PubMed Health⌕ Search

Biomedical subjects

Erik M Pedersen

Publications and source records attributed to Erik M Pedersen.

7 recordsLinked to original sources

Spiral coronary angiography using a blood pool agent.

PURPOSE: To experimentally investigate the optimum dose of an iron-oxide-based blood pool agent for spiral coronary MR angiography (MRA), and the difference between single and multiple spiral excitations in each cardiac cycle. MATERIALS AND METHODS: Images using single and triple spiral excitations in each cardiac cycle were obtained in late diastole of the left main coronary artery in eight pigs following an inversion prepulse. Measurements were obtained before and after injection of increasing doses of an iron oxide blood pool agent (Clariscan) corresponding to concentrations of 0.8, 2.2, and 3.9 mg Fe/kg BW. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. RESULTS: For 0.8 mg Fe/kg BW relative to precontrast values, a significant increase was observed for both one (SNR: 2.3, CNR: 3.8) and three (SNR: 1.4, CNR: 2.2) excitations (P < 0.01). When the dose was increased from 0.8 mg Fe/kg BW to 2.2 mg Fe/kg BW, only the SNR (P < 0.01) increased further. Significantly higher CNR (1.6-1.8) and SNR (1.4-1.6) values were seen for one excitation relative to three excitations at all concentrations (P < 0.05). CONCLUSION: At low concentrations, an iron oxide blood pool agent can increase SNR and CNR significantly with both single excitation and triple excitations using an inversion-prepared spiral acquisition scheme. At higher concentrations, T2* effects reduce image quality.

Animals↗

Strut chordal-sparing mitral valve replacement preserves long-term left ventricular shape and function in pigs.

OBJECTIVE: Mitral valve replacement with preservation of the entire subvalvular apparatus entails superior postoperative left ventricular function compared with other techniques. However, this option is often not possible because of valve pathology. We hypothesized that preservation of only 4 mitral valve secondary ("strut") chordae would be functionally and geometrically equivalent to total valve preservation in the long-term setting. In a porcine mitral valve replacement model we investigated the long-term effects of 3 surgical techniques on left ventricular function and geometry: (1) total preservation of the native valve, (2) strut chordal preservation, and (3) total excision of the subvalvular apparatus. METHODS: Forty 60-kg pigs were randomized to 1 of the 3 techniques. Global and regional left ventricular function and dimensions were assessed with cardiovascular magnetic resonance and conductance catheter 90 days after mitral valve replacement. Groups were compared by multivariate analysis of variance. RESULTS: There was no overall difference between groups 1 and 2. Group 3 animals had (1) greater base-apex diastolic and systolic lengths, and smaller short-axis diameters, and (2) lower sphericity indices, and greater base-apex and short-axis fractional shortening than groups 1 and 2. Regional analysis showed slimming and elongation to occur primarily in the basal left ventricular segments. Left ventricular contractility and hemodynamic parameters did not differ between groups. CONCLUSIONS: Strut chordal preservation was equivalent to total valve preservation during mitral valve replacement, whereas total chordal resection caused significant left ventricular slimming with compensatory increases in fractional shortening. Therefore, to preserve left ventricular geometry, special attention must be paid to maintain the valvular-ventricular continuity through the strut chordae during mitral valve replacement. This concept may have important therapeutic implications for chordal-sparing mitral valve replacement.

Animals↗

Accelerated dynamic Fourier velocity encoding by exploiting velocity-spatio-temporal correlations.

OBJECTIVE: To describe how the information content in a Fourier velocity encoding (FVE) scan can be transformed into a very sparse representation and to develop a method that exploits the compactness of the data to significantly accelerate the acquisition. MATERIALS AND METHODS: For validation, fully sampled FVE datasets were acquired in phantom and in vivo experiments. Fivefold and eightfold acceleration was simulated by using only one fifth or one eighth of the data for reconstruction in the proposed method based on the k-t BLAST framework. Reconstructed images were compared quantitatively to those from the fully sampled data. RESULTS: Velocity spectra in the accelerated datasets were comparable to the spectra from fully sampled datasets. The detected peak velocities remained accurate even at eightfold acceleration, and the overall shape of the spectra was well preserved. Slight temporal smoothing was seen in the accelerated datasets. CONCLUSION: A novel technique for accelerating time-resolved FVE scan is presented. It is possible to accelerate FVE to acquisition speeds comparable to a standard time-resolved phase-contrast scan.

Algorithms↗

Wall shear rates differ between the normal carotid, femoral, and brachial arteries: an in vivo MRI study.

PURPOSE: To investigate wall shear rates in vivo in the common carotid, brachial, and superficial femoral arteries using very high resolution magnetic resonance imaging (MRI) phase contrast measurements. MATERIALS AND METHODS: Mean, maximum, and minimum wall shear rate and an oscillatory shear index were measured for 20 volunteers, aged 23.3 +/- 1.9 years, in the three arteries, using phase contrast imaging with 0.0625 mm2 resolution and three-dimensional paraboloid fitting. RESULTS: The superficial femoral artery had the lowest mean (130.3 +/- 13.1 second(-1)), maximum (735.8 +/- 32.4 second(-1)), and minimum (-224.5 +/- 17.0 second(-1)) wall shear rate, as well as the highest oscillatory shear index (0.21 +/- 0.02). All values were significantly different (P < 0.05) from both the brachial artery and the common carotid artery values. The highest mean (333.3 +/- 13.6 second(-1)) and minimum (117.9 +/- 24.5 second(-1)) wall shear rates and the lowest oscillatory shear index (0 +/- 0) were found in the common carotid artery. CONCLUSION: It is possible to measure wall shear rate in vivo in different arteries using MRI with very high resolution. The findings exhibit the in vivo environment of wall shear rates and suggest a nonuniform distribution of wall shear rates throughout the arterial system.

Adult↗

On the influence of training data quality in k-t BLAST reconstruction.

This work investigated how the quality of prior information (i.e., data acquired during the training stage) influences k-t BLAST reconstruction. The impact of several factors, such as the amount of training data, the presence of spatial misregistration in the training data, and the effects of filtering, was investigated with simulations and in vivo data. It is shown that k-t BLAST outperforms sliding window reconstruction, even with very limited training data. By increasing the amount of training data, reconstruction error continues to decrease, albeit by a diminishing amount. However, an increased amount of training data also increases susceptibility to misregistration of the training data. Filtering of the training data with the goal of reducing truncation artifacts had only minor impact on reconstruction errors. Considering the balance among obtaining the most benefit from the training data, minimizing susceptibility to misregistration, and keeping data acquisition to a minimum, it is concluded that in cardiac imaging the training datasets should be limited to 10-20 profiles in k-space for a typical field of view. The training data may be acquired in a separate breathhold without much penalty, if care is taken to minimize misregistration, such as with a navigator.

Adult↗

Arterial MR imaging phase-contrast flow measurement: improvements with varying velocity sensitivity during cardiac cycle.

To reduce noise in velocity images of magnetic resonance (MR) phase-contrast measurements, the authors implemented and evaluated a pulse sequence that enables automatic optimization of the velocity-encoding parameter V(enc) for individual heart phases in pulsatile flow on the basis of a rapid prescan. This sequence was prospectively evaluated by comparing velocity-to-noise ratios with those from a standard MR flow scan obtained in the carotid artery in eight volunteers. This sequence was shown to improve velocity-to-noise ratios by a factor of 2.0-6.0 in all but the systolic heart phase and was determined to be an effective technique for reducing noise in phase-contrast velocity measurements.

Adult↗

Intraventricular dispersion and temporal delay of early left ventricular filling after acute myocardial infarction. Assessment by magnetic resonance velocity mapping.

This article aims to describe early left ventricular diastolic inflow using magnetic resonance velocity mapping in patients with recent acute myocardial infarction and in normal volunteers. Magnetic resonance velocity mapping was performed in a long axis plane through the hearts of 46 patients with recent, first time acute myocardial infarction and 43 age-matched normal volunteers. The peak velocities at six levels of the early diastolic inflow stream were recorded. A velocity index was calculated as the peak velocity in each position relative to the peak velocity at the mitral leaflet tips. Also, the temporal delay of velocity propagation was computed. Velocity index 4 cm downstream of mitral leaflet tips was lower in the acute myocardial infarction group (0.42 (0.17)) (mean (SD)) compared to controls (0.59 (0.25)) (p < 0.001). Temporal delay in the same position was longer in the acute myocardial infarction group (62 (67) ms) than in controls (32 (39) ms) (p < 0.02). Blood flow patterns in patients after acute myocardial infarction were characterized by increased dispersion of velocities and increased temporal delay of velocity propagation, probably reflecting impaired active left ventricular relaxation. Intraventricular flow measurements constitute a promising new technique for non-invasive assessment of left ventricular diastolic function.

Adult↗