Gadolinium-enhanced 3D MR angiography of pulmonary hypoplasia and aplasia.
OBJECTIVE: The goal of this study was to determine the role of gadolinium-enhanced 3D MR angiography (MRA) in patients with suspected pulmonary hypoplasia and aplasia in a retrospective analysis of MRA and digital subtraction angiography in 11 patients with clinical and/or radiologic suspicion of pulmonary hypoplasia and aplasia. CONCLUSION: Gadolinium-enhanced 3D MRA is capable of diagnosing pulmonary hypoplasia and aplasia rapidly and accurately. Both pulmonary hypoplasia and aplasia can be shown morphologically in a noninvasive manner, obviating digital subtraction angiography.
Focusing on the ethnobotanical uses of plants in Mersin and Adana provinces (Turkey).
This paper presents the result of a study on the herbal drugs in the herbal markets in Mersin and Adana. The data were collected through direct interviews with herbalists and customers between 2002-2005 and the popular medicinal plants were investigated. A total of 107 species belonging to 56 families were investigated and the samples were listed with their local and Latin names. The investigation includes cross-checking the disorders and their herbal cures and their recommended use stated by the local herbalists, by the parts used, and by the preparations. The cultivated species and their ethno botanical uses, are documented and extensive inventory is presented. As a result, we observed that these plants are used especially for intestinal digestive disorders of the gastrointestinal tract, (21.68%), respiratory tract system disorders (10.43%), heart-blood circulatory system disorders (8.48%), urinary tract system disorders (7.70%), skin disorders (6.48%) and others.
A case of hemangiosarcoma in thyroid with severe anemia due to bone marrow metastasis.
A 56-year-old woman presented with rapidly enlarging thyroid mass and deep anemia. There was no history of gastrointestinal bleeding, and endoscopic examinations of the gastrointestinal system were normal. Fine needle aspiration cytology from the thyroid nodule was suspicious. After blood transfusion, total thyroidectomy was performed. Postoperative histopathological examination of the specimen revealed hemangiosarcoma of the thyroid. After establishment of the diagnosis chemotherapy was started. But hemoglobin values decreased again and hepatosplenomegaly developed at the second month of surgery. Bone marrow aspiration cytology which was performed demonstrated the same tumoral cells infiltrating bone marrow. The patient died at 12th week after surgery. Thyroid hemangiosarcoma can metastasize to the bone marrow and anemia may be an indicator of the advanced disease. In the differential diagnosis of the anemia, bone marrow metastasis and bone marrow biopsy should be considered in suspected cases.
Type I proatlantal artery with bilateral absence of the external carotid arteries.
During color Doppler examination of a 41-year-old man who presented with vertigo, a right vertebral artery could not be found. Both MR angiography and digital subtraction angiography revealed a large anastomotic vessel between the right internal carotid and vertebral artery. It was thought to be type I proatlantal artery. Furthermore, the external carotid arteries were bilaterally absent. Although each vascular anomaly mentioned above is rare, it even more rare for these variations to occur simultaneously.
Soft-tissue masses: use of a scoring system in differentiation of benign and malignant lesions.
The purpose of this study was to show the qualitative and quantitative MRI characteristics of soft-tissue masses in differentiation of benign and malignant lesions. A total of 90 soft-tissue lesions were reviewed in this study. The scoring system presents a more objective diagnostic performance in the prediction of benign or malignant masses. With the use of this scoring system, unnecessary biopsy can be precluded in benign lesions.
How image quality can be improved: our experience with multidetector computed tomography coronary angiography.
PURPOSE: The objective of this study was to investigate the factors that may influence image quality on multidetector computed tomography (MDCT) coronary angiography (CA). MATERIALS AND METHODS: Two hundred twenty-four consecutive patients (161 men and 63 women; mean age, 52 years; age range, 34-76 years) evaluated with MDCT CA were included in the study. The evaluation of the quality of the patients' images was mainly based on the contrast material phase (early phase, optimal phase, or late phase) and the level of stepladder artifact (none, acceptable, or unacceptable). In addition, factors such as patient selection, patient preparation, scanning, processing, and steps of analysis, which may be affecting the quality of a final image, were examined independently. RESULTS: Patients who could not achieve sufficient breath-holding despite multiple breath exercises, those with a calcium score of 500 or higher, those with a heart rate greater than 90 bpm after metoprolol administration (because of shortening of the diastolic phase in the most still period), and those whose scanning was not completed were excluded from the study. The results for the remaining 224 patients were evaluated. Based on the contrast phase, there were 66 (29.5%) patients in the first group (early), 93 (41.5%) in the second group (optimal), and 65 (29%) in the third group (late). Among the 224 patients, the images of 152 (67.9%) had no stepladder artifact, those of 67 (29.9%) were of acceptable image quality, and those of 5 (2.2%) were of unacceptable image quality. CONCLUSION: It is important to obtain high-quality images to achieve correct interpretation with coronary artery CT angiography. This study aimed to describe a technique performed on 224 patients based on an array of factors ranging from patient selection to postprocessing. The results show that patient selection, cooperation with the patient, and breath-holding exercises play a very important role in obtaining the best images. In addition, a proper scanning technique (e.g., placement of electrocardiographic electrodes and contrast material phase) and postprocessing (e.g., reconstruction interval) may also contribute to obtaining high-quality images.