATERIALS AND METHODS: Thirty-three patients with a hepatic abscess treated using percutaneous aspiration and drainage from 1995 to 2000 were identified from a search of the interventional database. The patients' charts and CT images were reviewed independently by two radiologists for clinical presentation, relevant medical history, pre- and postprocedure antibiotic regimens, and clinical course after percutaneous aspiration and drainage. The preprocedure images were reviewed for the location and morphology of the abscess. The procedure details including percutaneous approach, guidance technique, catheter size, and immediate postprocedure complications were reviewed. RESULTS: Of the 33 patients, 14 patients underwent only needle aspiration of the abscess. In six (43%) of these 14 patients, the abscesses resolved with aspiration and appropriate antibiotic treatment alone. Eight (57%) of the patients who had aspiration of the abscess initially went on to have drainage catheters placed within a 72-hr period. Nineteen patients had drainage catheters placed from the onset. Of these, 17 patients (89%) had abscess resolution. Of the 27 patients who had catheters placed, a total of seven patients (26%) developed clinical symptoms of septicemia after catheter placement, but all patients, at least initially, responded to supportive treatment. Two patients died from septicemia 3-6 weeks after the procedure. None of the patients who underwent aspiration only developed postprocedure septicemia. CONCLUSION: After placement of a percutaneous drainage catheter in a hepatic abscess, there is a significant risk (26%) of postprocedure sepsis. Although it appears to be a random and unpredictable event in our small series, interventional radiologists and referring physicians should be aware of the risk of sepsis after percutaneous drainage of hepatic abscess.

Adult↗

Radiation dose to the fetus from body MDCT during early gestation.

OBJECTIVE: The purpose of our study was to determine radiation dose to the fetus at early gestation when contemporary MDCT scanners are used for common clinical indications. MATERIALS AND METHODS: Anthropomorphic phantoms were constructed to reflect a pregnant woman. Thermoluminescence dosimeters (TLDs) and metal oxide semiconductor field effect transistor (MOSFET) detectors were placed in appropriate locations to determine real-time radiation exposure to the fetus at 0 and 3 months' gestation. Imaging was performed on a 16-MDCT scanner using current institutional CT protocols: renal stone (140 kVp, 160 mA, rotation time of 0.5 sec, 16 x 0.625 mm), appendix (140 kVp, 340 mA, rotation time of 0.5 sec, 16 x 0.625 mm), and pulmonary embolus (140 kVp, 380 mA, rotation time of 0.8 sec, 16 x 1.25 mm). RESULTS: The radiation dose to the fetus at 0 and 3 months, respectively, was as follows: renal stone protocol, 0.8-1.2 and 0.4-0.7 cGy; appendix protocol, 1.52-1.68 and 2-4 cGy; and pulmonary embolus protocol, 0.024-0.047 and 0.061-0.066 cGy. CONCLUSION: Radiation doses to the fetus from institutional MDCT protocols that may be used during pregnancy (for pulmonary embolus, appendicitis, and renal colic) are below the level thought to induce neurologic detriment to the fetus. Imaging the mother for appendicitis theoretically may double the fetal risk for developing a childhood cancer. Radiation doses to the fetus from pulmonary embolus chest CT angiography are of the same magnitude as ventilation-perfusion (V/Q) scanning.

Female↗

Radiation dose to the female breast from 16-MDCT body protocols.

OBJECTIVE: The objective of our study was to determine the radiation dose to the female breast from current 16-MDCT body examinations. MATERIALS AND METHODS: Metal oxide semiconductor field effect transistor (MOSFET) detectors were placed in four quadrants of the breast of a female-configured anthropomorphic phantom to determine radiation dose to the breast. Imaging was performed on a 16-MDCT scanner (LightSpeed, GE Healthcare) using current clinical protocols designed to assess pulmonary embolus (PE) (140 kVp, 380 mA, 0.8-sec rotation, 16 x 1.25 mm collimation), appendicitis (140 kVp, 340 mA, 0.5-sec rotation, 16 x 0.625 mm collimation), and renal calculus (140 kVp, 160 mA, 0.5-sec rotation, 16 x 0.625 mm collimation). RESULTS: Radiation dose to the breast ranged from 4 to 6 cGy for the PE protocol and up to 1-2 cGy in the inferior aspect of the right breast and lateral aspect of the left breast for the appendicitis protocol. The renal calculus protocol yielded less than 150 microGy absorbed breast dose. CONCLUSION: Current clinical chest and abdomen protocols result in vairable radiation doses to the breast. The magnitude of exposure may have implications for imaging strategies.

Breast↗

Comparison of radiologists and technologists in the performance of air-contrast barium enemas.

OBJECTIVE: The purpose of this study was to determine whether the rate of polyp detection and the quality of air-contrast barium enema (ACBE) procedures performed by technologists differ from those performed by radiologists. CONCLUSION: Our results showed that well-trained certified technologists can perform ACBE similar in overall quality and accuracy to ACBE performed by attending physicians and residents. Training technologists to perform ACBE may help to alleviate the radiology staffing shortage in the United States.

Air↗

Small-bowel obstruction: coronal reformations from isotropic voxels at 16-section multi-detector row CT.

PURPOSE: To retrospectively assess the added value of coronal reformations of the abdomen and pelvis from isotropic voxels by using 16-section multi-detector row computed tomography (CT) for the diagnosis of small-bowel obstruction (SBO). MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board of this medical center with a waiver of informed consent. One hundred consecutive patients (40 men and 60 women; mean age, 55 years) suspected of having SBO and abdominal pain underwent 16-section multi-detector row CT with coronal reformations. Twenty-nine patients had a final diagnosis of SBO, and 71 patients did not. Three independent readers blinded to the diagnosis interpreted the CT scout scan, then transverse scans alone, and then transverse plus coronal scans for the presence of SBO and abnormal wall enhancement. Confidence was scored with a 1-5 scale (1 = absent, 5 = present). RESULTS: Mean sensitivity and specificity of CT scout alone, transverse CT alone, and transverse plus coronal CT for the diagnosis of SBO were 88% and 86%, 87% and 87%, and 87% and 90%, respectively (not significant). In patients without SBO, transverse plus coronal CT enhanced confidence in the exclusion of SBO (P = .01). In patients with SBO, transverse plus coronal CT enhanced confidence in the diagnosis of SBO and identification of abnormal wall enhancement (P = .01). CONCLUSION: Transverse 16-section multi-detector row CT data sets are an excellent test for the diagnosis of SBO, while the addition of coronal reformations obtained from these isotropic data sets adds confidence to the diagnosis and exclusion of SBO.

Adult↗

Efficacy and safety of MR imaging with liver-specific contrast agent: U.S. multicenter phase III study.

PURPOSE: To assess prospectively the efficacy and safety of postcontrast magnetic resonance (MR) imaging with gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) compared with that of precontrast MR imaging in patients who are known to have or are suspected of having liver lesions and who are scheduled for hepatic surgery. MATERIALS AND METHODS: Investigational review board approval and written informed consent were obtained. HIPAA went into effect after data collection. A total of 172 patients were enrolled. After precontrast MR imaging, 169 patients (94 men, 75 women; mean age, 61 years; age range, 19-84 years) received an intravenous bolus of 25 micromol/kg Gd-EOB-DTPA and underwent dynamic gradient-recalled-echo and delayed MR imaging 20 minutes after injection. Arterial and portal phase computed tomography (CT) were performed within 6 weeks of MR imaging. The standard of reference was surgery with intraoperative ultrasonography (US) and biopsy and/or pathologic evaluation of resected liver segments and/or 3-month follow-up of nonresected segments if intraoperative US was not available. Three blinded reviewers and unblinded site investigators identified liver lesions on segment maps. The Wilcoxon signed rank test was used to compare differences in per-patient sensitivity of precontrast and postcontrast MR images. Adverse events were recorded, and patient monitoring and laboratory assay were performed at time of injection and up to 24 hours after contrast material administration. RESULTS: At MR imaging, 316 lesions were identified in 131 patients. In 77% (P = .012), 72% (P = .15), and 71% (P = .027) of patients for readers 1, 2, and 3, respectively, more lesions were seen at precontrast and postcontrast MR imaging combined than at precontrast MR imaging alone. Sensitivity values for blinded readings were significantly greater at postcontrast MR imaging than at precontrast MR imaging for two of three blinded readers. For all blinded readers, combined precontrast and postcontrast MR images showed no difference in sensitivity compared with helical CT scans. The use of MR imaging, however, yielded fewer patients with at least one false-positive lesion (37%, 31%, and 34% of patients for readers 1, 2, and 3, respectively) than did helical CT (45%, 36%, and 43% of patients for readers 1, 2, and 3, respectively). CONCLUSION: Compared with precontrast MR imaging, postcontrast MR imaging with Gd-EOB-DTPA demonstrated improved sensitivity for lesion detection in the majority of blinded readers, with no substantial adverse events.

Adult↗

Acute appendicitis: added diagnostic value of coronal reformations from isotropic voxels at multi-detector row CT.

PURPOSE: To assess retrospectively the added value of coronal reformations from isotropic voxels obtained with 16-section multi-detector row computed tomography (CT) of the abdomen and pelvis in patients with suspected acute appendicitis. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was waived. One hundred consecutive patients (21 men, 79 women; mean age, 38 years) with suspected appendicitis underwent 16-section multi-detector row CT (section thickness, 0.625 mm; pitch, 1.75; table speed, 35 mm/sec [17.5 mm per rotation, two rotations]; and gantry speed, 0.5 second per rotation), with coronal reformations. Twenty-four patients had appendicitis; 76 did not. Protocol included 150 mL oral iopamidol administered at 3 mL/sec. Transverse scans were reconstructed with 5-mm-thick sections at 5-mm intervals and 0.625-mm-thick sections at 0.625-mm intervals. The second data set was reformatted coronally, with 3-mm-thick sections at 5-mm intervals. Three independent blinded readers interpreted transverse scans alone and then coronal scans; confidence in visualization of any portion of appendix, entire appendix, wall thickening, distention, inflammation, fluid, and appendicitis was scored with 1-5 scale. Sensitivity and specificity were determined for each reader and compared by means of signed rank test. Agreement between readers was determined with kappa statistic. Differences in mean confidence ratings for each finding were determined with Wilcoxon signed rank test. RESULTS: Mean sensitivity and specificity for all three readers together were 96% and 95% for transverse reformations alone and 95% and 94% for combined transverse and coronal reformations (not significant), respectively. Visualization rates for portion or all of appendix were higher for combined transverse and coronal reformations than for transverse reformations alone (higher mean confidence scores: 0.23 higher [P < .009] and 0.51 higher [P < .001], respectively). In patients without appendicitis, transverse and coronal reformations together enhanced confidence in exclusion of wall thickening, distention, and fluid (lower confidence scores: 0.21 lower [P < .001], 0.17 lower [P < .01], 1.00 lower [P < .001], respectively). Combined transverse and coronal reformations enhanced confidence in identification of appendix in mean of 57 patients. Combined transverse and coronal scans helped exclude appendicitis in mean of 38 patients and aided diagnosis of it in 15. CONCLUSION: Sixteen-section multi-detector row CT transverse and coronal reformations are equally sensitive and specific for diagnosis of appendicitis. Coronal reformations improve confidence in visualization of appendix (whether diseased or normal) and in diagnosis or exclusion of appendicitis.

Acute Disease↗

Significance of histological response to preoperative chemoradiotherapy for pancreatic cancer.

BACKGROUND: Neoadjuvant (preoperative) chemoradiotherapy (CRT) for pancreatic cancer offers theoretical advantages over the standard approach of surgery followed by adjuvant CRT. We hypothesized that histological responses to CRT would be significant prognostic factors in patients undergoing neoadjuvant CRT followed by resection. METHODS: Since 1994, 193 patients with biopsy-proven pancreatic adenocarcinoma have completed neoadjuvant CRT, and 70 patients have undergone resection. Specimens were retrospectively examined by an individual pathologist for histological responses (tumor necrosis, tumor fibrosis, and residual tumor load) and immunohistochemical staining for p53 and epidermal growth factor receptor. Factors influencing overall survival were analyzed with the Kaplan-Meier (univariate) and Cox proportional hazards (multivariate) methods. RESULTS: The estimated overall survival (median +/- SE) in the entire group of patients undergoing resection was 23 +/- 4.2 months, with an estimated 3-year survival of 37% +/- 6.6% and a median follow-up of 28 months. Complete histological responses occurred in 6% of patients. Overexpression of p53 was more common in patients with large residual tumor loads. Tumor necrosis was an independent negative prognostic factor, as were positive lymph nodes, a large residual tumor load, and poor tumor differentiation. CONCLUSIONS: Histological response to neoadjuvant CRT--as measured by residual tumor load--may be useful as a surrogate marker for treatment efficacy. Characterization of the tumor cells that survive neoadjuvant CRT may help us to identify new or more appropriate targets for systemic therapy.

Adenocarcinoma↗

MDCT of abdominal wall hernias: is there a role for valsalva's maneuver?

OBJECTIVE: Our objective was to evaluate the role of Valsalva's maneuver during MDCT for the diagnosis and characterization of abdominal wall hernias. SUBJECTS AND METHODS: From September 2002 to May 2003, 100 consecutive patients (37 men and 63 women; mean age, 53 years) with suspected anterior abdominal wall hernias underwent 4-, 8-, or 16-MDCT with and without Valsalva's maneuver. Patients received both oral and IV contrast material. On a workstation, three independent reviewers evaluated each scan obtained during rest and during Valsalva's maneuver for the following parameters: anteroposterior (AP) diameter of the abdomen; presence, location, and contents of the hernia; and transverse diameter of the fascial defect. The scans were compared to assess for changes in hernia size and contents and to determine whether the hernia would have been overlooked without Valsalva's maneuver. Fisher's exact test, the McNemar test, and Cohen's kappa coefficient were used to assess for significant differences. RESULTS: The three reviewers identified a mean of 72 abdominal wall hernias (72%). The reviewers agreed (kappa = 0.723) with respect to the presence of a hernia. AP diameters increased an average of 1.33 cm during Valsalva's maneuver (p < 0.001). The transverse diameter of the fascial defect increased an average of 0.66 cm and the AP diameter of the hernia sac increased an average of 0.79 cm during Valsalva's maneuver (p < 0.001). Fifty percent of the hernias became more apparent with Valsalva's maneuver. Ten percent of the hernias could be detected only on the scan obtained during Valsalva's maneuver. Conversely, in no patients was the hernia detected only on the rest scan. CONCLUSION: As opposed to scans obtained at rest, scans obtained during Valsalva's maneuver aid in the detection and characterization of suspected abdominal wall hernias. A single scan obtained during Valsalva's maneuver is sufficient to detect 100% of anterior abdominal wall hernias identified on CT.

Adult↗