Improved quantification in 123I cardiac SPECT imaging with deconvolution of septal penetration.

OBJECTIVES: (123)I is becoming an important radionuclide for cardiac imaging. Multiple, low-abundance, high-energy photons associated with (123)I imaging can cause septal penetration in the collimators and degrade quantification of the (123)I cardiac uptake. This study presents a method for the deconvolution of septal penetration (DSP) for improving quantification in (123)I cardiac single photon emission computed tomography (SPECT). METHODS: Distance-dependent point spread functions were measured for low-energy high-resolution collimators on a dual-head SPECT system. The measured point spread functions were used in two-dimensional (2-D) and three-dimensional (3-D) models of the collimator response, respectively. 2-D DSP and 3-D DSP were then developed and implemented using iterative reconstruction. A cardiac torso phantom with an internal calibration source was designed with various heart-to-calibration ratios (HCRs) simulating different levels of a patient's uptake. SPECT acquisitions of the phantom were performed using optimized acquisition and processing parameters for (123)I cardiac SPECT. HCRs were calculated using planar projection and tomographic reconstructions. The paired t-test and regression analysis were used to compare the HCRs given by different calculation methods. RESULTS: SPECT produced more accurate HCRs than planar imaging. The slopes of the regression lines for SPECT using filtered back-projection were statistically significantly higher than those for planar imaging (0.2118 +/- 0.0297 vs. 0.0819 +/- 0.0070, P = 0.0001). 2-D DSP and 3-D DSP yielded similar HCRs that were close to the true HCR. The slopes of the regression lines for 2-D DSP and 3-D DSP were 0.9203 +/- 0.0523 and 0.9101 +/- 0.0304, respectively. The DSP HCRs were significantly more accurate than those calculated without DSP (P < 0.0001). CONCLUSION: DSP significantly improves quantification in (123)I cardiac SPECT imaging. 2-D DSP with its less computational burden shows promise for implementation in clinical practice so as to allow the use of the widely available low-energy, high-resolution collimators for quantitative I cardiac SPECT imaging.

Algorithms↗

99mTc-MAG3 renography: normal values for MAG3 clearance and curve parameters, excretory parameters, and residual urine volume.

OBJECTIVE: Specific quantitative measurements have been recommended to assist in the interpretation of technetium-99m mercaptoacetyltriglycine (MAG3) renal studies. Our objective was to define the sex- and age-specific normal ranges for these recommended parameters. MATERIALS AND METHODS: Data were obtained from a retrospective analysis of 106 subjects who were evaluated for kidney donation. The MAG3 clearance was calculated using a common camera-based method. The relative uptake, prevoid/postvoid and postvoid/maximum count ratios were determined using whole-kidney regions of interest (ROIs). Time to peak, time to half-peak, 20 min/maximum and 20 min/2-3 min count ratios were determined for cortical and whole-kidney ROIs. Residual urine volume was calculated on the basis of the pre- and postvoid bladder counts and voided urine volume. RESULTS: The mean camera-based MAG3 clearance was 321 +/- 69 mL/min/1.73 m2, essentially the same as the mean plasma sample MAG3 clearance in comparable populations. The percentages of relative uptake in the right and left kidneys were 49% and 51% +/- 4%, respectively; no difference was seen between men and women. Cortical values were lower than the whole-kidney values (p < 0.001); the mean cortical 20 min/maximum count ratio was 0.19 (SD, 0.07 and 0.04 for right and left kidneys, respectively). The mean postvoid/maximum whole-kidney count ratio was < 0.1, and the mean postvoid residual bladder volume was < 30 mL. CONCLUSION: Normal limits adjusted for age and sex have been established. Applying normal ranges to quantitative MAG3 parameters may assist in the interpretation of MAG3 scintigraphy and facilitate appropriate patient management.

Adult↗

RENEX: an expert system for the interpretation of 99mTc-MAG3 scans to detect renal obstruction.

UNLABELLED: A renal expert system (RENEX) has been developed to assist physicians detect renal obstruction in patients undergoing pre- and postfurosemide 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) scans. RENEX uses quantitative parameters extracted from the dynamic renal scan data and heuristic rules in the form of a knowledge base (KB) obtained from expert interpreters to conclude whether a kidney is obstructed. METHODS: Normal limits were established for 47 quantitative parameters extracted from the 99mTc-MAG3 scans of 100 potential renal donors. From these data the domain expert estimated 5 boundary conditions for each parameter: (i) definitely abnormal, (ii) probably abnormal, (iii) equivocal, (iv) probably normal, and (v) definitely normal. A sigmoid-type curve was then generated from these 5 boundary conditions, creating a parameter knowledge library used for converting the value of a prospective patient's individual quantitative parameters to a certainty factor (CF). Sixty heuristic rules were extracted from the domain expert to generate the KB for detecting obstruction. A forward-chaining inference engine was developed using the MYCIN combinatories (an approximation of Bayes theorem) to determine obstruction. A justification engine was implemented, which recorded the sequence of each rule that was fired and the current CF value of all input and output parameters at the time of instantiation to track and justify the logic of the conclusions. The entire system was fine tuned and tested using a pilot group of 32 patients (11 males, 21 females; mean age, 56.8 +/- 17.2 y; 63 kidneys) deemed by an expert panel to have 41 unobstructed kidneys, 13 obstructed kidneys,and 9 equivocal findings. RESULTS: RENEX agreed with the expert panel in 92% (12/13) of the obstructed kidneys, 93% (38/41) of the unobstructed kidneys, and 78% (7/9) of the kidneys interpreted as equivocal for obstructions. Processing time per patient was practically instantaneous using a 3.0-GHz personal computer programmed using interactive data language. CONCLUSION: We have developed a renal expert system for detecting renal obstruction using pre- and postfurosemide 99mTc-MAG3 renal scans, at a standardized expert level. These encouraging preliminary results warrant a prospective study in a large population of patients with and without renal obstruction to establish the diagnostic performance of this system.

Expert Systems↗

Correspondence between left ventricular 17 myocardial segments and coronary arteries.

AIMS: The last guidelines recommend a standardized 17-segment model for tomographic imaging of the left ventricle. The aim of this study is to analyse the correspondence of the 17 left ventricular segments with each coronary artery by myocardial perfusion SPECT studies. METHODS AND RESULTS: Fifty patients selected for percutaneous revascularization of one coronary artery [24 left anterior descending (LAD), 15 right coronary artery (RCA), and 11 left circumflex (LCX)] were included. The (99m)Tc-labelled compound was injected immediately after the inflation of the balloon during percutaneous coronary angioplasty. At least 90 s of complete occlusion time was required. Maximal contour of regions of hypoperfusion corresponding to each coronary artery occlusion were delineated over the polar map of 17 segments. Nine segments corresponded to only one coronary artery: eight to LAD (basal anterior, basal anteroseptal, mid-anterior, mid-anteroseptal, apical anterior, apical septal, apical lateral, and apex) and one to LCX (basal anterolateral). Basal inferoseptal, mid-inferoseptal, and apical inferior segments could correspond to LAD or RCA. Basal inferior, basal inferolateral, mid-inferior, and mid-inferolateral segments could correspond to RCA or LCX, whereas the mid-anterolateral segment could correspond to LAD or LCX. CONCLUSION: The most specific segments (anterior, anteroseptal, and all apical segments except the infero-apical) correspond to LAD but no segment can be exclusively attributed to the RCA. Inferoseptal segments can be attributed to LAD or RCA, inferior and inferolateral segments to RCA or LCX, and mid-anterolateral segment to LAD or LCX.

Angioplasty, Balloon, Coronary↗

Assessment of cardiac wall motion and ejection fraction with gated PET using N-13 ammonia.

BACKGROUND: Cardiac gating is not routinely used in cardiac positron emission tomography (PET). The aim of this study was to determine the feasibility of assessing regional wall motion, ejection fraction (EF), cardiac volumes, and mass with nitrogen-13 ammonia (N-13 ammonia) at the time of PET myocardial perfusion imaging. METHODS: We studied 12 healthy volunteers (mean age, 28 +/- 8 years) and 53 patients with documented coronary artery disease (CAD) (mean age, 59 +/- 11 years). All subjects received a single administration of approximately 600 MBq (16 mCi) of N-13 ammonia intravenously. A 6-minute dynamic scan was performed for quantitative assessment of myocardial perfusion at rest, followed by a separate, 13-minute static scan acquired in the gated mode (8 equal bins). Gated data was imported into the Emory Toolbox. Wall motion was evaluated by dividing the myocardium into 9 anatomic regions graded semiquantitatively. RESULTS: Healthy volunteers had a normal EF (61 +/- 6), end systolic volume (ESV) (37 +/- 15 mL), end diastolic volume (EDV) (89 +/- 25 mL), and cardiac mass (116 +/- 18 g). In contrast, patients with CAD showed reduced EF (32 +/- 13%) and increased ESV (129 +/- 56 mL), EDV (188 +/- 68 mL), and cardiac mass (173 +/- 45 g) (P < 0.001 for each). In patients with CAD, EF measured by gated PET correlated significantly to independent measurements of EF (P < 0.001). CONCLUSIONS: Gating of cardiac perfusion images obtained after administration of N-13 ammonia is feasible and appears to be an accurate means of evaluating regional and global cardiac function. Gating can provide important additional diagnostic and prognostic information.

Adult↗

Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation.

UNLABELLED: Clinical decisions regarding diagnosis and effective treatment of coronary artery disease frequently require integration of information from various imaging modalities, which are acquired, processed, and read at different physical locations and times. We have developed methods to integrate the information in 2 cardiac imaging studies, perfusion SPECT and coronary angiography. Three-dimensional (3D) models of the coronary artery tree created from biplane angiograms were automatically aligned with 3D models of the left ventricular epicardial surface created from perfusion SPECT. Myocardial mass at risk was used as a unique measure to validate the accuracy of the unification. METHODS: Thirty patients were injected with the perfusion agent (99m)Tc-tetrosfosmin during balloon occlusion while undergoing percutaneous transluminal coronary angioplasty for single-vessel coronary artery disease. Thus, a single, severe perfusion defect was induced by a single coronary artery occlusion of known severity and placement. The accuracy of the unification was measured by computing the overlap between physiologic area at risk, determined using SPECT perfusion quantification techniques only, and anatomic area at risk, determined using coronary artery anatomy aligned with the epicardial surface of the left ventricle. RESULTS: The unification resulted in an 80% overlap of areas at risk, and an overlap of 84% of normal areas, for all coronary artery distributions. The mass at risk measured based on the unified anatomic information correlated with the physiologically based mass at risk as y = 0.92x + 10.3 g; r = 0.76, SEE = 10.4 g. CONCLUSION: A unification algorithm for automatically registering 3D models of the epicardial surface from perfusion SPECT and 3D coronary artery trees from coronary angiography has been presented and validated in 30 patient studies.

Algorithms↗

Optimized acquisition and processing protocols for I-123 cardiac SPECT imaging.

BACKGROUND: Deconvolution of septal penetration (DSP) has been developed to improve quantification so as to allow the use of low-energy high-resolution collimators for iodine 123 cardiac single photon emission computed tomography (SPECT) imaging. The purpose of this study is to optimize its acquisition and processing protocols. METHODS AND RESULTS: Planar images of a 9-compartment phantom loaded with variable radioactive concentrations were acquired to derive optimal scatter compensation scaling factors for 20% and 15% photopeak energy window configurations, respectively. A cardiac phantom, loaded with high and low heart-to-calibration ratios (HCRs), respectively, was imaged with both configurations. Repeated acquisitions were done for medium-energy all-purpose collimators for comparison. Critical frequencies for Butterworth filtering were optimized by use of defect contrast and normal short-axis uniformity as selection indices. HCRs were calculated with planar projection and different reconstruction methods, respectively, and then compared with the true HCRs. SPECT produced more accurate HCRs than planar imaging. With the optimized parameters for scatter compensation and filtering, the 2 energy window configurations yielded similar results. Iterative reconstructions with DSP yielded more accurate HCRs than other reconstructions without DSP. CONCLUSION: The optimized protocols based on DSP show promise that quantification of I-123 cardiac SPECT imaging can be achieved with the widely available low-energy high-resolution collimators.

Algorithms↗

Quantitative Tc-99m sestamibi attenuation-corrected SPECT: development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population.

BACKGROUND: A gender-independent stress normal database and criteria for abnormality for attenuation-corrected rest-stress technetium 99m sestamibi same-day myocardial perfusion imaging were developed by evaluation of 112 patients, validated against an obese population of 95 patients from four different clinical sites, and compared with conventional gender-matched database quantification of non-attenuation-corrected studies. METHODS AND RESULTS: These 95 validation patients (63 men) were used for prospective quantitative evaluation (mean weight, 213 +/- 57 lb; mean body mass index, 32 +/- 9 kg/m(2)). This group included 21 patients (12 men) with a lower than 5% likelihood of coronary artery disease (mean weight, 226 +/- 72 lb; mean body mass index, 34 +/- 13 kg/m(2)) and 74 who underwent cardiac catheterization within 2 months (35 with normal coronaries or coronary lesions <70%). These studies were processed twice, once by use of conventional reconstruction and gender-specific database quantification and a second time by use of attenuation correction and a single gender-independent attenuation-corrected normal database. The attenuation-corrected normal database and criteria for abnormality were developed by evaluation of 48 and 78 patients, respectively. No statistically significant differences were found when comparing attenuation-corrected perfusion distributions of normal men and women, whereas significant differences were found in the same uncorrected studies. Compared with quantitative analysis of the uncorrected studies, quantitative analysis of the attenuation-corrected studies by use of a gender-independent normal database demonstrated a significant improvement in normalcy rate (90% vs 52%, P =.006) and specificity (57% vs 29%, P =.015) in this obese population at no significant loss in sensitivity (90% vs 97%, P = not significant). CONCLUSION: Attenuation-corrected studies can be quantified with a single gender-independent normal database and a single criterion for abnormality without loss of sensitivity and with significantly better specificity and normalcy rate.

Coronary Artery Disease↗

Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging.

BACKGROUND: Attenuation artifact remains a substantial limitation to confident interpretation of images and reduces laboratory efficiency by requiring comparison of stress and rest image sets. Attenuation-corrected stress-only imaging has the potential to ameliorate these limitations. METHODS AND RESULTS: Ten experienced nuclear cardiologists independently interpreted 90 stress-only electrocardiography (ECG)-gated technetium 99m sestamibi images in a sequential fashion: myocardial perfusion imaging (MPI) alone, MPI plus ECG-gated data, and attenuation-corrected MPI with ECG-gated data. Images were interpreted for diagnostic certainty (normal, probably normal, equivocal, probably abnormal, abnormal, and perceived need for rest imaging). With stress MPI data alone, only 37% of studies were interpreted as definitely normal or abnormal, with a very high perceived need for rest imaging (77%). The addition of gated data did not alter the interpretations. However, attenuation-corrected data significantly increased the number of studies characterized as definitely normal or abnormal (84%, P <.005) and significantly reduced the perceived need for rest imaging (43%, P <.005). These results were confirmed by use of a nonsequential consensus interpretation of three readers. CONCLUSION: Attenuation correction applied to studies with stress-only Tc-99m ECG-gated single photon emission computed tomography images significantly increases the ability to interpret studies as definitely normal or abnormal and reduces the need for rest imaging. These findings may improve laboratory efficiency and diagnostic accuracy.

Adult↗

Incremental prognostic value of left ventricular function by myocardial ECG-gated FDG PET imaging in patients with ischemic cardiomyopathy.

BACKGROUND: The purpose of this study was to determine the independent value of left ventricular (LV) functional parameters derived from gated fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) to predict prognosis in patients with ischemic cardiomyopathy undergoing myocardial viability assessment. METHODS AND RESULTS: We studied 90 consecutive patients with coronary artery disease and low LV ejection fraction (26% +/- 7%) undergoing gated FDG PET to assess myocardial viability for potential revascularization. The primary endpoint for this analysis was the occurrence of cardiac death, myocardial infarction, or worsening heart failure (HF) to New York Heart Association class IV. During follow-up (22 +/- 14 months), 21 patients had an event (17 died, 4 had myocardial infarctions, and 4 had worsening HF). On Cox regression analysis, the event-free survival rate at 2 years was lower for patients with an end-diastolic volume (EDV) of 260 mL or greater (relative risk, 2.7; P = .014), end-systolic volume (ESV) of 200 mL or greater (relative risk, 2.5; P = .021), and LV mass of 143 g or greater (relative risk, 1.6; P = .009). In a risk-adjusted model, EDV (chi 2 = 68, P < .0001) and ESV (chi 2 = 75, P = .035) added a significant amount in the estimation of events over the perfusion-FDG mismatch pattern (chi 2 = 40, P < .001). In a stratified Cox model, patients with PET mismatch, LV ejection fraction lower than 25%, and EDV of 260 mL or greater had the lowest survival rate (P = .006). These patients showed an apparent survival benefit with revascularization but without an improvement in HF symptoms. CONCLUSION: LV functional parameters determined by gated FDG PET have incremental prognostic value over viability information in patients with ischemic cardiomyopathy. Our data suggest that patients with residual viability and advanced cardiac remodeling are at high clinical risk. In these patients the apparent survival benefit of revascularization may not be associated with a measurable improvement in HF symptoms.

Cardiomyopathies↗

Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index.

BACKGROUND: Obesity is a growing problem in the United States, and attenuation artifacts are more prevalent in this patient group. This study evaluated the impact of attenuation correction in patients with a high body mass index (BMI). METHODS AND RESULTS: Three readers interpreted gated attenuation-corrected and non-attenuation-corrected rest/stress technetium 99m sestamibi myocardial perfusion imaging results in 116 patients (BMI <30, n = 60; BMI > or =30, n = 56) who had coronary angiography no more than 60 days after imaging. Readers were blinded to all clinical information and as to whether myocardial perfusion imaging was attenuation-corrected or non-attenuation-corrected. Sensitivity, specificity, and accuracy for detection of coronary artery disease of 70% or greater for attenuation-corrected versus non-attenuation-corrected single photon emission computed tomography (SPECT) were 86% versus 89%, 79% versus 50%, and 84% versus 79%, respectively. Sensitivity, specificity, and accuracy for attenuation-corrected versus non-attenuation-corrected SPECT for patients with BMI less than 30 were 90% versus 90%, 82% versus 64%, and 88% versus 85%, respectively. For BMI of 30 or greater, the results were 82% versus 87%, 76% versus 41%, and 80% versus 73%, respectively. There was a significant difference in specificity overall ( P = .02) and for the category of BMI of 30 or greater ( P = .03). CONCLUSIONS: This study demonstrates that electrocardiography-gated attenuation-corrected Tc-99m sestamibi SPECT myocardial perfusion imaging improves specificity compared with electrocardiography-gated non-attenuation-corrected SPECT myocardial perfusion imaging, especially in patients with BMI of 30 or greater.

Artifacts↗

Detecting changes in serial myocardial perfusion SPECT: a simulation study.

BACKGROUND: New algorithms were evaluated for their efficacy in detecting and quantifying serial changes in myocardial perfusion from single photon emission computed tomography (SPECT). METHODS AND RESULTS: We generated 72 simulations with various left ventricular positions, sizes, count rates, and perfusion defect severities using the nonuniform rational B-splines (NURBs)-based CArdiac Torso (NCAT) phantom. Images were automatically aligned by use of both full linear and rigid transformations and quantified for perfusion by use of the CEqual program. Changes within a given perfusion defect were compared by use of a Student t test before and after registration. Registration approaches were compared by use of receiver operating characteristic analysis. Changes of 5% were not detected well in single patients with or without alignment. Changes of 10% and 15% could be detected with false-positive rates of 15% and 10%, respectively, in single studies if alignment was performed before perfusion analysis. Alignment also reduced the number of studies necessary to demonstrate a significant perfusion change (P < .05) in groups of patients by about half. CONCLUSION: Comparison of mean uptake by t values in SPECT perfusion defects can be used to detect 10% and greater differences in serial perfusion studies of single patients. Image alignment is necessary to optimize automatic detection of perfusion changes in both single patients and groups of patients.

Computer Simulation↗

Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control.

BACKGROUND: Small-field-of-view (FOV) dedicated cardiac single photon emission computed tomography (SPECT) systems will frequently exhibit severe transmission scan truncation that may degrade attenuation correction (AC). This study evaluated the impact of transmission scan truncation on AC and developed automated transmission scan truncation quality control (ATSTQC) for small-FOV systems. METHODS AND RESULTS: Small-FOV data were simulated from the data of 10 patients acquired by a full-FOV Philips Vertex system. AC images of the full- and small-FOV data were compared by mean and maximum absolute differences of myocardial counts, and differences in stress and rest severity scores were calculated by use of the Emory Cardiac Toolbox.small-FOV systems. ATSTQC was developed to identify critical truncation that significantly increased these indices and then tested with 18 independent patients. Left-side truncation resulted in significant distortion of the quantitative indices. ATSTQC, developed on the condition that left-side truncation is critical, showed high concordance with the qualitative assessment in identification of critical truncation. CONCLUSIONS: Identification of left-side truncation as critical truncation is necessary to judge whether accurate AC can be obtained. The developed ATSTQC can accurately detect critical truncation and will help clinicians decide whether to use AC in a particular study.

Artifacts↗

Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony.

BACKGROUND: A count-based method using technetium-99m sestamibi electrocardiography-gated myocardial perfusion single photon emission computed tomography imaging has been developed to extract the left ventricular (LV) regional phase of contraction (onset of mechanical contraction [OMC]) throughout the cardiac cycle. This study was performed to develop OMC normal databases and dynamic OMC displays for assessment of cardiac mechanic dyssynchrony. METHODS AND RESULTS: LV regional phases were extracted from 90 enrolled normal subjects (45 men and 45 women) by use of the Emory Cardiac Toolbox and then submitted to statistical analysis to generate the normal databases. The LV OMC wave was dynamically propagated over the perfusion polar map by blackening either sequential phase bins or all past phases. The developed OMC normal databases consisted of peak phase (134.5 degrees +/- 14.3 degrees for men and 140.2 degrees +/- 14.9 degrees for women), phase SD (14.2 degrees +/- 5.1 degrees for men and 11.8 degrees +/- 5.2 degrees for women), and phase histogram bandwidth (38.7 degrees +/- 11.8 degrees for men and 30.6 degrees +/- 9.6 degrees for women), skewness (4.19 +/- 0.68 for men and 4.60 +/- 0.72 for women), and kurtosis (19.72 +/- 7.68 for men and 23.21 +/- 8.16 for women). Both statistical analysis and dynamic OMC displays were incorporated into a user interface as a diagnostic tool. CONCLUSION: The OMC normal databases and dynamic OMC displays should help clinicians evaluate cardiac mechanic dyssynchrony. Prospective clinical trials are needed to validate whether this tool can be used to select patients with severe heart failure symptoms who might benefit from cardiac resynchronization therapy.

Databases, Factual↗

Automated quality control of emission-transmission misalignment for attenuation correction in myocardial perfusion imaging with SPECT-CT systems.

BACKGROUND: Emission-transmission misalignment with single-photon emission computed tomography (SPECT)-computed tomography (CT) systems can impair attenuation correction (AC) in myocardial perfusion imaging. This study was performed to develop automated quality control (Auto-QC) to detect critical misalignment that can significantly impact AC. METHODS AND RESULTS: Auto-QC was developed to segment myocardium and mediastinum from emission and transmission reconstructions, respectively. Myocardium-mediastinum mismatch was used as the quality-control index (QCI). The QCI threshold for acceptable AC was determined with NCAT (NURBS [nonuniform rational B-spline]-based cardiac torso phantom) simulation and verified with 2 patients with minimal misalignment. Compromised data sets, generated by shifting the attenuation maps by 0.5, 1.0, 1.5, and 2.0 pixels along left-right, up-down, and head-foot directions, respectively, were qualitatively and quantitatively compared with the unshifted data sets. Auto-QC was tested with the 2 verification patients and 41 additional patients. Shifts by more than 1 pixel along any direction compromised AC. Auto-QC with the QCI threshold (3%) had highly concordant results with manual quality control in the detection of critical misalignment (sensitivity of 88% and 90% and specificity of 93% and 95% for the tests by use of the 2 verification patients and 41 additional patients, respectively). CONCLUSION: QCI quantitatively represented the severity of misalignment. Auto-QC can help clinicians be aware of critical misalignment and can assist in realignment of SPECT and CT images.

Algorithms↗